Objective: The purpose of this study was to assess the speech recognition in noise when using a transparent mask that allows greater visibility of the talker’s face compared to an opaque mask in persons with normal and impaired hearing via an online format. Design: A repeated-measures design was used to evaluate the auditory-visual recognition of sentences recorded in background noise with transparent and opaque face masks, and without a mask (N = 154). In a smaller follow-up study (N = 29), the same files were presented via auditory-only presentation to determine if differences observed in the transparent and opaque mask conditions were attributable to additional visual cues or to acoustic differences between the recordings of the two mask types. Listeners completed the 40-minute online session on a computer, laptop, or tablet in a quiet room via their personal listening devices (earbuds or hearing assistive device). The adult volunteers who used English as their first language were recruited through social media links and email and categorized into three groups: normal hearing and confirmed or suspected hearing loss either with or without the use of assistive listening devices. Results: Auditory-visual recognition of sentences recorded with the transparent mask was significantly better (M = 68.9%) than for sentences recorded with the opaque mask (M = 58.9%) for all participants. There was a trend for those who used hearing assistive technology to score lower than the other two groups who had similar performance across all conditions regardless of the mask type. Subjective ratings of confidence and concentration followed the expected pattern based on objective scores. Results of the auditory-only presentation of the sentences to listeners with normal hearing suggested that the transparent mask benefits were not attributable to an acoustic advantage but rather to the addition of the visual cues of the talker’s face available through the transparent mask. In fact, performance in the auditory-only presentation was significantly lower with the transparent mask (M = 40.7%) compared to the opaque mask (M = 58.2%). Conclusions: Use of transparent masks can significantly facilitate speech recognition in noise even for persons with normal hearing and thus may reduce stressful communication challenges experienced in medical, employment, and educational settings during the global pandemic. To mitigate the spread of COVID-19 and facilitate communication, safety-approved transparent masks are strongly encouraged over opaque masks.
Purpose: The purpose of this study was to compare the benefits of 3 types of remote microphone hearing assistance technology (HAT), adaptive digital broadband, adaptive frequency modulation (FM), and fixed FM, through objective and subjective measures of speech recognition in clinical and real-world settings. Method: Participants included 11 adults, ages 16 to 78 years, with primarily moderate-to-severe bilateral hearing impairment (HI), who wore binaural behind-the-ear hearing aids; and 15 adults, ages 18 to 30 years, with normal hearing. Sentence recognition in quiet and in noise and subjective ratings were obtained in 3 conditions of wireless signal processing. Results: Performance by the listeners with HI when using the adaptive digital technology was significantly better than that obtained with the FM technology, with the greatest benefits at the highest noise levels. The majority of listeners also preferred the digital technology when listening in a real-world noisy environment. The wireless technology allowed persons with HI to surpass persons with normal hearing in speech recognition in noise, with the greatest benefit occurring with adaptive digital technology. Conclusion: The use of adaptive digital technology combined with speechreading cues would allow persons with HI to engage in communication in environments that would have otherwise not been possible with traditional wireless technology.
Purpose: To compare the benefits of adaptive FM and fixed FM systems through measurement of speech recognition in noise with adults and students in clinical and real-world settings. Method: Five adults and 5 students with moderate-to-severe hearing loss completed objective and subjective speech recognition in noise measures with the 2 types of FM processing. Sentence recognition was evaluated in a classroom for 5 competing noise levels ranging from 54 to 80 dBA while the FM microphone was positioned 6 in. from the signal loudspeaker to receive input at 84 dB SPL. The subjective measures included 2 classroom activities and 6 auditory lessons in a noisy, public aquarium. Results: On the objective measures, adaptive FM processing resulted in significantly better speech recognition in noise than fixed FM processing for 68- and 73-dBA noise levels. On the subjective measures, all individuals preferred adaptive over fixed processing for half of the activities. Adaptive processing was also preferred by most (8–9) individuals for the remaining 4 activities. Conclusion: The adaptive FM processing resulted in significant improvements at the higher noise levels and was preferred by the majority of participants in most of the conditions.
