Vladimira Rimac

Dr. Vladimira Rimac

University Hospital Centre Zagreb, Zagreb, Zagreb, Grad, Croatia

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 February 2018 in Laboratory Medicine
Verified
Journal Article
Closed access
PDF file
VRVladimira Rimac
Vladimira Rimac
ILIvana Lapic
Ivana Lapic
KKKresimir Kules
Kresimir Kules
DRDunja Rogic
Dunja Rogic
MMMarijana Miler
Marijana Miler
Autovalidation algorithm should be properly designed with clearly defined criteria and any data that do not meet the criteria, must be reviewed and manually validated. The aim was to define the rules for autovalidation in our laboratory information system (LIS), and validate the algorithm prior to its implementation in routine laboratory work. Autovalidation was implemented for all routine serum biochemistry tests. The algorithm included analytical measurement ranges (AMR), delta check, critical values, serum indices and all preanalytical and analytical flags from the analyzer. In the validation process 9805 samples were included, and 78.3% (7677) of all samples were autovalidated. The highest percentage of non-validated samples (54.9%) refers to those with at least one result outside the method linearity ranges (AMR criteria) while critical values were observed to be the least frequent criterion for stopping autovalidation (1.8%). Also, 38 samples were manually validated as they failed to meet the autovalidation criteria. Implementation of algorithm for autovalidation in our institution resulted in the redesign of the existing LIS. This model of the autovalidation algorithm significantly decreased the number of manually validated test results and can be used as a model for introducing autovalidation in other laboratory settings.

14 June 2020 in Biochemia Medica
Verified
Journal Article
Open access
PDF file
VRVladimira Rimac
Vladimira Rimac
AJAnja Jokic
Anja Jokic
SPSonja Podolar
Sonja Podolar
JTJelena Vlasic Tanaskovic
Jelena Vlasic Tanaskovic
LHLorena Honovic
Lorena Honovic
JKJasna Lenicek Krleza
Jasna Lenicek Krleza
Introduction: Autovalidation (AV) is an algorithm based on predefined rules designed, among others, to automate and standardize the postanalytical phase of laboratory work. The aim of this study was to examine the overall opinion of Croatian medical biochemistry laboratories regarding various aspects of AV. Material and methods: This retrospective study is an analysis of the responses of a survey about AV comprised of 18 questions, as part of Module 10 (“Postanalytical phase of laboratory testing”) of national External Quality Assessment program, administered by the Croatian Centre for Quality Assessment in Laboratory Medicine. Results were reported as percentages of total number of participants in survey or as proportions of observed data if the overall number of data was <100. Results: 121 laboratories responded to the survey, of which 76% do not use AV, while 11% of laboratories use AV in routine laboratory work. 16/29 laboratories implemented semi-automated AV for general biochemistry (7/29), haematology (5/29), and coagulation (4/29) tests. Analytical measurement ranges, critical values, flags from analysers, interference indices and delta check were the most commonly used rules in the algorithm. 12/29 laboratories performed validation of AV with less than 500 samples (8/29). 7/13 laboratories report the percentage of AV being 20-50%, while 10/13 answered that introduction of AV significantly reduced turnaround time (TAT) (for 20 - 25%), especially for biochemistry tests. Conclusions: Despite of its numerous benefits (i.e. shorter TAT, less manual validation, standardization of the postanalytical phase), only a small number of Croatian laboratories use AV.

15 September 2020 in International Journal of Laboratory Hematology
Verified
Journal Article
Closed access
PDF file
VRVladimira Rimac
Vladimira Rimac
IBInes Bojanić
Ines Bojanić
KGKoraljka Gojčeta
Koraljka Gojčeta
BĆBranka Golubić Ćepulić
Branka Golubić Ćepulić

13 April 2022 in International Journal of Laboratory Hematology
Verified
Journal Article
Closed access
VRVladimira Rimac
Vladimira Rimac
IBInes Bojanić
Ines Bojanić

15 February 2025 in Biomedicines
Verified
Journal Article
Open access
PDF file
NZNikolino Zura
Nikolino Zura
SVSilvijo Vince
Silvijo Vince
PPPorin Perić
Porin Perić
MVMarinko Vilić
Marinko Vilić
KMKrešimir Malarić
Krešimir Malarić
IŽIvona Žura Žaja
Ivona Žura Žaja
Background/Objectives: This study assessed the effects of 5G radiofrequency electromagnetic radiation (RF-EMR) at different frequencies (700 MHz, 2500 MHz, 3500 MHz) on the complete blood count (CBC), erythrocyte morphometry, and platelet activation after the short-term in vitro exposure of human blood. Methods: Blood samples from 30 healthy volunteers (15 men and 15 women, aged 25–40 years old) were collected at three intervals (14 days apart). For each collection, four tubes of blood were drawn per volunteer—two experimental and two controls. Experimental samples were exposed to 5G RF-EMR for 2 h at room temperature using a half-cone gigahertz transverse electromagnetic cell. The CBC was analysed via a haematology analyser, the erythrocyte morphometry was analysed using the SFORM program, and platelet activation was analysed via flow cytometry. Results: The CBC and platelet activation showed no significant differences between the experimental and control samples. However, the erythrocyte morphometry exhibited notable changes. At 700 MHz, the erythrocyte size, contour, and membrane roughness increased significantly for both sexes, with women’s cells showing greater sensitivity. At 2500 MHz, women exhibited an increased contour index and a decreased solidity and form factor. At 3500 MHz, women showed an increased contour index and outline but a decreased solidity, elongation, and form factor. Cluster analysis identified two erythrocyte subpopulations: smaller, rounder cells with smooth membranes and larger cells with rougher membranes. Conclusions: These results indicate that 5G RF-EMR exposure significantly alters erythrocyte morphometry. The strongest effects were observed at 700 MHz, where men exhibited greater membrane roughness, and women showed larger and rounder erythrocytes. These findings suggest that short-term in vitro 5G RF-EMR exposure disrupts the cytoskeleton, increasing membrane permeability and deformability.

15 February 2022 in Biochemia Medica
Verified
Journal Article
Open access
PDF file
AJAnja Jokic
Anja Jokic
JTJelena Vlasic Tanaskovic
Jelena Vlasic Tanaskovic
LHLorena Honovic
Lorena Honovic
JKJasna Lenicek Krleza
Jasna Lenicek Krleza
SPSonja Podolar
Sonja Podolar
VRVladimira Rimac
Vladimira Rimac
Interpretation of laboratory test results is a complex post-analytical activity that requires not only understanding of the clinical significance of laboratory results but also the analytical phase of laboratory work. The aims of this study were to determine: 1) the general opinion of Croatian medical biochemistry laboratories (MBLs) about the importance of interpretative comments on laboratory test reports, and 2) to find out whether harmonization of interpretative comments is needed. This retrospective study was designed as a survey by the Working Group for Post-analytics as part of national External Quality Assessment (EQA) program. All 195 MBLs participating in the national EQA scheme, were invited to participate in the survey. Results are reported as percentages of the total number of survey participants. Out of 195 MBLs, 162 participated in the survey (83%). Among them 59% MBLs implemented test result comments in routine according to national recommendations. The majority of laboratories (92%) state that interpretative comments added value to the laboratory reports, and a substantial part (72%) does not have feedback from physicians on their significance. Although physicians and patients ask for expert opinion, participants stated that the lack of interest of physicians (64%) as well as the inability to access patient’s medical record (62%) affects the quality of expert opinion. Although most participants state that they use interpretative comments and provide expert opinions regarding test results, results of the present study indicate that harmonization for interpretative comments is needed.