Shiguang Wang

Dr. Shiguang Wang

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 August 2012 in Physical Review A
Verified
Journal Article
Closed access
PDF file
JZJianwei Zhang
Jianwei Zhang
ZWZ. B. Wang
Z. B. Wang
SWShiguang Wang
Shiguang Wang
KMK. Miao
K. Miao
BWB. Wang
B. Wang
LWL. J. Wang
L. J. Wang
The ground-state hyperfine splittings of laser-cooled 113Cd+ and 111Cd+ ions confined in a linear Paul trap have been measured to be 15199862854.96(0.12) Hz and 14530507349.9(1.1) Hz, respectively, using a microwave-optical double-resonance technique. The results for 113Cd+ agrees with previous measurements very well, and the precision of the 111Cd+ is improved by 7 orders of magnitude compared to the best results reported in the literature. The possibility of a microwave frequency standard based on laser-cooled cadmium ions is also discussed.

14 May 2013 in Optics Express
Verified
Journal Article
Closed access
PDF file
SWShiguang Wang
Shiguang Wang
JZJianwei Zhang
Jianwei Zhang
KMK. Miao
K. Miao
ZWZ.B. Wang
Z.B. Wang
LWLijun Wang
Lijun Wang
We have developed a microwave frequency standard based on the 15.2 GHz ground-stated hyperfine transition of (113)C(+) ions. Using a laser-cooled ion cloud trapped in a linear quadrupole Paul trap, the clock transition frequency is measured to be 15 199 862 855.0125(87) Hz, with an accuracy at the 10(-13) level. The main errors are from the microwave frequency reference used in the experiment. The precision is improved by nearly two orders of magnitude than that reported before.

20 October 2013 in Applied Physics B
Verified
Journal Article
Closed access
PDF file
JZJ. W. Zhang
J. W. Zhang
SWShiguang Wang
Shiguang Wang
KMK. Miao
K. Miao
ZWZ. B. Wang
Z. B. Wang
LWLijun Wang
Lijun Wang

30 June 2016 in Scientific Reports
Verified
Journal Article
Open access
PDF file
CXC. Xu
C. Xu
SWShiguang Wang
Shiguang Wang
YFY. Y. Feng
Y. Y. Feng
LZL. Zhao
L. Zhao
LWLijun Wang
Lijun Wang
Quantum measurement using coherent superposition of intrinsic atomic states has the advantage of being absolute measurement and can form metrological standards. One example is the absolute measurement of magnetic field by monitoring the Larmor precession of atomic spins whilst another being the Ramsey type atomic clock. Yet, in almost all coherent quantum measurement, the precision is limited by the coherence time beyond which, the uncertainty decreases only as τ−1/2. Here we show that by non-destructively measuring the phase of the Larmor precession and regenerating the coherence via optical pumping, the self-sustaining Larmor precession signal can persist indefinitely. Consequently, the precision of the magnetometer increases with time following a much faster τ−1 rule. A mean sensitivity of 240 "Equation missing"<!-- image only, no MathML or LaTex --> from 1 Hz to 10 Hz is realized, being close to the shot noise level. This method of coherence regeneration may also find important applications in improving the performance of atomic clocks.

1 July 2019 in Journal of Magnetism and Magnetic Materials
Verified
Journal Article
Closed access
QZQ. Zhao
Q. Zhao
BFB.L. Fan
B.L. Fan
SWShiguang Wang
Shiguang Wang
LWL.J. Wang
L.J. Wang

5 July 2014 in Science China Physics, Mechanics & Astronomy
Verified
Journal Article
Closed access
PDF file
ZWZhengBo Wang
ZhengBo Wang
LZLu Zhao
Lu Zhao
SWShiguang Wang
Shiguang Wang
JZJianWei Zhang
JianWei Zhang
BWBo Wang
Bo Wang
LWLijun Wang
Lijun Wang