Due to the long-term coupling effect of a train load and groundwater, the surrounding rock at the tunnel bottom will soften in a certain range and the mechanical parameters of the surrounding rock will decrease, causing the uneven distribution of the confining pressure at the tunnel bottom and affecting the base concrete structure service life. In this research, the method of combining field tests and numerical simulation is adopted, and the vertical displacement, vertical acceleration, and maximum and minimum principal stresses are used as evaluation indicators. The dynamic response law of the base structure with the softened surrounding rock of the heavy-duty train is analyzed, and the Miner linear cumulative damage theory is introduced to obtain the service life of the tunnel bottom structure under different softening conditions. The results show that with the decrease in the softening coefficient and the increase in the softening thickness of the bedrock, the displacement, acceleration, and principal stress response indexes of the structure increase by varying degrees, and the service life of the base structure decreases almost linearly. The maximum vertical displacement, acceleration, and tensile stress are located directly below the track, and the maximum compressive stress is located at the connection between the inverted arch and the side wall. According to the predicted value of the service life, the reliability of the base structure is divided into four levels: safety, warning, danger, and serious danger.
This paper discusses research on the dynamic response characteristics of a heavy-haul railway tunnel and the surrounding soil under the conditions of substrate health and a base void. The detection results of the base condition of 20 double-track tunnels for a heavy-haul railway show the main distribution law of base voids. Based on this, a 1:20 scale test model of a heavy-haul railway tunnel is established. The vibration load of the train is established by a vibration exciter arranged at the tunnel invert. The dynamic response and attenuation law of a heavy-haul railway tunnel lining structure and the surrounding soil are tested using acceleration sensors, strain gauges, and soil pressure boxes. The research results show that most of the diseases are concentrated below the heavy-haul line. The base void causes the peak acceleration of the nearby tunnel invert to increase by 55.6%. Tunnel annular construction joints reduce the conductivity of the vibration waves in the axial direction of the tunnel. The acceleration attenuation rate of the soil above the tunnel invert is significantly less than that under the invert. The base void reduces the acceleration of the nearby soil layer by 19.4% and increases the stress on the surface of the nearby tunnel invert by 21.3%, and the stress change amplitude increases by 0.55%. The tunnel structure in the area of the base void experiences fatigue damage. The base void causes the compaction and bearing capacity of the nearby soil to decrease and the softening speed of the tunnel basement soil layer to increase. Therefore, for the basement damage to heavy-haul railway tunnels, “early detection, early treatment” should be performed.
12 August 2025 in Tunnelling and Underground Space Technology
This study investigates the dynamic response characteristics of the tunnel bottom structure, focusing on a heavy-haul railway tunnel. To assess the condition of the tunnel bottom, geological radar and drilling core techniques were employed, along with on-site dynamic testing. The dynamic stress and acceleration response characteristics of the tunnel bottom structure, situated in grade V surrounding rock, were analyzed under axle loads of 25 t, 27 t, and 30 t. Both time-domain and frequency-domain analyses were conducted to explore the impact of structural defects on the dynamic response of the tunnel bottom. The results indicate that the dynamic response of the tunnel bottom structure increases linearly with increasing train axle load. In the presence of void-related defects at the tunnel bottom, the dynamic response of the structure is amplified, with an observed growth rate of up to 26.3%. Furthermore, the load exerted by heavy-duty trains on the tunnel bottom structure is predominantly a low-frequency effect, concentrated within the range of 0–20 Hz. Analysis of the 1/3 octave band reveals that the maximum difference in acceleration levels occurs at a center frequency of 31.5 Hz. Additionally, as the distance between the measurement point and the vibration source increases, the dynamic response induced by the void defect on the tunnel bottom structure weakens.