MANJUNATHA K

Dr. MANJUNATHA K

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 November 2021 in Proceedings of the Institution of Mechanical Engineers, Part L: Journal of Materials: Design and Applications
Verified
Journal Article
Closed access
PDF file
MKMANJUNATHA K
MANJUNATHA K
GGGiridhara Gaikwad
Giridhara Gaikwad
JNJegadeeswaran Natarajan
Jegadeeswaran Natarajan
PKPraveennath Koppad
Praveennath Koppad
NiCr–Cr3C2 coatings are widely used for high temperature and tribological applications due to their high hardness, oxidation, and wear resistance properties. In the present investigation, an attempt is made to further enhance the hardness and adhesion strength of NiCr–Cr3C2 coatings by reinforcing them with multi-walled carbon nanotubes. The carbon nanotubes (3–7 wt%) with varying weight percentages were mixed with NiCr–Cr3C2 using a planetary ball rolling mill and sprayed on SA213 T12 (T12 alloy steel tube) using a high-velocity oxy-fuel spraying process. The microstructures of mixed powder, coating cross-section, and fractured coating surface were characterized using a scanning electron microscope while X-ray diffraction was used for phase identification in the fractured coating surface. The coated samples were subjected to microhardness and adhesion strength tests according to ASTM E384 and ASTM D4541-09 standards. Out of all coatings, NiCr–Cr3C2/7% carbon nanotube composite coating showed the lowest porosity of 1.17%, highest microhardness, and adhesion strength of 563.8 HV and 55.8 MPa, respectively. A fracture analysis after a pull-off adhesion test revealed adhesion failure for NiCr–Cr3C2 coating and combined adhesion/cohesion failure for NiCr–Cr3C2/7% carbon nanotube composite coating.

20 May 2022 in Proceedings of the Institution of Mechanical Engineers, Part L: Journal of Materials: Design and Applications
Verified
Journal Article
Closed access
MKMANJUNATHA K
MANJUNATHA K
GGGiridhara Gaikwad
Giridhara Gaikwad
DSD Shivalingappa
D Shivalingappa
The thermal power plant boiler tubes experience degradation of their surfaces due to oxidation and molten salt corrosion while working at elevated temperatures. The formation of protective coating layers can overcome such surface degradation. In the current research, protective coated layers composed of Cr 3 C 2 -25% NiCr/Carbon nanotube coatings are deposited on the ASTM SA-213T12 boiler tube substrate by the High-Velocity Oxy-Fuel (HVOF) thermal method. The coating powder Cr 3 C 2 -25%NiCr is reinforced with 3, 5 and 7 wt% of Multi-Wall Carbon Nano-Tube (MWCNT) prior to deposition. The uncoated and coated specimens are evaluated for hot corrosion behaviour in the molten salt environment (Na 2 SO 4 + 60%V 2 O 5 ) for 50 cycles, constituting 1 h of heating at 600 °C. Thermogravimetric analysis is used to investigate the kinetics of hot corrosion behaviour in both coated and uncoated samples. Coatings are characterized with the help of X-ray diffraction and Scanning Electron Microscope/Energy Dispersive Spectroscopy (SEM/EDS) techniques. Microstructural investigations with the help of SEM/EDS and X-ray diffraction of coated and uncoated samples revealed that 7 wt% of CNT coated samples minimized the voids and pores of the coatings, leading to better interlocking with the substrate surface. Furthermore, it is observed in the studies that the appreciable corrosion resistance of 7 wt% of CNT composite coatings is higher than 3 and 5 wt% of CNT-coated and uncoated samples.

25 March 2025 in Journal of Bio- and Tribo-Corrosion
Verified
Journal Article
Closed access
PDF file
MSM. B. Swathi
M. B. Swathi
DGD. P. Girish
D. P. Girish
MDM. H. Dinesh
M. H. Dinesh
KRKeshavamurthy Ramaiah
Keshavamurthy Ramaiah
MKMANJUNATHA K
MANJUNATHA K

1 June 2025 in Surface Engineering
Verified
Journal Article
Closed access
CVC. G. Vijay
C. G. Vijay
BKB. M. Santhosh Kumar
B. M. Santhosh Kumar
MKMANJUNATHA K
MANJUNATHA K
MDM. H. Dinesh
M. H. Dinesh
The High Velocity Oxygen-Fuel (HVOF) process has recently increased interest in tungsten carbide (WC) coatings for enhancing surface properties of lightweight alloys such as Al6061, widely used in aerospace, automotive, and industrial applications. In this research work, an investigation into the microstructural characteristics, hardness improvements, Coefficient of friction (COF), and reductions in wear rate of the WC coatings applied at a thickness of 100 microns and 200 microns on Al6061 alloy is discussed. Scanning electron micrographs show a dense and uniform WC layer with minimal porosity. EDAX confirmed the presence of WC and supporting elements. In the case of the 100-micron coating, there was an increase of 337.5% over the base alloy, and in the case of the 200-micron coating, the improvement was 525%. The COF was reduced by 22.5% and 30.9%, and the wear rate decreased by 25% and 41.6% for the respective coating thicknesses.

1 October 2025 in Surfaces and Interfaces
Verified
Journal Article
Closed access
VGVijay C G
Vijay C G
MKMANJUNATHA K
MANJUNATHA K
SMSanthosh Kumar B M
Santhosh Kumar B M
GPGirish D P
Girish D P
DHDinesh M H
Dinesh M H

5 December 2024 in Surface Engineering
Verified
Journal Article
Closed access
MKMANJUNATHA K
MANJUNATHA K
RDRoopa D
Roopa D
In this work, a multilayer Chemical Vapour Deposition (CVD) coating over a base tool material is developed, and its performance in cutting tailored hard EN8 steel is investigated. Using atmospheric pressure chemical vapor deposition, the TiN-TiCN-Al2O3-TiN coating is created on the TNMG 160408 base material. During deposition, 900 m-Torr of deposition pressure and 800 °C of temperature are maintained. Energy-dispersive X-ray analysis (EDAX) is used to inspect the coated instrument to ensure the desired chemical composition is present. According to experimental findings, when cutting speed increases, surface roughness and thrust force decrease. When feed rate and depth of cut are adjusted in tandem with cutting speed, tool wear increases as cutting speed increases. ANOVA variance analysis is carried out while taking into account the maximum dependence of temperature, torque, tool wear, surface roughness, thrust force, and cutting speed on feed rate. Chip analysis is performed at varying speeds of 140, 200, and 260 mm/min, increasing the working conditions results in longer continuous chips. Chips with helical and tubular shapes can be created at cutting rates of 200 mm/min and a depth of cut of 1 mm, respectively.