Objectives: The objective of this study was to assess the tissue response and strength of traditional and unidirectional suture materials, depending on the conditions of use and the timing following implantation. Methods: Eighty male Wistar rats were randomly assigned to four groups depending on the suture used: unidirectional absorbable V-locTM 180 or non-absorbable V-locTM PBT and traditional absorbable MaxonTM or non-absorbable NovafilTM. Three and six weeks following the closure of the abdominal wall defect (AWD) and subcutaneous suture implantation at the withers according to group assignment, 10 animals from each group were euthanized for implanted sutures mechanical testing and histological examination. Results: The inflammatory reaction in the AWD closure area was maximal and significantly different from the subcutaneous implantation by week 3 for all groups. At six weeks, the tissue reaction did not depend on the place of implantation. However, four rats from the MaxonTM group demonstrated suture failure with diastasis formation. Non-absorbable barbed sutures exhibited an absence of suture failure and the maximum scar thickness. Both intact absorbable materials (V-LocTM 180 and MaxonTM) exhibited a significant breaking strength margin over the non-absorbable. By week 6, the preserved strength of the V-locTM 180 sutures at the AWD was 33% (15–58%), and under the skin—49.7% (48–59%) (p = 0.005). For MaxonTM, these values were 38% (35–48%) for the AWD and 44% (34–49%) for the subcutaneous implantation. Conclusions: Absorbable and non-absorbable suture materials, depending on the conditions and timing of implantation, cause various tissue reactions which could affect the wound healing and the number of postoperative complications.

3 October 2025 in Russian Journal of Evidence-Based Gastroenterology
Verified
Journal Article
Closed access
GIG.B. Ivakhov
G.B. Ivakhov
STS.M. Titkova
S.M. Titkova
MAMichael Anurov
Michael Anurov
KSKonstantin Shadin
Konstantin Shadin
AKAleksandra Kalinina
Aleksandra Kalinina
ASA.V. Sazhin
A.V. Sazhin
Objective. To evaluate the effect of different types of unidirectional barbed sutures on the mechanical properties of postoperative scars at various time points following closure of an experimental musculoaponeurotic defect. Material and methods. Forty male Wistar rats were randomly assigned to two groups according to the suture material used: absorbable V-Loc 180 and nonabsorbable V-Loc PBT. At 3 and 6 weeks after abdominal wall defect closure, 10 animals from each group were euthanized for mechanical testing of postoperative scars and histological examination. Results. At week 3, the highest tensile strength was observed in the V-Loc PBT group, significantly exceeding that in the V-Loc 180 group (0.87 ± 0.17 N/mm² vs. 0.64 ± 0.12 N/mm²; p=0.035). Between weeks 3 and 6, tensile strength remained unchanged in the V-Loc 180 group (p=0.68), whereas in the V-Loc PBT group it decreased (p=0.017) alongside an increase in extensibility (p=0.027). By week 6, scar thickness significantly increased in both groups, with no significant intergroup differences in mechanical parameters. At week 3, a pronounced tissue reaction around the sutures was noted, which markedly subsided by week 6, with the sutures surrounded by mature connective tissue. In two animals from the V-Loc 180 group (at weeks 3 and 6), impaired connective tissue formation was observed, characterized by mature chondrocyte appearance around the suture material. Conclusion. Long-lasting absorbable and nonabsorbable unidirectional barbed sutures elicit different early tissue responses after experimental musculoaponeurotic defect closure, influencing wound healing and the mechanical strength of postoperative scars.