Adam Golcs

Adam Golcs


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 May 2018 in Sensors
Verified
Journal Article
Open access
PDF file
AGAdam Golcs
Adam Golcs
VHViola Horvath
Viola Horvath
Peter HuszthyPeter Huszthy
Peter Huszthy
TTTünde Tóth
Tünde Tóth
Lead is a particularly toxic heavy metal that is present above acceptable levels in the water of many countries. This article describes a quick detection method of lead(II) ions using a polyvinyl chloride (PVC)-based ion-selective membrane electrode containing an acridono-crown ether ionophore by potentiometry. The electrochemical cell exhibits a Nernstian response for lead(II) ions between the concentration range of 10−4 to 10−2 M, and can be used in the pH range of 4–7. The applicability of this sensor was verified by measuring a multicomponent aqueous sample. Under the given conditions, this electrode is suitable for the selective quantitative analysis of lead(II) ions in the presence of many additional metal ions.

8 June 2021 in Journal of Inclusion Phenomena and Macrocyclic Chemistry
Verified
Journal Article
Open access
PDF file
AGAdam Golcs
Adam Golcs
PVPanna Vezse
Panna Vezse
BÁBálint Árpád Ádám
Bálint Árpád Ádám
PHPéter Huszthy
Péter Huszthy
TTTünde Tóth
Tünde Tóth
Crown ethers containing an acridone or an acridine unit are successfully applied opto- and electrochemical cation sensors. The heteroaromatic unit of these macrocycles can be in different forms during the applications, which have a strong influence on the sensing behavior. Moreover, in the case of acridono-macrocycles a prototropic equilibrium takes place upon complexation, which is effected by the physicochemical characteristics. A Pb2+-selective acridono-18-crown-6 ether and its 9-phenylacridino-analogue were used as model compounds for comparing the different forms of the heterocyclic units of these sensor molecules. Since in most practical sensor applications of the fluorescent hosts a non-neutral aqueous medium is present, studies on complexation and signaling were carried out from the aspect of the relationship among protonation, coordinating ability, complex stability and tautomeric equilibrium. A strong interdependence among these factors was found and limitations of using unsubstituted acridino- and acridono-sensor molecules in comparison with their 9-substituted-acridino-analogues were discussed. This study will hopefully serve as a useful standpoint for future development of ionophore-based sensors containing an acridone or an acridine unit.

31 May 2020 in Molecules
Verified
Journal Article
Open access
PDF file
AGAdam Golcs
Adam Golcs
BÁBálint Árpád Ádám
Bálint Árpád Ádám
VHViola Horvath
Viola Horvath
TTTünde Tóth
Tünde Tóth
Peter HuszthyPeter Huszthy
Peter Huszthy
New highly lipophilic enantiopure crown ethers containing a heterocyclic unit have been synthesized. Phase transport, UV-Vis- and fluorescence spectrophotometric investigations as well as electrochemical studies on the complexation of the new macrocycles with several amine and amino acid derivatives were also carried out. Achiral amines were used for studying the structural preference of the new macrocycles. Among the studied structural features of the guest molecules, the intermolecular π-π interaction showed the most significant effect on complexation, which made the aralkylamine-type compounds the most preferable guest molecules. The studied liquid membrane-based applications and photophysical investigations showed appreciable enantiomeric recognition toward some aralkylamine model compounds with homochiral preferences. New crown ether derivatives (R,R)-2 and (S,S)-2 were successfully applied as enantioselective carrier and sensor molecules.

29 April 2022 in Molecules
Verified
Journal Article
Open access
PDF file
PVPanna Vezse
Panna Vezse
BBBianka Benda
Bianka Benda
AFAndrás Fekete
András Fekete
AGAdam Golcs
Adam Golcs
TTTünde Tóth
Tünde Tóth
Peter HuszthyPeter Huszthy
Peter Huszthy
A great number of biologically active compounds contain at least one amine function. Appropriate selectivity can only be accomplished in a few cases upon the substitution of these groups, thus functionalization of amines generally results in a mixture of them. The separation of these derivatives with very similar characteristics can only be performed on a preparative scale or by applying pre-optimized HPLC methods. A tris(pyridino)-crown ether was designed and synthetized for overcoming these limitations at a molecular level. It is demonstrated, that this selector molecule is able to distinguish protonated primary, secondary and tertiary amines by the formation of reversible complexes with different stabilities. This degree of substitution-specific molecular recognition of amines opens the door to develop separation processes primarily focusing on the purification of biologically active compounds in a nanomolar scale.

