Mehman Ahmadli

Mr. Mehman Ahmadli

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2025 in Journal of Offshore Mechanics and Arctic Engineering
Verified
Journal Article
Closed access
PDF file
MAMehman Ahmadli
Mehman Ahmadli
TGTor Berge Stray Gjersvik
Tor Berge Stray Gjersvik
SSSigbjørn Sangesland
Sigbjørn Sangesland
R.M. Chandima RatnayakeR.M. Chandima Ratnayake
R.M. Chandima Ratnayake
The subsea valve system is a key part of the subsea control system (SCS), which maintains the reliability of the subsea production system (SPS). With its current state, subsea valve systems cannot cope with the requirements to transition to the all-electric system (AES) and application of the SPS to deep- and ultra-deep-water locations. The primary reason is related to the limitations of the currently used coating material of subsea valve internals, tungsten carbide (WC), in terms of high operating pressures, sand production, and efficiency. With its expected low friction and high wear resistance, polycrystalline diamond compact (PDC) material is offered to replace WC as a top contact material in subsea valves. For this objective, PDC material's friction and wear behavior are investigated experimentally. The experimental section of the research involves tests with a reciprocating pin-on-flat tribometer, surface roughness measurements, and microscopical analysis of wear. Alongside PDC material, WC material is exposed to the same test process and conditions throughout the research for comparative analysis. The results show that comparing WC material in dry conditions, PDC material offers 61% friction reduction and 99.5% wear reduction; in lubricated conditions, it offers 40% friction reduction and 58% wear reduction. The findings highlight the potential impacts of this study on minimizing power usage for hydraulic and electric subsea actuators which consequently contributes to the reliability of the SCS and fills the existing research gap.

11 November 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
MAMehman Ahmadli
Mehman Ahmadli
TGTor Berge Stray Gjersvik
Tor Berge Stray Gjersvik
SSSigbjørn Sangesland
Sigbjørn Sangesland
Produced well flow is controlled through valves placed in the Christmas tree. Being mostly gate-type valves, they isolate the well from the surface when commanded or automatically in an emergency. The reliability of these valves is essential for subsea wells, as maintenance and replacement involve high cost, time, and HSE risks. Their design must withstand harsh conditions such as high temperature, pressure, solid particles, and corrosive environments. However, failures caused by leakage, cold welding, and the erosion of sealing elements are still common. These issues motivated the initial stage of this research, which experimentally showed that replacing the current tungsten carbide (WC) coating with polycrystalline diamond compact (PDC) material reduces friction and wear due to its high hardness and thermal stability. Based on these results, a 3D subsea gate valve model was developed and simulated in Ansys Fluent 2024 R2 under API slurry test conditions using the Oka erosion and Discrete Phase Models. A comparative analysis of WC and PDC coatings for a 5-inch gate valve exposed to a 2% sand slurry (250–400 μm) showed that PDC reduces the erosion depth by 77.6% and extends the valve lifetime by 4.5 times. The findings support the use of PDC for improved erosion resistance in subsea valve applications.

10 December 2025 in Materials
Verified
Journal Article
Open access
PDF file
MAMehman Ahmadli
Mehman Ahmadli
TGTor Berge Stray Gjersvik
Tor Berge Stray Gjersvik
SSSigbjørn Sangesland
Sigbjørn Sangesland
Produced well flow is controlled through valves placed in the Christmas tree. Being mostly gate-type valves, they isolate the well from the surface when commanded or automatically in an emergency. The reliability of these valves is essential for subsea wells, as maintenance and replacement involve high cost, time, and HSE risks. Their design must withstand harsh conditions such as high temperature, pressure, solid particles, and corrosive environments. However, failures caused by leakage, cold welding, and the erosion of sealing elements are still common. These issues motivated the initial stage of this research, which experimentally showed that replacing the current tungsten carbide (WC) coating with polycrystalline diamond compact (PDC) material reduces friction and wear due to its high hardness and thermal stability. Based on these results, a 3D subsea gate valve model was developed and simulated in Ansys Fluent 2024 R2 under API slurry test conditions using the Oka erosion and Discrete Phase Models. A comparative analysis of WC and PDC coatings for a 5-inch gate valve exposed to a 2% sand slurry (250–400 μm) showed that PDC reduces the erosion depth by 77.6% and extends the valve lifetime by 4.5 times. The findings support the use of PDC for improved erosion resistance in subsea valve applications.