The ability of patients to improve glycemic control depends partly on their ability to interpret and act on blood glucose results. We investigated whether switching people with diabetes to blood glucose meters (BGMs) featuring a color range indicator (CRI) could improve glycemic control compared to remaining on their current BGM without color. 163 adults with type 1 (T1D) or type 2 diabetes (T2D) and a hemoglobin A1c (A1c) of 7.5-11% were randomized to: One Touch Verio™ (Verio), OneTouch Verio Flex™ (Flex), or controls remaining on their current BGM. Diabetes nurses had standard conversations about diabetes management with all subjects at baseline. No changes in medication, insulin dosing, or SMBG frequency were recommended. After 12 weeks, subjects who switched to Verio or Flex meters with CRI (n = 108) had a mean change in A1c 0.36% lower than controls (n = 55) (P = .017). A1c reductions were greatest in T1D subjects (n = 45), with a decrease of 0.50% (P = .004). T1D subjects using Verio meters (n = 25) contributed a 0.59% reduction compared to controls (P < .008), whereas T1D subjects using Flex meters (n = 20) had a clinical meaningful reduction in A1c of 0.40% without reaching statistical significance (P > .05). Verio and Flex users reported taking more action and easier understanding of diabetes management compared to previous BGMs. This study demonstrated that switching patients to BGMs featuring a CRI resulted in improvements in glycemic control compared to subjects using currently marketed BGMs that do not use a CRI. Registration: Clinicaltrials.gov NCT02929654 https://clinicaltrials.gov/ct2/show/NCT02929654
Background: There is a perception that patients with diabetes struggle to produce sufficient blood to fill glucose test strips, including strips with 1-µL fill requirements. The purpose of this study was to determine the volume of blood expressed when these patients perform routine fingersticks using their own lancing device and sampling technique and to evaluate the relationship between blood volume and pain. Methods: Sixty-four patients (type 1 or type 2 diabetes) performed 8 fingersticks using their own lancing device and preferred depth setting and lancing technique. Eight different commercially available lancing systems were used (8 patients/system). Blood volume and perceived pain were recorded after each fingerstick. Results: The mean blood volume across all patients was 3.1 µL (512 fingersticks), with 97% of patients expressing a mean of ≥1.0 µL of blood. There was no correlation between pain response and the volume of blood expressed. Nearly all patients agreed that they could easily and comfortably obtain a 1-µL blood sample, and most patients actually preferred a larger drop size to ease sampling and avoid wasting strips. Conclusion: These results provide evidence across 8 lancing systems that challenge the current perceptions that patients with diabetes struggle to produce sufficient blood samples to fill most test strips, including those with 1-µL fill requirements, and that obtaining larger volumes of blood is more painful. These results are consistent with the previous literature suggesting that patients derive no real benefits from very low strip volumes and generally prefer a blood drop size that enables them to confidently fill their test strip.
20 December 2015 in Journal of Diabetes Science and Technology
Cloud-connected diabetes applications enable health care professionals (HCPs) to monitor patient progress and offer the potential for remote consultations. OneTouch Reveal (OTR) is a cloud-based web application that aggregates data from blood glucose (BG) meters or insulin pumps and provides analytics to help patients and HCPs make more informed treatment and lifestyle decisions. This study assessed the experience of patients using OTR and the OneTouch Verio (OTV) BG meter and determined the extent of changes in glycemic control. Subjects with T1DM (23) or T2DM (17) uploaded BG meter results to OTR for 12 weeks. HCPs remotely reviewed progress using OTR and delivered telephone consultations at 4 and 8 weeks based on OTR insights. After 12 weeks, mean HbA1c decreased by 0.4% (P < .001) and 25% of subjects had a reduction of ≥1.0%. Reduction in HbA1c was similar in subjects with T1DM and T2DM, although subjects with T1DM started with higher baselines. In subjects with T2DM, mean BG decreased significantly from 175 to 161 mg/dl (P < .001) with the percentage of above-range BG results decreasing from 33% to 24%. 80% of subjects confirmed OTR detected out-of-range glucose patterns and 84% of these subjects were able to correct the underlying pattern to get BG back in-range. OTR web application in combination with the OTV meter helped subjects with T1DM and T2DM effectively manage their diabetes and was associated with improved BG control over 12 weeks. Real-time visibility to subject data may help HCPs deliver focused and effective remote consultations.
1 July 2013 in Journal of Diabetes Science and Technology
This study aimed to evaluate the performance of a glucose pattern recognition tool incorporated in a blood glucose monitoring system (BGMS) and its association with clinical measures, and to assess user perception and understanding of the pattern messages they receive. Participants had type 1 or type 2 diabetes mellitus and were self-adjusting insulin doses for ≥1 year. During a 4-week home testing period, participants performed ≥6 daily self-tests, adjusted their insulin regimen based on BGMS results, and recorded pattern messages in the logbook. Participants reflected on usability of the pattern tool in a questionnaire. Study participants (n = 101) received a mean ± standard deviation of 4.5 ± 1.9 pattern messages per week (3.6 ± 1.8 high glucose patterns and 0.9 ± 1.3 low glucose patterns). Most received ≥1 high (96.5%) and/or ≥1 low (46.0%) pattern message per week. The average number of high- and low-pattern messages per week was associated with higher and lower, respectively, baseline hemoglobin A1c (p < .01) and fasting plasma glucose (p < .05). Participants found high- and low-pattern messages clear and easy to understand (84.2% and 83.2%, respectively) and considered the frequency of low (82.0%) and high (63.4%) pattern messages about right. Overall, 71.3% of participants indicated they preferred to use a meter with pattern messages. The on-device Pattern tool identified meaningful blood glucose patterns, highlighting potential opportunities for improving glycemic control in patients who self-adjust their insulin.
11 July 2016 in Journal of Diabetes Science and Technology
We previously demonstrated that people with type 2 diabetes (T2DM) can improve their ability to categorize blood glucose (BG) results into low, in range, or high glycemic ranges after experiencing a color range indicator (CRI or ColorSure™ Technology) in a single meter. This study examined whether a CRI was effective in people with type 1 (T1) or T2DM when used in 3 glucose meters. A total of 179 subjects (139 T2DM and 40 T1DM) classified BG values as low, in range, or high based on individual current knowledge. Subjects then experienced the CRI which showed whether different BG values were low, in range, or high. After CRI interaction, subjects repeated the classification. Following interaction with the CRI, subjects significantly improved their ability to categorize BG results into low, in range, and high glycemic ranges by 27.9% (T2DM) and 27.2% (T1DM) (each P < .001). Improvement was not accompanied by an increase in time spent categorizing results. There was no difference in classification ability between subjects with T1 or T2DM. There was also no correlation between HbA1c, numeracy level, test frequency, or duration of diabetes and the ability to correctly classify results. Subjects agreed the CRI feature helped them easily interpret glucose values and improved their awareness of glucose ranges. Interaction with a CRI improved the ability of subjects with T1 and T2DM to interpret and categorize BG values into recommended glycemic ranges, irrespective of the glucose meter providing the CRI insights.