Solar photovoltaic (PV) systems in buildings must comply with both electrotechnical standards for module safety and local building codes, which typically do not address their electrical nature. This regulatory gap creates challenges in assessing the fire performance of PV systems. This paper presents a procedure to adapt a common test method used in some building codes to assess external fire conditions for roofs, while maintaining operative PV modules. Two configurations were tested: an organic PV thin film on a metallic sandwich panel and a glass–glass-encapsulated organic PV module. The tests were conducted under high voltage and current conditions to simulate the systems’ behavior within a larger PV array. Significant electric arcs were observed during testing of the metallic sandwich panel configuration without glass protection when subjected to high voltages or currents. In these cases, total heat release increased by at least 30% compared to non-electrically loaded scenarios or glass-insulated PV modules, likely due to a greater damaged surface area. Electric arcs created new ignition sources, damaging whole PV modules, whereas in the case with no electrical load, propagation flames advanced toward both the upper edge and the corners of the sample, ultimately damaging the entire triangular area above the fire source. The results indicate that the electrical characteristics of PV systems can significantly impact external fire spread behavior. The study identifies challenges in maintaining system activity during testing and simulating real scenarios and proposes for future research directions.
The use of innovative insulating materials can contribute to an energy-efficient design by improving the thermal performance of building envelopes while also reducing the embodied energy of materials. Ultra-low carbon steel envelope solutions with bio-based insulations are aligned with this approach. However, fire safety aspects in general and smoldering issues in particular need to be considered when using bio-based insulations. Accordingly, this paper proposes a system-level assessment of the fire performance of steel envelopes with bio-based insulations, not only identifying potential smoldering issues of the core material but also defining and evaluating strategies that could address these concerns within the system design. For this purpose, the variables that could affect the fire performance of wood fiber insulation sandwich panels were identified while considering the different stages of the smoldering phenomena, such as the influence of the joint design or mounting provisions for the initiation, the existence of air cavities, oxygen entrances or physically continuous materials with a tendency to smolder for the continuation, or the inclusion of limiting elements or mitigation layers for spread limitation. Finally, strategies for fire-safe enclosures using bio-based insulations are proposed, assuming smoldering affections in wood-derived materials and analyzing possible mitigation elements at the system level.
This article focuses on the fire safety risks associated with conventional glass–aluminum façades—with a particular focus on stick and unitized curtain walling systems—providing an overview of possible fire spread mechanisms, considering the role of the curtain wall in maintaining compartmentation at the spandrel zone. First, it analyzes some of the relevant requirements of different European building regulations. Then, it provides a test evidence-based critical analysis of the gaps and loopholes in the relevant fire resistance standard for partial curtain wall configurations (EN 1364-4), where the evaluation of the propagation within the façade system is not necessarily considered in the fire-resistant spandrel zone. Finally, it presents a proposal for addressing these gaps in the form of a theoretical concept for a new test configuration and additional assessment criteria. This is followed by an initial experimental analysis of the concept. The standard testing campaign showed that temperature rise in mullions can exceed 180 °C after 30 min if limiting measures are not considered in the façade design. However, this can be only detected if framing is in the non-exposed area of the sample, being part of the evaluation surface. Meanwhile, differences are detected between the results from standard and new assessment criteria in the new configuration proposed, including a more rapid temperature rise for framing elements (207 K in a second level mullion at minute 90) than for the common non-exposed assessment surface of the sample (172 K at the same time) in cases where cavities are not protected. Accordingly, the proposed configuration successfully detected vertical temperature transfer within mullions, which can remain undetected in standard EN 1364-4 tests, highlighting the potential for fire spread even in EI120-rated assemblies.