3 August 2020 in Journal of the American Academy of Audiology
Background Although hearing aids (HAs) and cochlear implants (CIs) can provide significant benefits to persons with hearing loss, users frequently report difficulty hearing in noisy environments, particularly when there are multiple talkers. Little is known about the benefits provided by currently available wireless microphones in multitalker situations. Purpose The purpose of this study was to compare the benefits received in speech recognition in noise by adults with hearing loss when using two different wireless microphone types in a simulated group setting. Research Design A quasi-experimental, repeated-measures design was used where performance in a control condition, HA/CI alone, was compared with performance in two wireless microphone intervention conditions. Study Sample Participants included ten listeners, aged 20-92 years, with bilateral sensorineural hearing loss who were experienced HA or CI users. Intervention The two wireless microphones by Phonak, Roger Pen, and Roger Select used the same digital modulation protocol to transmit the signal to compatible receivers. However, the Roger Pen operated in a fixed omnidirectional mode, whereas the Roger Select operated in an adaptive directional mode. Data Collection and Analysis Participants were asked to repeat Hearing in Noise Test sentences presented in restaurant noise in three conditions: HA/CI alone, HA/CI with a Roger Pen, or HA/CI with a Roger Select microphone placed in the center of a round table. Sentences were presented from one of five loudspeakers equally spaced with the participant, while restaurant noise was presented on each side at four signal-to-noise ratios (SNRs), including +5, 0, −5, and −10 dB. A two-way, repeated-measures analysis of variance was performed with main effects of listening condition and noise level. Results Significantly greater speech recognition performance was achieved with the wireless microphones than with listening with just the HA or CI. Furthermore, at the −5- and −10-dB SNR conditions, the Roger Select resulted in significantly better performance than the Roger Pen microphone. Conclusions The results suggest that the Roger Select microphone can provide significant benefits in speech recognition in noise over the use of HA/CI alone (61%) and also significant benefits over the use of a Roger Pen (16%) in a simulated group dining experience.
Background: Identifying and treating hearing loss can help improve communication skills, which often leads to improved quality of life. Many people do not seek medical treatment and, therefore, go undiagnosed for an extended period before realizing they have hearing loss. This study presents a self-administered, low-cost, smartphone-based hearing test application (HearTest) to quantify the pure-tone hearing thresholds of a user. The HearTest application can be used with commercially available smartphone devices and an earphone with the mentioned specification. Methods: Air-conduction-based pure-tone audiometry for the smartphone application was designed and implemented to detect hearing thresholds using a traditional “10 dB down and 5 dB up” approach. Employed smartphone-earphone combination was calibrated with respect to a GSI-61 audiometer and insert earphone ER-3A to maintain clinical standards with the help of subjective testing on 20 normal-hearing (NH) participants. Results: Further subjective testing on 14 participants with NH and retesting on five participants showed that HearTest achieves high-accuracy audiogram within clinically acceptable limits (≤10 dB HL mean difference) when compared with the reference clinical audiometer. Hardware challenges and limitations in air-conduction-based hearing tests through smartphones and ways to improve their accuracy and reliability are discussed. Conclusion: The proposed smartphone application provides a simple, affordable, and reliable means for people to learn more about their hearing health without needing access to a formal clinical facility.
Hearing aids are often not sufficient for optimal communication between a listener and a talker. Therefore, numerous options for wireless connectivity between the listener and the talker designed to improve communication have become widely available. From the original wireless option of the induction loop system, most of the current solutions involve a digital signal with high quality and limited interference. Many are proprietary and only operate with a given manufacturer's devices, while others are more universal as long as the digital receiver can be connected to the listener's personal device. In addition, connectivity options to assist those with hearing loss are now readily available on the smartphone which can be used as a remote microphone. Therefore, it is paramount that the available wireless protocols be considered relative to the listener's experience with wireless technology so that solutions may be offered that are efficient, economical, and effective.