With the widespread adoption of smart mobile devices, smartphone-based indoor positioning technology has become a significant area of research. This study proposes a collaborative adaptive multi-source data fusion method for indoor positioning, utilizing the inherent multi-sensor capabilities of smartphones. In the offline phase, a Multi-Layer Perceptron (MLP) is trained using collected Wi-Fi fingerprint data. Specifically, we recorded 114 fingerprint locations in Scenario 1 and 99 in Scenario 2, each containing 20,000 fingerprint data sets. During the online phase, the system collects real-time Wi-Fi fingerprint data and matches it against the trained dataset. Subsequently, the user’s step length and direction data are integrated into a Pedestrian Dead Reckoning (PDR) algorithm to estimate positions within complex indoor environments. Finally, we apply an Adaptive Extended Kalman Filter (AEKF), which adjusts weights to further improve positioning accuracy. Experimental results demonstrate that the AEKF method reduces root-mean-square errors (RMSE) to 0.763m and 0.884m in scenarios with different complexities, enhancing accuracy by 10.13% and 30.17% compared to traditional EKF methods. Comparative analysis with mainstream algorithms further highlights the advantages of AEKF, achieving maximum accuracy improvements of up to 36.54%. These findings underscore the effectiveness of our approach in advancing indoor positioning technology for mobile applications, offering practicality and cost-effectiveness without requiring additional hardware.
With the long-term dependence of humans on ore-based energy, underground mines are utilized around the world, and underground mining is often dangerous. Therefore, many underground mines have established networks that manage and acquire information from sensor nodes deployed on miners and in other places. Since the power supplies of many mobile sensor nodes are batteries, green communication is an effective approach of reducing the energy consumption of a network and extending its longevity. To reduce the energy consumption of networks, all factors that negatively influence the lifetime should be considered. The degree constraint minimum spanning tree (DCMST) is introduced in this study to consider all the heterogeneous factors and assign weights for the next step of the evaluation. Then, a genetic algorithm (GA) is introduced to cluster sensor nodes in the network and balance energy consumption according to several heterogeneous factors and routing paths from DCMST. Based on a comparison of the simulation results, the optimization routing algorithm proposed in this study for use in green communication in underground mines can effectively reduce the network energy consumption and extend the lifetimes of networks.
Non-contact vital signs detection demonstrates significant potential in fields like fire rescue, intelligent healthcare, and smart homes. However, existing methods encounter challenges in extracting accurate signals in noisy and low signal-to-noise ratio (SNR) indoor scenarios and exhibit heavy reliance on empirical parameter tuning. This study proposes a multi-stage optimized method for extracting heart and respiratory signals from Ultra-wideband (UWB) radar by integrating the autocorrelation function (AF), whale optimization algorithm (WOA), and variational mode decomposition (VMD). First, direct current (DC) removal, singular value decomposition (SVD), and Butterworth filtering are applied to suppress noise and eliminate baseline drift. Then, autocorrelation analysis of the slow-time radar signal is used to leverage the periodicity of vital signs for accurate target distance detection, improving signal extraction accuracy. Finally, WOA dynamically optimizes VMD parameters to adapt to time-varying signals, enhance mode separation and noise resistance, and screen effective components based on modal energy contribution. Vital signs frequencies are subsequently extracted using Fast Fourier transform (FFT). Experiments using 180 datasets from three volunteers at four distances (0.8 m–2.4 m) show that the proposed method achieves average errors of 4.84% in distance, 2.52% in respiratory rate (RR) and 3.54% in heart rate (HR) under static indoor line-of-sight conditions. These results indicate that the method proposed in this paper can provide accurate and relatively stable non-contact vital signs estimation within the test distance range.
11 September 2026 in Optics and Lasers in Engineering