Pawel Regucki

Prof. Pawel Regucki

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 December 2021 in Buildings
Verified
Journal Article
Open access
PDF file
Marcin BrzezickiMarcin Brzezicki
Marcin Brzezicki
PRPawel Regucki
Pawel Regucki
Jacek KasperskiJacek Kasperski
Jacek Kasperski
A building’s facade is its main interface with the external environment, as it controls almost all energy flows in the building—losses and gains. In this context, the most recent invention of adaptive façades allows for the introduction of an optimized system for both daylight management and electrical energy production. The authors of the presented paper propose a novel adaptive façade system that is equipped with vertical shading fins of 1 × 4 m that are covered with PV panels. The fins are kinetic and rotate around a vertical axis in order to optimize solar irradiation for producing electricity. The presented adaptive façade is analyzed in two stages. Firstly, the number of vertical shading fins is optimized in the context of useful daylight illuminance (UDI) and daylight glare probability (DGP) using Radiance-cored software. Next, two scenarios of PV installation are verified for fixed and the Sun-tracking solution. The results show that the Sun-tracking system is more efficient than the fixed one, but electricity production is only increased by 3.21%. The reason for this is the fact that—while following the Sun’s azimuth position—fins shade each other and reduce the effective area of the adjacent PV panels. Based on this, the authors conclude that the Sun-tracking system might be justified due to its protective or decorative function and not because of its improved effectiveness in generating electrical energy.

22 December 2020 in Science and Technology for the Built Environment
Verified
Journal Article
Closed access
Marcin BrzezickiMarcin Brzezicki
Marcin Brzezicki
PRPawel Regucki
Pawel Regucki
This paper concentrates on the issues of daylight optimization in an office building using external shading fins/panels. Vertical shading elements are seen as an important tool of daylight management in buildings, especially when the façade is fully glazed. This enables guiding daylight deep into the room, simultaneously reducing the impact of direct solar radiation. The presented analysis illustrates the impact of the different spacing of vertical fins on the user’s visual comfort. The analyzed case studies feature different numbers of panels on a south-facing façade located on the 51 deg. latitude in Wrocław, Poland. The daylight calculations were done using De Luminae software (the DL-Light platform) with SketchUp. The analysis of the useful daylight illuminance (UDI) is combined with a caflculation of the maximum drag force acting on the panels installed outside. The research has been conducted taking into account various wind directions. The results show that it is possible to indicate the optimal number of installed vertical fins in order to help increase visual comfort and minimize drag force.

17 October 2019 in Heat Transfer Engineering
Verified
Journal Article
Closed access
PRPawel Regucki
Pawel Regucki
MLMarek Lewkowicz
Marek Lewkowicz
RKRenata Krzyzynska
Renata Krzyzynska
The paper presents the thermal-flow study of a closed cooling system with special emphasis on the working parameters of natural draft wet cooling towers. The authors analyze the possibility of the improvement of the overall cooling efficiency of a closed cooling system consisting of several cooling towers by the proper redistribution of cooling water between individual units. The problem of the optimal redistribution of circulating water between cooling towers is formulated as a mathematical issue involving finding the extrema of the multivariate function with constraints fixing the total mass flow rate of cooling water circulated in the hydraulic installation and the ranges of the hydraulic loads of individual cooling towers. The optimization process requires information about the individual characteristics of each cooling tower, which is achieved by experimental measurements done on real objects. The research done inside the cooling towers enables the identification of the heat and mass transfer processes across its radius. Next, these characteristics are used to calculate the optimal cooling water flow rates to the cooling towers, giving the highest possible mean cooling water temperature drop in the system.

1 October 2016 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
PRPawel Regucki
Pawel Regucki
BEB Engler
B Engler
ZSZ Szeliga
Z Szeliga
The paper presents a mathematical model describing the changes in SO4 2- ions concentration in a closed system of cooling water circulation in a professional power plant due to the new restrictions posed on industrial emissions by EU and Polish government regulations [1]. Analyzing the behavior of the numerical solutions of the model Authors could determine the optimal volumetric flow rate of wastewater depending on the current configuration of operating power units in a professional power plant.

7 November 2017 in E3S Web of Conferences
Verified
Conference Paper
Open access
PDF file
PRPawel Regucki
Pawel Regucki
MLMarek Lewkowicz
Marek Lewkowicz
MKMałgorzata Kucięba
Małgorzata Kucięba
The paper presents a mathematical model allowing one to study series-parallel hydraulic systems like, e.g., the cooling system of a power boiler's auxiliary devices or a closed cooling system including condensers and cooling towers. The analytical approach is based on a set of non-linear algebraic equations solved using numerical techniques. As a result of the iterative process, a set of volumetric flow rates of water through all the branches of the investigated hydraulic system is obtained. The calculations indicate the influence of changes in the pipeline's geometrical parameters on the total cooling water flow rate in the analysed installation. Such an approach makes it possible to analyse different variants of the modernization of the studied systems, as well as allowing for the indication of its critical elements. Basing on these results, an investor can choose the optimal variant of the reconstruction of the installation from the economic point of view. As examples of such a calculation, two hydraulic installations are described. One is a boiler auxiliary cooling installation including two screw ash coolers. The other is a closed cooling system consisting of cooling towers and condensers.

13 May 2025 in Sustainability
Verified
Journal Article
Open access
PDF file
Marcin BrzezickiMarcin Brzezicki
Marcin Brzezicki
Joanna JablonskaJoanna Jablonska
Joanna Jablonska
PRPawel Regucki
Pawel Regucki
DBDominik Blonski
Dominik Blonski
This study investigates the effectiveness of sloped horizontal shading fins in enhancing visual comfort, electricity generation, and acoustic attenuation in a south-facing office room in Wrocław, Poland (51° latitude). A simulation-based approach combined Radiance daylight simulations, PV energy modeling, and graphical acoustic analysis. Four fin configurations were tested to identify the optimal design. The results indicate that Variant 3, featuring two 1 m wide fins inclined at 45°, achieved the best overall performance, increasing UDI300–3000/168 from 53.1% to 95.8%, reducing DGP from 50% to 27%, and enabling an estimated annual electricity production of 4.67 MWh. Additionally, applying sound-absorbing material on the shaded side of the fins significantly reduced reflective acoustic wave bounces, significantly reducing façade-exposed noise. This multifunctional solution demonstrates a practical and scalable strategy for improving office environmental quality in temperate climates, contributing to energy efficiency, acoustic comfort, and visual well being.