Mustafa Şeker

Dr. Mustafa Şeker

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 July 2021 in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
Verified
Journal Article
Closed access
MŞMustafa Şeker
Mustafa Şeker
Long-term load forecasting is a significant and complex topic in electric distribution systems. Forecasters is need to proper forecasting methodologies and smart solutions to minimize complexity. In this study, regional long-term load forecasting is presented, for Sivas province of Turkey, taking into account the development plan of the municipality, and subscriber profiles. Firstly, the municipality development plan is divided into regions of similar load characteristics. The load demand values of each region are defined mathematically using the S curve. The optimal parameter values of the S curve are calculated using meta-heuristic methods such as Genetic Algorithm (GA), Grey Wolf Optimization (GWO) and Harris Hawk Optimization (HHO). The obtained results are compared with the results of the econometrics-based (top-to-bottom) approach and actual consumer projection. The consumption values between 2004 and 2014 are used for parameter estimation of S curves. The consumption values obtained as the result of analysis the period between 2015 and 2018 were selected as test data. The result is shown that S curve-based regional demand forecast demonstrated more convenient results using the HHO algorithm with statistical values of RE = 1.3362, MAE = 1.5145, RMSE = 1.80385 and STD = 2.122 can be applied to the forecast regional electricity consumption. The proposed method is simple and can be easily applied to forecast the total consumption of the power load for a province any load forecasting region. The presented approach can be used to define the future projections of electricity distribution systems and determine the correct investment strategies.

19 December 2017 in Elektronika ir Elektrotechnika
Verified
Journal Article
Closed access
PDF file
MŞMustafa Şeker
Mustafa Şeker
AMArif Memmedov
Arif Memmedov
RHRafael Huseyinov
Rafael Huseyinov
SKSerdar Kockanat
Serdar Kockanat
During the recent years, with its increasing steel production, Turkey has succeeded to become one of the ten biggest steel producer countries in the world. In Turkey, there are 3 integrated plants and 27 Electric Arc Furnace (EAF) plants in operation for iron-steel production. 71,3 % of the steel products was produced by EAF plants and also it is planned for new plants to produce with arc furnaces. In this study, power quality problems caused by 60MVA arc furnace at Sivas Iron and Steel Incorporated Company (SIDEMIR), have been examined by HIOKI 3197 and Chauvin Arnoux(CA) 8332B power quality analysers according to IEC 61000-4-30 standards. In addition, with equivalent circuit model designed by utilizing Electromagnetic Transient Program(EMTP) software, possible harmonic effects on the electricity grid have been evalauted and by determining power quality problems caused by EAF-60 furnace, solution offers were presented in order to improve power quality. DOI: http://dx.doi.org/10.5755/j01.eie.23.6.19691

5 April 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MŞMustafa Şeker
Mustafa Şeker
EMRE ÜNSALEMRE ÜNSAL
EMRE ÜNSAL
Ahmet AksözAhmet Aksöz
Ahmet Aksöz
MDMahir DURSUN
Mahir DURSUN
The control of nonlinear systems cannot be effectively achieved using linear mathematical methods. This paper introduces a novel mathematical model to characterize the voltage–current (V–I) characteristics of the electric arc furnace (EAF) melting process, incorporating experimental field data for validation. The proposed model integrates polynomial curve fitting, the modified Heidler function, and double S-curves, with the grey wolf optimization (GWO) algorithm applied for parameter optimization, enhancing accuracy in predicting arc dynamics. The performance of the model is compared against the exponential, hyperbolic, exponential–hyperbolic, and nonlinear resistance models, as well as real-time measurement data, to assess its effectiveness. The results show that the proposed model significantly reduces voltage and current harmonic distortion compared to existing models. Specifically, the total harmonic distortion (THD) for voltage is reduced to 2.34%, closely matching the real-time measured value of 2.30%. Similarly, in the current spectrum, the proposed model achieves a significant reduction in third harmonic distortion and a THD of 11.40%, compared to 13.76% in real-time measurements. Consequently, a more precise characterization of the EAF behavior enables more effective mitigation of harmonics and vibrations, enhancing the stability and power quality of the electrical networks to which they are connected.

26 July 2023 in Gospodarka Surowcami Mineralnymi - Mineral Resources Management
Verified
Journal Article
Closed access
MŞMustafa Şeker
Mustafa Şeker
NKNeslihan Ünal Kartal
Neslihan Ünal Kartal
SKSelin Karadirek
Selin Karadirek
CGC. Bertan Güllüdağ
C. Bertan Güllüdağ

29 September 2026 in International Journal of Energy Studies
Verified
Journal Article
Closed access
ŞTŞura Tutcu
Şura Tutcu
MŞMustafa Şeker
Mustafa Şeker
In this study, Particle Swarm Optimization (PSO), Grey Wolf Optimizer (GWO), and Crested Porcupine Optimizer (CPO) algorithms were comparatively evaluated for global maximum power point tracking in photovoltaic systems under standard test and partial shading conditions. The MATLAB/Simulink model consists of four series-connected 250 W PV modules, bypass diodes, a boost DC–DC converter, a PWM generator, and an MPPT controller that directly determines the duty cycle of the converter. The algorithms were tested under three operating scenarios: standard test conditions, mild partial shading, and severe partial shading. To ensure a fair comparison, identical PV system parameters, converter settings, duty-cycle limits, and a common true GMPP reference were used for all algorithms. The performance of each method was assessed using steady-state average power, common-reference-based MPPT efficiency, settling time, steady-state power oscillation, and energy yield. Under standard test conditions, PSO showed the most balanced performance in terms of tracking accuracy and low oscillation, achieving a steady-state power of 998.972 W. Under mild partial shading conditions, CPO provided the best combined performance, with a steady-state power of 485.000 W, a power oscillation of 0.000055%, and a settling time of 0.15273 s. Under severe partial shading conditions, GWO achieved the steady-state power closest to the common GMPP reference, with 363.798 W, whereas PSO provided the fastest response and the lowest steady-state oscillation. The results indicate that no single algorithm is superior under all operating conditions. Therefore, the most suitable MPPT method should be selected by jointly considering tracking accuracy, convergence speed, steady-state stability, and application-specific requirements.