Introduction. Transcranial magnetic stimulation (TMS) is used for treating neurological disorders. Rapid pulses of magnetic field are delivered via a high-current coil situated over the scalp and induce an electric field in the brain. There has been limited fundamental scientific research on TMS and to progress it would be ideal to mimic the electric field of human TMS with mice. Animal models provide good mechanistic insight, but their use is hindered by lack of stimulating coils comparable in focus and intensity with human stimulation. Methods. We outline the engineering challenges in producing appropriate coils. It is unclear what should be optimized in the design of a mouse coil. We model the electric field, heat generation and ring-down time for cylindrical coils and use results to select a coil design consisting of 70 turns of 0.4 mm diameter copper wire wrapped around a 5 mm diameter soft ferrite core. Results and Discussion. While the magnetic flux density scales as the reciprocal of length-scale, the electric field does not scale with length, meaning that a large current is required to mimic the electric field of humans. To maximize electric field, one must minimize the coil’s inductance resulting in reduced ring-down time for the coil and significant heating. A ferrite core allows ring-down time to remain high and reduces heating. Our coil gave 180 mT at 30 V supply, with a temperature increase of 5°C after 1200 pulses at 5 Hz. The B-field below the core has a full-width-at-half-maximum of 6 mm, similar in size to a mouse brain. Conclusions. We have produced a mouse coil that offers increased B-field and reduced heating. There is considerable scope for improving electric field, but further physical analysis may lead to field strength more similar to that obtained in human TMS.
Background. Transcranial Magnetic Stimulation (TMS) is a technique used to treat different neurological disorders non-invasively. A pulsed current to a coil generates a magnetic field (B-field) which induces an electric field (E-field). Underlying biophysical effects of TMS are unclear. Therefore, animal experiments are needed; however, making small TMS coils suitable for mice is difficult and their field strengths are typically much lower than for human sized coils. Objectives/Hypothesis. We aimed to design and demonstrate a mouse-specific coil that can generate high and focused E-field. Methods. We designed a tapered TMS coil of 50 turns of 0.2 mm diameter copper wire around a 5 mm diameter tapered powdered iron core and discharged a 220 μF capacitor at 50 V through it. We measured B-field with a Hall probe and induced E-field with a wire loop. We measured temperature rise with a thermocouple. We applied 1200 pulses of continuous theta burst stimulation (cTBS) and intermittent theta burst stimulation (iTBS) to mouse brain slices and analysed how spontaneous electrical activity changed. Results. The coil gave maximum B-field of 685 mT at the base of the coil and 340 mT at 2 mm below the coil, and maximum E-field 2 mm below the coil of approximately 10 V/m, at 50 V power supply, with a temperature increase of 20 degrees after 1200 pulses of cTBS. We observed no changes in B-field with heating. cTBS reduced frequency of spontaneous population events in mouse brain slices up to 20 minutes after stimulation and iTBS increased frequency up to 20 minutes after stimulation. No frequency changes occurred after 20 minutes. No changes in amplitude of spontaneous events were found. Conclusion. The design generated fields strong enough to modulate brain activity in vitro.
The electrical impedance of samples of mouse brain cortex has been measured between 4.7 kHz and 2.0 MHz. Brain slices of thickness 400 μm were prepared from two mice. Each slice was placed in either normal artificial cerebrospinal fluid or magnesium-free artificial cerebrospinal fluid; the latter induces seizure-like electrical behaviour. A total of 74 samples of cortex of approximate size 2 mm × 2 mm were then cut from these slices. Each sample in turn was placed between two flat Ag/AgCl electrodes and electrical impedance measured with an Agilent E4980A four-point impedance monitor. The measurements showed two regions of significant dispersion. Circuits based on the Cole-Cole and Fricke models, consisting of inductive, nonlinear capacitive and resistive elements were used to model the behaviour. Distributions of values for each circuit element have been determined for the samples prepared in seizing and non-seizing conditions. Few differences were found between the values of circuit elements between the seizing and non-seizing groups.
2 January 2020 in Australasian Journal of Engineering Education
Recently, the University of Waikato introduced a first-year physics course requiring no specific physics or mathematics background, to support degrees in other subjects and allowing maximum diversity in student intake. This course uses the Investigative Science Learning Environment (ISLE) approach in which students develop their own experiments to tackle scientific questions. ISLE has proved successful with mathematically able classes; we have adapted it for a less capable cohort in a regional New Zealand context. We have assessed our approach for 2018 using: pre- and post-course concept tests; performance in exams; a student focus group; analysis of laboratory notebooks and marksheets; interviews with teaching staff; and student comments from the university’s course evaluations. Concept tests showed a mean normalised gain of 0.61. Students did well in the exam. Many students were initially unfamiliar with practical scientific investigation and record keeping but laboratory notebooks showed desired learning outcomes were achieved by the end. Students and staff engaged well with this course. Students’ final grades were not significantly different between genders and between under-represented minority and non-minority students. We cannot yet say whether this approach provides a sufficient platform for progress in engineering but students have learned fundamental practical physical concepts.