Ernest K. A. Afrifa

Prof. Ernest K. A. Afrifa


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 February 2020 in Wetlands Ecology and Management
Verified
Journal Article
Closed access
PDF file
BEBernard Ekumah
Bernard Ekumah
FAFrederick Armah
Frederick Armah
EAErnest K. A. Afrifa
Ernest K. A. Afrifa
DADenis Worlanyo Aheto
Denis Worlanyo Aheto
JOJustice Odoiquaye Odoi
Justice Odoiquaye Odoi
AAAbdul-Rahaman Afitiri
Abdul-Rahaman Afitiri

1 February 2024 in Heliyon
Verified
Journal Article
Open access
AAAndoh Kwaku Amponsah
Andoh Kwaku Amponsah
EAErnest K. A. Afrifa
Ernest K. A. Afrifa
PEPaul Kwame Essandoh
Paul Kwame Essandoh
CEChristian Ebere Enyoh
Christian Ebere Enyoh
The contamination of aquatic environments by microplastics (MPs) and their subsequent ingestion by fish continues to be a universal ecological challenge. Although numerous studies have been conducted on the accumulation of MPs by fishes globally, not much work has been done within the major estuaries along the Atlantic Coast. This study explored and characterized microplastics in the gills and gastrointestinal tract in 98 specimens of 10 fish taxa (Sarotherodon melanotheron, Pseudotolithus senegalensis, Gobionellus occidentalis, Ethmalosa fimbriata, Chrysichthys nigrodigitalus, Elops lacerta, Mugil bananesis, Cynoglossus senegalensis, Apsilus fuscus and Galeoides decadactylus) from the Pra Estuary, Ghana. The gastrointestinal contents of the fish were extracted, analysed and characterized using a stereomicroscope fitted with an Attenuated Total Reflectance Fourier Transform Infrared spectroscopy (ATR-FTIR). A total of 529 MP particles were found in the fishes. C. nigrodigitalus recorded the highest MP levels in the gills with an average of 4.83 ± 2.08 items/individual whiles S. melanotheron recorded the highest in the gastrointestinal tract at 9.83 ± 4.63 items/individual. Within the fish, transparent fibrous MPs of size <0.5 mm were the dominate types found. A vertical prevalence of MPs was observed across the feeding and habitat preference of the species suggesting a possible linkage with the ecological niche of fishes. Our findings further demonstrate the need for advance studies on the impacts and level of threat microplastic accumulation pose to the sampled fishes and potential consumers.


26 November 2024 in World
Verified
Journal Article
Open access
PDF file
AAAbdul-Rahaman Afitiri
Abdul-Rahaman Afitiri
EAErnest K. A. Afrifa
Ernest K. A. Afrifa
The consumption of contaminated water contributes to the global burden of diarrhea and other water-borne diseases, especially among young children. While decentralized solar water disinfection treatment systems (hereafter SODIS) remain a viable option to have safe drinking water, our understanding of the effects of household water treatment before use on willingness to accept and adopt a SODIS is limited. In this study, a complementary log-log regression analysis of the compositional and contextual factors that systematically vary with willingness to accept and adopt a SODIS in the Sawla-Tuna-Kalba (STK) district of Ghana was carried out. Based on our findings, a greater proportion of households (97%) are willing to accept and adopt a SODIS. Compositional and contextual factors such as age, marital status, education, religion, and geographical location significantly contribute to households’ willingness to accept and adopt a SODIS in the STK district of Ghana. Households that treat their water before use (66%, p < 0.05) are more likely to accept and adopt a SODIS compared to those that do not treat their water before use. The findings, therefore, suggest that scaling up SODIS in the STK district is sacrosanct and highlight the necessity to analyse compositional and contextual factors influencing willingness to accept and adopt SODIS. Our findings will inform policies and programs aimed at implementing SODIS in the study area to improve the health of communities that rely on poor-quality drinking water sources.

24 March 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
ENEdward Nunoo
Edward Nunoo
ELEmmanuella Lockner
Emmanuella Lockner
EAErnest K. A. Afrifa
Ernest K. A. Afrifa
JEJoseph Essandoh-Yeddu
Joseph Essandoh-Yeddu
ETEric Twum
Eric Twum
JAJOSEPH KWASI ASAFO
JOSEPH KWASI ASAFO
This study expanded the theory of planned behavior to understand factors affecting employee intentions and actual preparedness behaviors in the Ghanaian energy sector. The paper ascertained the effect of psychological factors on employee preparedness intentions and examined whether these factors are mediated by employee’s intentions. Instruments were developed to collect data to assess the variables of the extended theory of planned behavior. Items on the instruments to be measured were structured into three major sections; demographic information on the first part, items of attitude, response efficacy, subjective norms, perceived behavioral control, intention, risk perception, and actual preparedness behaviors on the second part and items of management commitment and management priority on the last section. A pilot test was performed on 15 employees of a sub Gas Distribution Station to determine validity and reliability of the instruments. Content validity was assessed through expert judgment. Individuals with expertise in the field of psychology examined the questionnaires and provided feedback. The instruments were self-administered and data analyzed using the structural equation modelling technique. The novel extended TPB model best-explained employee preparedness intentions and actual emergency preparedness behaviours of employees, confirming the widely held perception that psychological factors do influence employee preparedness intentions. It further suggest employee’s intentions significantly mediate relationship between psychological factors and actual preparedness behaviors. Management must periodically appraise the impact of these factors on employee’s preparedness to make timely informed decisions and may adopt the expanded model to promote employee preparedness for emergencies in the oil and gas industry.

19 May 2025 in Pollutants
Verified
Journal Article
Open access
PDF file
AAAbdul-Rahaman Afitiri
Abdul-Rahaman Afitiri
EAErnest K. A. Afrifa
Ernest K. A. Afrifa
MMMarion Martienssen
Marion Martienssen
The use of ultraviolet (UV) for water disinfection is known for its chemical-free process and with no harmful disinfection by-products. Yet, the disinfection process remains time-consuming, and many studies are limited to disinfection of one or two microbial species. Direct photolytic and glass-embedded TiO2 photocatalytic disinfection of four different bacterial species (Staphylococcus aureus, Salmonella senftenberg, Bacillus subtilis, and Escherichia coli) were assessed using UV-LED radiation with wavelengths of 365 nm. The optimization of the UV disinfection under different masses of the TiO2 photocatalyst was evaluated. Additionally, the order of disinfection of the different bacteria species was assessed. The disinfection effects were measured based on the potential to reduce the number of bacteria species, calculated in colony-forming units/mL and log reduction units. The disinfection of Staphylococcus aureus was enhanced from 1.46 log reduction units in the UV-alone treatment to a high of 5.65 log reduction units in the UV + 0.08 g TiO2 treatment. Regarding Salmonella senftenberg, disinfection was enhanced from 1.26 log reduction units to 3.85 log reduction units in UV-alone experimental treatments and UV + 0.04 g TiO2, respectively. Similarly, an increase in Bacillus subtilis reduction was achieved from a low of 0.69 log reduction units to a high of 2.98 log reduction units in UV-alone treatments and UV + 0.08 g TiO2, respectively. The disinfection of Escherichia coli was enhanced from 2.49 log reduction units (UV-alone treatment) to a high of 6.35 log reduction units (UV + 0.02 g TiO2). The findings provide key implications and new insights into the studied bacteria species and the future application of porous glass-embedded TiO2 photocatalysts to enhance bacteria disinfection using UV light for improved water.