Reza Masoudnia

Dr. Reza Masoudnia


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in Journal of Structural Engineering
Verified
Journal Article
Closed access
AHAshkan Hashemi
Ashkan Hashemi
PZPouyan Zarnani
Pouyan Zarnani
RMReza Masoudnia
Reza Masoudnia
PQPierre Quenneville
Pierre Quenneville
Allowing a wall to rock and uplift during a seismic event can cap the forces and minimize the postevent residual damage. Slip friction connections comprised of flat steel plates sliding over each other have been experimentally tested as the hold-down connectors in timber shear walls and performed well in terms of the hysteretic behavior and the energy dissipation rate. However, the main disadvantage of these joints is the undesirable residual displacements. In recognition of this fact, a novel type of friction joint called a resilient slip friction (RSF) joint is proposed. The innovative configuration of this joint provides the energy dissipation and self-centering behavior all in one compact package. This paper describes the large-scale experimental test conducted on a rocking cross-laminated timber (CLT) wall with RSF joints as the hold-down connectors. Additionally, a series of capacity equations are presented and validated by comparing the analytical results with the experimental data. The results confirmed that this technology has the potential to provide a robust solution for seismic-resilient structures.

1 July 2018 in Journal of Structural Engineering
Verified
Journal Article
Closed access
RMReza Masoudnia
Reza Masoudnia
AHAshkan Hashemi
Ashkan Hashemi
PQPierre Quenneville
Pierre Quenneville
A timber composite beam consists of a cross-laminated timber (CLT) panel attached to a girder such as a laminated veneer lumber (LVL) beam. Under positive bending moment, part of the CLT panel acts as the flange of the LVL girder and resists compression. When the spacing between LVL girders becomes large, simple beam theory is not applicable because the compressive stresses in the flange vary with the distance from the LVL girder web, and the flange area over the web is more highly stressed than the extremities. This phenomenon is termed shear lag. For the design of steel-concrete composite sections, the effective flange width concept has been introduced into national and international design specifications. Despite the large number of studies regarding steel and concrete composite structures, comparative, comprehensive research has not been conducted on timber composite structures. In this study, a numerical model is developed and experimentally validated for analyzing different configurations of timber composite beams. Based on a parametric study, a formula is proposed for determining the effective flange width of timber composite beams.

1 March 2021 in Advances in Structural Engineering
Verified
Journal Article
Closed access
PDF file
RMReza Masoudnia
Reza Masoudnia
Stub girder flooring systems are a widely used system in modern steel buildings. This type of system is a composite flooring system consisting of a continuous steel beam and a reinforced concrete slab set apart by a series of short, and usually wide, flange parts known as stubs. While many studies and research have been conducted on this system in steel-concrete composite structures, comparable comprehensive research has not been done on Stub girder flooring system for timber construction. This study represents a review on stub girders, and focuses on experimental and analytical works in the area. Finally, pervious researches and experimental data about stub girder flooring system have been collected and summarized in a table format which has been listed parameters in the researches.

6 January 2026 in Buildings
Verified
Journal Article
Open access
PDF file
RMReza Masoudnia
Reza Masoudnia
Zhiyuan FangZhiyuan Fang
Zhiyuan Fang
AHAshkan Hashemi
Ashkan Hashemi
SMSaber Masoudnia
Saber Masoudnia
James B.P. LimJames B.P. Lim
James B.P. Lim
This paper proposes the use of cross-laminated timber (CLT) panels in conjunction with back-to-back cold-formed steel (CFS) channel or angle sections in combination with laminated veneer lumber (LVL) beam, for composite CFS-timber beams. Under a hogging and sagging moment, part of the CLT panel will act compositely with CFS-LVL in order to resist compression, while the lower part of CFS-LVL web will be in tension. Whilst shear lag effects have been well-researched for concrete-steel composite beams, there has been little research on this for CLT panels working with CFS-LVL sections. In this paper, the finite element method (FEM) is used to determine the effective flange width (FFW) for CFS-timber beams. In conclusion, the obtained result has shown that the EFW increases with any changes that lead to an increase in the ratio of the transverse layer’s depth to the longitudinal layer’s depth. Moreover, combinations of CFS sections with LVL have significantly resulted in the depth-of-beam decrease.