1 July 2021 in Analytica Chimica Acta
Verified
Journal Article
Open access
AGAdam Golcs
Adam Golcs
GDGergő Dargó
Gergő Dargó
György Tibor BaloghGyörgy Tibor Balogh
György Tibor Balogh
PHPéter Huszthy
Péter Huszthy
TTTünde Tóth
Tünde Tóth
Although many Pb2+-selective optodes have been developed so far, methods using optical sensor membranes have not become widespread in environmental analytical practice. In order to create a bulk optode sensor, which can overcome all of the main drawbacks in the application of conventional optode membranes, - i.e., pH-dependence, long response time and the leakage of the ionic components - unusually thick PVC membrane was developed, embedded in microtiter plates and operated on a novel concept. This is the first reported work, which applies a plate-format optode as well as a direct optode-type sensing membrane for determination of Pb2+. We reported here also the first example for the application of an ionic component-free bulk optode membrane to avoid the membrane leakage, improve the regenerability and extend the lifetime of the membrane. The reported sensor has a LOD above 4.0 × 10-7 M (∼83 μg L-1), thus it is unsuitable for the effective monitoring of drinking waters, but considered to be a promising method for monitoring contamination episodes. On the other hand, the widest pH-independent working range of 4.3 < pH < 7.0 among bulk optodes reported in the literature was realized and an unprecedentedly fast response time of <10 s was achieved. The effectiveness of the applied method was investigated by measuring Pb2+-spiked multicomponent aqueous solutions as simulated environmental or wastewater samples containing near equimolar amounts of Ag+, Ca2+, Co2+, Cu2+, K+, Mg2+, Na+ and Zn2+ as acetate salts. In the presence of these potential competing ions with a concentration not greater than the typical ionic strength of surface freshwaters (∼10-3 M) the reported sensor proved to be appropriate for the selective detection of Pb2+ without any preparation of the samples (e.g., preconcentration, buffering, addition of excipients, etc.) with a required sample volume of only 100 μL. An outstanding analytical performance could be achieved within an average time of less, than 5 s/sample. The reported fluorescent probe is considered to be a promising method for replacing atomic absorption spectroscopy- (AAS), anodic stripping voltammetry- (ASV) or inductively coupled plasma- (ICP) based techniques as well as conventional ion-selective bulk membranes in high-throughput preliminary environmental monitoring of Pb2+, as it provides a cheap and unprecedentedly fast qualitative analysis of contaminated surface and wastewaters.

1 July 2021 in Molecules
Verified
Journal Article
Open access
PDF file
AGAdam Golcs
Adam Golcs
KKKorinna Kovács
Korinna Kovács
PVPanna Vezse
Panna Vezse
TTTünde Tóth
Tünde Tóth
Peter HuszthyPeter Huszthy
Peter Huszthy
Acridino-diaza-20-crown-6 ether derivatives as new turn-on type fluorescent chemosensors with an excellent functionality and photophysical properties have been designed and synthesized for metal ion-selective optochemical sensing applications. Spectroscopic studies revealed that in an acetonitrile-based semi-aqueous medium, the sensor molecules exhibited a remarkable fluorescence enhancement with high sensitivity only toward Zn2+, Al3+ and Bi3+, among 23 different metal ions. Studies on complexation showed a great coordinating ability of logK > 4.7 with a 1:1 complex stoichiometry in each case. The detection limits were found to be from 59 nM to micromoles. The new ionophores enabled an optical response without being affected either by the pH in the range of 5.5–7.5, or the presence of various anions or competing metal ions. Varying the N-substituents of the new host-backbone provides diverse opportunities in both immobilization and practical applications without influencing the molecular recognition abilities.