André Luís de Oliveira Cavaignac

Dr. André Luís de Oliveira Cavaignac

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in International Journal of Advanced Engineering Research and Science
Verified
Journal Article
Open access
PDF file
JUJhelison Gabriel Lima Uchoa
Jhelison Gabriel Lima Uchoa
MSMarcos Jean Araujo de Sousa
Marcos Jean Araujo de Sousa
LSLuan Henrique Varão Silva
Luan Henrique Varão Silva
ACAndré Luís de Oliveira Cavaignac
André Luís de Oliveira Cavaignac
Qualis indexed Engineering Journal and Science Journal to publish paper with DOI, NAAS Rating and journal has global recognized indexing

25 November 2018 in Brazilian Journal of Operations & Production Management
Verified
Journal Article
Open access
PDF file
ACAndré Luís de Oliveira Cavaignac
André Luís de Oliveira Cavaignac
JUJhelison Gabriel Lima Uchoa
Jhelison Gabriel Lima Uchoa
Highlights: 1- Severity, occurrence and detection indices were obtained for specific use in construction safety; 2- Important theoretical contribution to the use of FMEA in safety of construction work; 3- Obtaining the S, O and D indices better suited to civil construction will encourage the use of FMEA in the area; 4- A quick reference table of S, O and D indexes was proposed for use by occupational safety professionals; 5- The quick reference table will allow the RPNs of the fault modes to be safely compared between different situations and different applicators. Goal: The achievement of FMEA indices better adapted to the area of occupational safety in construction. From a quick reference table, the use of the FMEA will be facilitated by professionals in the area. Design / Methodology / Approach: For the elaboration of this work were carried out researches in the literature available in scientific journals on the subject. To obtain the severity tables, the conversion of concepts of maintenance and reliability to concepts of accident severity was performed. For the occurrence table the Ford Handbook model was used (FORD, 2011), and as the database of accident statistics the most up-to-date social security yearbook was used (FAZENDA, 2016). For the detection table, a detection index model was proposed that was discussed based on commonly used risk management procedures and tools. Results: Individual tables were obtained for each FMEA index. The indices were adapted to the reality of the application of FMEA in work safety in construction. From the individual tables, a quick reference table containing the three FMEA indices related to the qualitative scale of each was obtained. Limitations of the investigation: The study limits itself to adapting the FMEA indices for work safety in construction. This study may serve as a basis for future studies on obtaining the FMEA indexes for work safety applied in other areas of activities, requiring adequate scientific sources. Regarding the validation of the indices, it is noticeable the difficulty of comparing these indices proposed in this work with indices applied subjectively and without scientific reference, relying only on the skill and previous experience of the applicator. However, it is reasonable to say that the FMEAS applied with the indices obtained in this work will have a better accuracy in representing the reality, regardless of the applicator's ability. Practical implications: Reduce the difficulties in choosing the S, O and D indices for the application of FMEA in construction safety, reduce the inaccuracy in obtaining the risk priority number for failure modes and diffuse the use of FMEA for risk analysis and prevention occupations in construction are the main theoretical implications of this work. Originality / Value: there are studies in the literature on the application of FMEA in various areas - maintenance and product development, for example - but there is very little research on the application of FMEA in occupational safety. In addition, FMEA application studies cite the difficulty of choosing the S, O and D indices, but there is an absence of studies seeking solutions to this imprecision. In this sense, this work seeks to contribute to a choice of the FMEA indexes, which is easier and more efficient due to the better adaptation of the same to the occupational safety area in civil construction.

7 June 2018 in Crystals
Verified
Journal Article
Open access
PDF file
ACAndré Luís de Oliveira Cavaignac
André Luís de Oliveira Cavaignac
RSRilleands Alves Soares
Rilleands Alves Soares
RLRicardo Jorge Cruz Lima
Ricardo Jorge Cruz Lima
PFPedro De Freitas Façanha Filhoo
Pedro De Freitas Façanha Filhoo
PFPaulo de Tarso Cavalcante Freire
Paulo de Tarso Cavalcante Freire
Single-crystal samples of the semi-organic compounds mono-l-alaninium nitrate and monoglycine nitrate have been studied by Raman spectroscopy in a diamond-anvil cell up to 5.5 GPa, in order to observe the behavior of the deformation mode of NH3 units. It was observed for these semi-organic crystals that increasing pressure produces a decrease in the wavenumber of the band associated with the deformation vibration, differently from most of the modes. Comparatively, mono-l-alaninium has a higher dν/dP than monoglycine nitrate, for the band associated with the deformation vibration. The anomalous behavior is explained in terms of the effect of high pressure in the short and linear intermolecular hydrogen bonds.

