Cardiovascular reactivity to stress and α‐adrenergic receptor (α‐AR) function may contribute to the development of hypertension. As Black Americans have an increased risk of hypertension, we evaluated associations between α1A‐AR (Arg492Cys), α2A‐AR (‐1291C/G), and α2B‐AR (Ins/Del301‐303) gene variants and cardiovascular reactivity in 500 normotensive Black youth. Heart rate, preejection period, total peripheral resistance, and blood pressure were measured during cold and psychological stress. The Arg492Cys polymorphism in the α1A‐AR gene was associated with heart rate reactivity to stress, but the association depended on sex. The ‐1291C/G promoter polymorphism in the α2A‐AR gene was associated with vascular reactivity to stress; vasoconstriction increased as a linear function of the number of copies of the variant G allele. Thus, specific associations emerged between genetic variations in α‐Ars and cardiovascular reactivity in young Blacks.
1 October 2014 in Journal of the American Society of Hypertension
The Welch Allyn Pro BP 2000, an automated sphygmomanometer, was subjected to ANSI/AAMI/ISO testing. The protocol used was the same-arm sequential procedure described in the ANSI/AAMI/ISO 2013 Standard. Eight-eight (53 adults and 35 children aged 3–12 years old) patients completed testing successfully. Arm circumferences ranged from 15 to 49.5 cm. Seven different cuff sizes were used, including two long cuffs. All requirements for age, sex, blood pressure (BP), and cuff sizes were fulfilled. The mean±SD was −2.8±6.37 mmHg for systolic BP for criterion 1 and −3.6±6.14 mmHg for diastolic BP. The SD for criterion 2 were 5.29 for systolic BP and 5.75 for diastolic BP. All data passed the Standard’s requirements. The Pro BP 2000 uses an accurate inflationary algorithm. The time for each inflation/deflation cycle is short, thus improving patient comfort. There is also arrhythmia detection to caution the use of BP values obtained during irregular heart rhythms. The algorithm for the professional-grade Pro BP 2000 is also contained in the Home BP 1700, targeted for home use. This encourages out-of-office self-measurement. The healthcare professional can be confident that the values obtained at different sites are comparable.
5 April 2020 in The Journal of Clinical Hypertension
Most automated sphygmomanometers use oscillometric algorithms. Motion, either patient‐based or environmental, will affect the ability of a device to record an accurate blood pressure (BP). Members of the Association for the Advancement of Medical Instrumentation (AAMI) Sphygmomanometer Committee have been studying this problem for more than a decade. The AAMI TIR44 was the first publication to address the challenges of motion tolerance. The concepts described in TIR44 have led to the development of a draft of ISO 81060‐4, a new standard for testing devices for which the manufacturer wishes to claim motion tolerance. The current ISO 81060‐2 addresses both stress testing and 24‐hour ambulatory BP monitoring. Recent publications have reported on testing of devices in response to voluntary and involuntary patient motion. The ISO 81060‐4 will address testing in the presence of patient transport by ground, fixed‐wing, and rotary (helicopter) ambulances. The protocol will utilize noise profiles recorded under those three conditions. The profiles will be digitally stored on a library with free access. The proposed testing will be performed using patient simulators introducing the noise library files into known BP oscillometric envelopes. The specifications of the data capture and playback devices are specified, as is the evaluation statistical testing. The authors expect that the final draft will be published in 2020.
The aim of this report is to describe a new device that can validate, by automated auscultation, individual blood pressure (BP) readings taken by automated sphygmomanometers.The Accutension Stetho utilizes a smartphone application in conjunction with a specially designed stethoscope that interfaces directly into the smartphone via the earphone jack. The Korotkoff sounds are recorded by the application and are analyzed by the operator on the screen of the smartphone simultaneously with the images from the sphygmomanometer screen during BP estimation. Current auscultatory validation standards require at least 85 subjects and strict statistical criteria for passage. A device that passes can make no guarantee of accuracy on individual patients. The Accutension Stetho is an inexpensive smartphone/stethoscope kit combination that estimates precise BP values by auscultation to confirm the accuracy of an automated sphygmomanometer’s readings on individual patients. This should be of great value for both professional and, in certain circumstances, self-measurement BP. Patients will avoid both unnecessary treatment and errors of underestimation of BP, in which the patient requires therapy. The Stetho’s software has been validated in an independent ANSI/AAMI/ISO standard study. The Stetho has been shown to perform without difficulty in multiple deflation-based devices by many manufacturers.