Pascal Bailly

Mr. Pascal Bailly

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 June 2008 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Closed access
PDF file
LFLoïc Fin
Loïc Fin
JDJoël Daouk
Joël Daouk
JMJulie Morvan
Julie Morvan
PBPascal Bailly
Pascal Bailly
IEIsabelle El Esper
Isabelle El Esper
MMMarc-Etienne Meyer
Marc-Etienne Meyer

1 March 2009 in Acta Radiologica
Verified
Journal Article
Closed access
JDJ. Daouk
J. Daouk
LFL. Fin
L. Fin
PBPascal Bailly
Pascal Bailly
MMM.-E. Meyer
M.-E. Meyer
Background: Respiratory motion causes uptake in positron emission tomography (PET) images of chest and abdominal structures to be blurred and reduced in intensity. Purpose: To compare two respiratory-gated PET binning methods (based on frequency and amplitude analyses of the respiratory signal) and to propose a “BH-based” method based on an additional breath-hold computed tomography (CT) acquisition. Material and Methods: Respiratory-gated PET consists in list-mode (LM) acquisition with simultaneous respiratory signal recording. A phantom study featured rectilinear movement of a 0.5-ml sphere filled with 18F-fluorodeoxyglucose (18F-FDG) solution, placed in a radioactive background (sphere-to-background contrast 6:1). Two patients were also examined. Three figures of merit were calculated: the target-to-background ratio profile (TBRP) in the axial direction through the uptake (i.e., the sphere or lesion), full-width-at-half-maximum (FWHM) values, and maximized standard uptake values (SUVmax). Results: In the phantom study, the peak TBRP was 0.9 for non-gated volume, 1.83 for BH-based volume, and varied between 1.13 and 1.73 for Freq-based volumes and between 1.34 and 1.66 for Amp-based volumes. A reference volume (REF-static) was also acquired for the phantom (in a static, “expiratory” state), with a peak TBRP at 1.88. TBRPs were computed for patient data, with higher peak values for all gated volumes than for non-gated volumes. Conclusion: Respiratory-gated PET acquisition reduces the blurring effect and increases image contrast. However, Freq-based and Amp-based volumes are still influenced by inappropriate attenuation correction and misregistration of mobile lesions on CT images. The proposed BH-based method both reduces motion artifacts and improves PET-CT registration.

11 June 2009 in Medical Physics
Verified
Journal Article
Closed access
PDF file
LFLoïc Fin
Loïc Fin
PBPascal Bailly
Pascal Bailly
JDJoël Daouk
Joël Daouk
MMMarc‐Etienne Meyer
Marc‐Etienne Meyer

16 February 2011 in International Journal of Imaging Systems and Technology
Verified
Journal Article
Closed access
PDF file
MRMireille Rmeily-Haddad
Mireille Rmeily-Haddad
OBOlivier BALEDENT
Olivier BALEDENT
SSSouraya Stoquart-ElSankari
Souraya Stoquart-ElSankari
JSJean-Marie Sérot
Jean-Marie Sérot
PBPascal Bailly
Pascal Bailly
MMMarc-Etienne Meyer
Marc-Etienne Meyer

1 December 2015 in Physica Medica
Verified
Journal Article
Closed access
JDJoël Daouk
Joël Daouk
PBPascal Bailly
Pascal Bailly
MMMarc-Etienne Meyer
Marc-Etienne Meyer

1 August 2014 in Nuclear Medicine Communications
Verified
Journal Article
Closed access
APAudrey Pépin
Audrey Pépin
JDJoël Daouk
Joël Daouk
PBPascal Bailly
Pascal Bailly
SHSébastien Hapdey
Sébastien Hapdey
MMMarc-Etienne Meyer
Marc-Etienne Meyer