9 October 2019 in Crystals
Verified
Journal Article
Open access
PDF file
ACAndré Luís de Oliveira Cavaignac
André Luís de Oliveira Cavaignac
RLRicardo Jorge Cruz Lima
Ricardo Jorge Cruz Lima
PFPaulo de Tarso Cavalcante Freire
Paulo de Tarso Cavalcante Freire
In this work we present the continuation of studies carried out on the changes of geometric parameters of the hydrogen bonds in amino acid crystals subjected to temperature or pressure variations. Changes in geometric parameters of the hydrogen bonds are correlated with the temperature behavior of the Raman wavenumber of NH3+ torsional band. Now four monocrystals, L-valine, L-isoleucine, taurine, and L-arginine hydrochloride monohydrate, are studied. Temperature evolution of the Raman wavenumber of NH3+ torsional band, with positive slope (dν/dT = 0.023 cm−1/K) of L-isoleucine, can be related to the stability of the crystal structure and the hydrogen bonds strengths on heating due to different temperature lattice parameters variation.

1 March 2020 in Brazilian Journal of Operations & Production Management
Verified
Journal Article
Open access
PDF file
ACAndré Luís de Oliveira Cavaignac
André Luís de Oliveira Cavaignac
JUJhelison Gabriel Lima Uchoa
Jhelison Gabriel Lima Uchoa
HSHeyglon Fábio Oliveira Dos Santos
Heyglon Fábio Oliveira Dos Santos
Goal: In this work, the application of FMEA (failure mode and effects analysis) in the execution of maintenance of water network in a medium size city in the state of Maranhao was approached. FMEA (failure mode and effects analysis) with occupational safety approach is applied in the execution of water supply network maintenance in a medium size city in the state of Maranhao. This work shows that FMEA is an effective tool for risk prioritization in work process. The FMEA application with use of index reference table can become faster than application without reference table - and thus spread the tool for risk analysis. Design / Methodology / Approach: A photographic records was carried out in loco and the main risks to the workers were enumerated and based on the obtained data, a risk analysis was elaborated with the application of FMEA (Failure modes and effects analysis). Results: The maintenance services teams of the supply system are subject to a high risk of accidents caused mainly by the working conditions precariousness. It was observed that the services of manual excavations and the lack of use of PPE (helmet, gloves, pants suitable for flooded environments and etc.) have high risk index (RPN) and that the mismanagement added to the unsafe behavior were the main factors to accident occurrence in this type of work. Limitations of the investigation: The study studied the reality found in a medium-sized city with precarious working conditions. Further studies can compare the work reality of other teams in cities of different sizes, with better working conditions. Other limitation of this work is the impossibility of work situation improvement and posterior tool application - a study with this magnitude is non-trivial and needs future research. Originality / Value: The difficulties of using the tool mentioned in the available literature were minimized with the use of the reference table, showing that the use of FMEA can become faster and thus spread the tool for risk analysis.

12 November 2020 in Brazilian Journal of Production Engineering
Verified
Journal Article
Open access
PDF file
CSCayllon Victor Nascimento Silva
Cayllon Victor Nascimento Silva
ACAndré Luís de Oliveira Cavaignac
André Luís de Oliveira Cavaignac
JUJhelison Gabriel Lima Uchoa
Jhelison Gabriel Lima Uchoa
Este trabalho objetiva realizar a aplicação da ferramenta FMEA na instalação de energia solar em telhados residenciais de Imperatriz/MA, através de um estudo de caso. Considerando os registros fotográficos realizados, foram identificadas inconformidades com as Normas Regulamentadoras 35, 6, 10 e 18 e também falhas no processo de instalação. Foram definidos três processos para a aplicação da ferramenta FMEA. Os resultados obtidos demonstram que o maior índice de risco envolve um EPI essencial, o capacete, não utilizado por nenhum dos trabalhadores do estudo, que caindo de uma altura significativa pode resultar em óbito. Além dos impactos, o capacete protege inclusive contra choques elétricos. Ficou também constatada a possibilidade de queda de escada e queda do telhado, bem como a ausência total de dispositivos de segurança contra queda. Deste modo, como considerações finais, é proposto um plano de ações corretivas para as falhas dos processos de instalação de energia solar analisados, com a finalidade de assegurar e certificar a segurança dos trabalhadores diretamente envolvidos nesta área.