Kiril Simitchiev

Prof. Dr. Kiril Simitchiev

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 February 2008 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
KSKiril Simitchiev
Kiril Simitchiev
VSVioleta Milenkova Stefanova
Violeta Milenkova Stefanova
VKVeselin Kmetov
Veselin Kmetov
GAGeorge Andreev
George Andreev
NKNikolay Kovachev
Nikolay Kovachev
Antonio CanalsAntonio Canals
Antonio Canals
New approaches for acceleration of cloud point extraction of Rh, Pd and Pt by microwave and ultrasound irradiation have been investigated. 2-Mercaptobenzothiazole and Triton X-100 were used as ligand and non-ionic surfactant, respectively. Microwave irradiation substantially increased the procedure efficiency. In contrast no significant effect was observed when a micellar solution was treated with ultrasound energy. The acceleration of complex formation reactions by reducing agents (KI and SnCl2) has also been studied. The use of SnCl2 was a prerequisite for quantitative extraction of Rh. Since the extraction kinetics of platinum depends on its oxidation state and presence of Pd, the addition of SnCl2 equalized the platinum extraction behavior. For the first time the whole cloud point procedure was successively accomplished in a microwave system. 10 min of irradiation were sufficient for gravimetrical phase separation and quantitative extraction of platinum group metals. As a result the procedure time was shortened by a factor of 9 in comparison to conventional hot plate cloud point extraction. The surfactant-rich phase was analyzed after dilution with 1 M HCl by continuous nebulization to ICP-MS. Quantitative recoveries and good plasma tolerance were reported. Detection limits of 1 ng.l−1 (Rh), 5 ng.l−1 (Pd), and 6 ng.l−1 (Pt) were achieved regarding a preconcentration factor of 8. The microwave-assisted cloud point extraction has been successfully applied for simultaneous determination of trace amounts of platinum group metals in pharmaceutical products (Tritace, Vivace, Laprilen and Enalapril).

27 September 2024 in Talanta
Verified
Journal Article
Open access
Asya Dimitrova HristozovaAsya Dimitrova Hristozova
Asya Dimitrova Hristozova
Lorena VidalLorena Vidal
Lorena Vidal
MAMiguel Ángel Aguirre
Miguel Ángel Aguirre
KSKiril Simitchiev
Kiril Simitchiev
ACAntonio Canals
Antonio Canals
The current research aims to develop a new analytical method applying a dispersive liquid-liquid microextraction (DLLME) assisted by vortex and using an environmentally friendly extractant for the preconcentration of organochlorine and organophosphorus pesticides followed by gas chromatography-tandem mass spectrometry (GC-MS/MS) analysis. The extractant (i.e., natural deep eutectic solvent (NADES)) is safe, cheap, biodegradable and can be prepared by simply mixing DL-menthol and decanoic acid (molar ratio 2:1). The main experimental factors affecting the extraction of all analytes evaluated (19 organochlorine and organophosphorus pesticides) have been optimised using a multivariate analysis consisting in two steps: a Plackett-Burman design followed by a central composite design (CCD). Seven experimental factors have been evaluated: (i) sample volume; (ii) NADES volume; (iii) sample pH; (iv) extraction time; (v) centrifugation time; (vi) centrifugation speed; and (vii) ionic strength (NaCl %, w v-1). For the significant variables, the optimum values were 10 mL sample and 45 μL NADES. No pH adjustment as well as addition of NaCl were needed. The other variables were set at 3 min extraction time, 5 min centrifugation time and 900×g centrifugation speed, respectively. Under the optimised extraction conditions, the limit of quantification (LOQ) values ranged between 0.2 and 78 ng L-1 for all analysed pesticides. Furthermore, the proposed analytical method has been successfully applied to drinking water (bottled spring water). The recovery study (n = 3) has been evaluated at 0.1, 1.0 and 5.0 μg L-1 spiking levels, obtaining relative recovery values within the range of 70 % and 117 % and RSD values between 1 % and 20 % for all the analytes studied, except for p,p-DDT (56-77 % in high conductivity water samples).

