Scanning transmission X-ray microscopy (STXM) is a direct imaging technique with nanoscale resolution. But its resolution is limited by the spot size on the sample, i.e., by the manufacturing technique of the focusing element. As an emerging high-resolution X-ray imaging technique, ptychography utilizes highly redundant data from overlapping scans as well as phase retrieval algorithms to simultaneously reconstruct a high-resolution sample image and a probe function. In this study, we designed an accurate reconstruction strategy to obtain the probe spot with the vibration effects being eliminated, and developed an image enhancement technique for STXM by combining the reconstructed probe with the deconvolution algorithm. This approach significantly improves the resolution of STXM imaging and can break the limitation of the focal spot on STXM resolution when the scanning step size is near or below the spot size, while the data processing time is much shorter than that of ptychography. Both simulations and experiments show that this approach can be applied to STXM data at different energies and different scan steps using the same focal spot retrieved via ptychography.
Dynamic behavior is prevalent in biological and condensed matter systems at the nano- and mesoscopic scales. Typically, we capture images as “snapshots” to demonstrate the evolution of a system, and coherent X-ray diffraction imaging (CDI), as a lensless imaging technique, provides a nanoscale resolution, allowing us to clearly observe these microscopic phenomena. This paper presents a new dynamic CDI method based on zone-plate optics aiming to overcome the limitations of existing techniques in imaging fast dynamic processes by integrating the spatio-temporal dual constraint with a probe constraint. In this method, the modulus-enforced probe constraint and the temporal correlation of the dynamic sample low-frequency information are exploited and combined with an empty static region constraint in the dynamic sample. Using this method, we achieved a temporal resolution of 20 Hz and a spatial resolution of 13.2 nm, which were verified by visualized experimental results. Further comparisons showed that the reconstructed images were consistent with the ptychography reconstruction results, confirming the accuracy and feasibility of the method. This work is expected to provide a new tool for materials science and mesoscopic life sciences, promoting a deeper understanding of complex dynamic processes.
X-ray ptychography is an ultrahigh resolution imaging technique widely used in synchrotron radiation facilities. Its imaging performance relies on the quality of the acquired signals. However, the X-ray detectors used often suffer from signal loss due to sensor gaps, beamstops, defective pixels, overexposure, or other factors, resulting in degraded image quality. To suppress and compensate for the effects of signal loss, we proposed the known probe approach to partially recover the lost signals and introduced the high probe divergence strategy by investigating the effects of probe divergence on reconstruction quality under signal loss conditions. Both simulation and experiment results show that high probe divergence can effectively suppress the impact of signal loss on reconstruction quality while using a known probe as the initial probe for reconstruction can largely recover missing signals in Fourier space, resulting in a much better image than using a guessed initial probe. These strategies allow for high-quality imaging in the presence of signal loss without secondary data acquisition, significantly improving experimental efficiency and reducing radiation damage compared to previous strategies.