Context The normal cortisol response 30 or 60 minutes after cosyntropin (ACTH[1–24]) is considered to be ≥18 μg/dL (500 nmol/L). This threshold is based on older serum cortisol assays. Specific monoclonal antibody immunoassays or LC-MS/MS may have lower thresholds for a normal response. Objective To calculate serum cortisol cutoff values for adrenocorticotropic hormone (ACTH) stimulation testing with newer specific cortisol assays. Methods Retrospective analysis of ACTH stimulation tests performed in ambulatory and hospitalized patients suspected of adrenal insufficiency (AI). Serum samples were assayed for cortisol in parallel using Elecsys I and Elecsys II immunoassays, and when volume was available, by Access immunoassay and LC-MS/MS. Results A total of 110 patients were evaluated. Using 18 μg/dL as the cortisol cutoff after ACTH stimulation, 14.5%, 29%, 22.4%, and 32% of patients had a biochemical diagnosis of AI using the Elecsys I, Elecsys II, Access, and LC-MS/MS assays, respectively. Deming regressions of serum cortisol were used to calculate new cortisol cutoffs based on the Elecsys I cutoff of 18 μg/dL. For 30-minute values, new cutoffs were 14.6 μg/dL for Elecsys II, 14.8 μg/dL for Access, and 14.5 μg/dL for LC-MS/MS. Baseline cortisol <2 μg/dL was predictive of subnormal stimulated cortisol values. Conclusion To reduce false positive ACTH stimulation testing, we recommend a new serum cortisol cutoff of 14 to 15 μg/dL depending on the assay used (instead of the historical value of 18 μg/dL with older polyclonal antibody assays). Clinicians should be aware of the new cutoffs for the assays available to them when evaluating patients for AI.
1 October 2009 in The Journal of Clinical Endocrinology & Metabolism
Context: The measurement of cortisol in saliva is a simple, reproducible, and reliable test to evaluate the normal and disordered control of the hypothalamic-pituitary-adrenal (HPA) axis. There are a variety of simple methods to obtain saliva samples without stress, making this a robust test applicable to many different experimental and clinical situations. Evidence Acquisition: Ovid Medline and PubMed from 1950 to present were searched using the following strategies: [;and;and;] and [;and;and;]. The bibliographies of all relevant citations were evaluated for any additional appropriate citations. Evidence Synthesis: Measurement of an elevated late-night (2300 to 2400 h) salivary cortisol has a greater than 90% sensitivity and specificity for the diagnosis of endogenous Cushing’s syndrome. Late-night salivary cortisol measurements are also useful to monitor patients for remission and/or recurrence after pituitary surgery for Cushing’s disease. Because it is a surrogate for plasma free cortisol, the measurement of salivary cortisol may be useful during an ACTH stimulation test in patients with increased plasma binding protein concentrations due to increased estrogen, or decreased plasma binding protein concentrations during critical illness. Most reference laboratories now offer salivary cortisol testing. Conclusions: It is expected that the use of the measurement of salivary cortisol will become routine in the evaluation of patients with disorders of the HPA axis. Late-night salivary cortisol is an excellent measurement for diagnosis of Cushing’s syndrome, and follow-up of patients after surgical treatment of Cushing’s disease.
The physiological control of cortisol synthesis in the adrenal cortex involves stimulation of adrenocorticotrophic hormone (ACTH) by hypothalamic corticotrophin‐releasing hormone (CRH) and then stimulation of the adrenal by ACTH. The control loop of the hypothalamic–pituitary–adrenal (HPA) axis is closed by negative feedback of cortisol on the hypothalamus and pituitary. Understanding this system is required to master the diagnosis, differential diagnosis and treatment of endogenous hypercortisolism – Cushing's syndrome. Endogenous Cushing's syndrome is caused either by excess ACTH secretion or by autonomous cortisol release from the adrenal cortex. Diagnosis of cortisol excess exploits three physiological principles: failure to achieve the normal nadir in the cortisol diurnal rhythm, loss of sensitivity of ACTH‐secreting tumours to cortisol negative feedback, and increased excretion of free cortisol in the urine. Differentiating a pituitary source of excess ACTH (Cushing's disease) from an ectopic source is accomplished by imaging the pituitary and sampling for ACTH in the venous drainage of the pituitary. With surgical removal of ACTH or cortisol‐secreting tumours, secondary adrenal insufficiency ensues because of the prior suppression of the HPA axis by glucocorticoid negative feedback. Medical therapy is targeted to the anatomical location of the dysregulated component of the HPA axis. Future research will focus on new diagnostics and treatments of Cushing's syndrome. These are elegant examples of translational research: understanding basic physiology informs the development of new approaches to diagnosis and treatment. Appreciating pathophysiology generates new areas for inquiry of basic physiological and biochemical mechanisms.
1 December 2007 in European Journal of Endocrinology
Objective: Cushing's syndrome (CS) is difficult to diagnose due to its nonspecific presentation. Diagnostic tests like 24-h urine free cortisol (UFC) and the overnight 1 mg dexamethasone suppression test (DST) lack sufficient sensitivity and specificity. Measurement of nocturnal salivary cortisol (NSC) is an accurate and reproducible test with a high sensitivity for CS. However, its performance in mild CS has not been reported. We present 11 cases of CS with normal or mildly elevated UFC in whom NSC was helpful in making a diagnosis.Design and methods: All patients had at least one collection of 24-h UFC and NSC and eight had an overnight 1 mg DST. The number of NSC measurements per patient was determined by the clinical index of suspicion and the results of initial testing. Imaging studies included magnetic resonance imaging (MRI) of pituitary or computer tomography scan of abdomen.Results: Only four out of eleven patients had elevations in UFC and none were >2 times the upper limit of normal. Seven out of eight had an abnormal DST. All patients had some elevated NSCs (14–100%). Out of eleven patients, six had an abnormality in the pituitary gland found by MRI and two out of eleven had adrenal masses. The remaining three had normal pituitary MRI but had inferior petrosal sinus (IPS) sampling indicating Cushing's disease. All patients had appropriate surgery, and histopathology of all except one was suggestive of either a cortisol-producing adrenal adenoma or an ACTH-secreting pituitary adenoma.Conclusion: Neither a normal UFC nor a normal NSC excludes mild CS. Multiple samples (urine/saliva) and DST are needed to make the diagnosis of mild CS.