1 December 2017 in Journal of Molecular Liquids
Verified
Journal Article
Closed access
TSTeodora Stefanova-Bahchevanska
Teodora Stefanova-Bahchevanska
Nikolina Petkova MilchevaNikolina Petkova Milcheva
Nikolina Petkova Milcheva
SZSerhii Zaruba
Serhii Zaruba
VAVasil Andruch
Vasil Andruch
VDVassil Delchev
Vassil Delchev
Kiril Blazhev GavazovKiril Blazhev Gavazov
Kiril Blazhev Gavazov


22 November 2023 in Talanta
Verified
Journal Article
Open access
Asya Dimitrova HristozovaAsya Dimitrova Hristozova
Asya Dimitrova Hristozova
KSKiril Simitchiev
Kiril Simitchiev
VKVeselin J. Kmetov
Veselin J. Kmetov
ERErwin Rosenberg
Erwin Rosenberg
Cloud point extraction is an environmentally benign and simple separation/concentration procedure that can be regarded as an alternative to classical liquid-liquid extraction. In the current work, it was studied the compatibility of cloud point extraction followed by back-extraction in low volume of organic solvent with gas chromatography-mass spectrometry (GC-MS and GC-MS/MS). Triton X-100 was preferred than Triton X-114 as a surfactant to produce the clouding phenomenon and hexane or isooctane was found to be appropriate organic solvents which can be used at the back-extraction step. It was observed that ca. 0.09 % w/w Triton X-100 was co-extracted in the organic phase (hexane or isooctane) so further study was carried out to find out its effect on the GC-MS (GC-MS/MS) measurement when liquid samples are injected without any pre-cleaning to remove the surfactant. The chromatographic separation and the mass detection were not deteriorated by the concomitant Triton X-100 for analysis of several Organochlorine and Organophosphorus pesticides (alpha-HCH, beta-HCH, gamma-HCH, Pentachlorobenzene, Hexachlorobenzene, Chlorpyrifos, Chlorpyrifos-methyl, Aldrin, Endrin, Dieldrin, alpha-Endosulfan, Heptachlor, Heptachlor-endo-epoxide-A, o,p-DDD, p,p-DDD, o,p-DDE, p,p-DDE, o,p-DDT and p,p-DDT). The stability of the GC system when introducing surfactant was assessed as acceptable (typically the peak area RSD% for 20 consecutive injections were below 5 %). Under the developed vaporization conditions using PTV or PSS injectors it can be deduced that Triton X-100 is deposited on the inner surface of the liner. This effect is beneficial since the resulting surfactant layer makes a surface which facilitates the pesticides transfer to the GC column. As a consequence, for some analytes, a substantial enhancement (up to 2.3 times) in the sensitivity was observed when the matrix-matched medium (0.09 % w/w Triton X-100 in organic solvent) is used compared to calibration in solely hexane or isooctane. Meanwhile, the measurement precision in the presence of Triton X-100 remains unchanged. The GC-MS/MS analysis was alternatively accomplished by the use of glass or metal liner and it was found that the glass one should be preferable. Finally, it can be concluded that cloud point extraction with Triton X-100 can be combined with GC-MS or GC-MS/MS analysis by applying liquid injection of the target analytes transferred in organic solvents such as hexane or isooctane. We have established a positive effect of Triton X-100 on the instrumental performance which is on opposite to the generally accepted concern of the negative influence of the surfactants on the gas chromatographic analysis.

1 January 2018 in Neoplasma
Verified
Journal Article
Closed access
YFYana Feodorova
Yana Feodorova
DTD. Tashkova
D. Tashkova
IKI. Koev
I. Koev
ATA. Todorov
A. Todorov
GKG. Kostov
G. Kostov
VSV. Sarafian
V. Sarafian
Novel insights into transcriptional dysregulation in colorectal cancer