Annachiara Strazza

Dr. Annachiara Strazza


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Gait & Posture
Verified
Journal Article
Closed access
ASAnnachiara Strazza
Annachiara Strazza
Alessandro MengarelliAlessandro Mengarelli
Alessandro Mengarelli
Sandro FiorettiSandro Fioretti
Sandro Fioretti
Laura BurattiniLaura Burattini
Laura Burattini
Valentina AgostiniValentina Agostini
Valentina Agostini
Francesco Di NardoFrancesco Di Nardo
Francesco Di Nardo

27 December 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SCStefano Cardarelli
Stefano Cardarelli
Alessandro MengarelliAlessandro Mengarelli
Alessandro Mengarelli
Andrea TigriniAndrea Tigrini
Andrea Tigrini
ASAnnachiara Strazza
Annachiara Strazza
Francesco Di NardoFrancesco Di Nardo
Francesco Di Nardo
Federica VerdiniFederica Verdini
Federica Verdini
In this paper, a self-contained procedure to estimate the vertical, medial-lateral, and anterior-posterior displacement of a single sacrum-worn inertial measurement unit (IMU) is presented, which can be related to the human body center of mass (CoM) displacement during treadmill walking through an adaptation of the sacral marker method. Further, a magnetometer-free custom sensor-fusion algorithm for orientation estimation is proposed alongside a practical alignment procedure to refer relative IMU orientation estimation to a ground-fixed reference frame. Twelve healthy subjects performed two trials of treadmill walking at 3, 4 and 5 km/h for 150 s, with a sacrum-worn IMU. Orientation and displacement estimations were then compared with those obtained from an optoelectronic measurement system. Roll, pitch and yaw angles showed root mean square errors (RMSE) lower than 2 deg for walking trials at 3, 4 and 5 km/h, with Pearson’s correlation coefficient higher than 0.90 for each angle. Displacement accuracy was evaluated in terms of peak-to-trough distances and RMSE. Mean errors resulted lower than 1 mm for each axis of interest and for each gait speed, with RMSE not higher than 2.5 mm. The proposed off-line algorithm can be used in low-budget and infrastructure-free environments, to achieve reliable CoM displacement estimation during cyclic activities such as treadmill walking.

4 June 2018 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
Alessandro MengarelliAlessandro Mengarelli
Alessandro Mengarelli
SCStefano Cardarelli
Stefano Cardarelli
ASAnnachiara Strazza
Annachiara Strazza
Francesco Di NardoFrancesco Di Nardo
Francesco Di Nardo
SFSandro Fioretti
Sandro Fioretti
Federica VerdiniFederica Verdini
Federica Verdini
The functional reach test (FRT) is widely used for assessing dynamic balance stability in elderly and pathological subjects. Force platforms (FP) represent a fundamental part of the instrumented FRT experimental setup, due to the central role of center-of-pressure (COP) displacement in FRT analysis. Recently, the Nintendo Wii Balance Board (NBB) has been suggested as a low-cost and reliable device for ground reaction force and COP measurement in poorly dynamic motor tasks. Therefore, this study aimed to compare NBB-COP data with those obtained from a laboratory-grade platform during FRT. Data from forty-eight healthy subjects were simultaneously acquired from both devices. FP- and NBB-COP trajectories showed a remarkable correlation in both directions (r>0.990) and low root-mean-square error values (1.14±0.88 mm and 0.55±0.28 mm for anterior-posterior and medial-lateral direction). Fixed biases between COP-based parameters did not exceed 2% of the FP outcomes, with high consistency throughout the present measurement range (ICC consistency always >0.950). Only the COP mean-velocity exhibited a tendency towards proportional errors, which can be adjusted by a calibration of NBB data. Findings of this study confirmed the NBB validity for COP measurement in a widely used motor task as the functional reach, supporting the feasibility of NBB in research scenarios.

27 June 2019 in Biosensors
Verified
Journal Article
Open access
PDF file
Francesco Di NardoFrancesco Di Nardo
Francesco Di Nardo
ASAnnachiara Strazza
Annachiara Strazza
Alessandro MengarelliAlessandro Mengarelli
Alessandro Mengarelli
SCStefano Cardarelli
Stefano Cardarelli
Andrea TigriniAndrea Tigrini
Andrea Tigrini
Sandro FiorettiSandro Fioretti
Sandro Fioretti
Hemiplegia is a neurological disorder that is often detected in children with cerebral palsy. Although many studies have investigated muscular activity in hemiplegic legs, few EMG-based findings focused on unaffected limb. This study aimed to quantify the asymmetric behavior of lower-limb-muscle recruitment during walking in mild-hemiplegic children from surface-EMG and foot-floor contact features. sEMG signals from tibialis anterior (TA) and gastrocnemius lateralis and foot-floor contact data during walking were analyzed in 16 hemiplegic children classified as W1 according to Winter’ scale, and in 100 control children. Statistical gait analysis, a methodology achieving a statistical characterization of gait by averaging surface-EMG-based features, was performed. Results, achieved in hundreds of strides for each child, indicated that in the hemiplegic side with respect to the non-hemiplegic side, W1 children showed a statistically significant: decreased number of strides with normal foot-floor contact; decreased stance-phase length and initial-contact sub-phase; curtailed, less frequent TA activity in terminal swing and a lack of TA activity at heel-strike. The acknowledged impairment of anti-phase eccentric control of dorsiflexors was confirmed in the hemiplegic side, but not in the contralateral side. However, a modified foot-floor contact pattern is evinced also in the contralateral side, probably to make up for balance requirements.

30 June 2017 in Journal of Electromyography and Kinesiology
Verified
Journal Article
Closed access
Francesco Di NardoFrancesco Di Nardo
Francesco Di Nardo
Alessandro MengarelliAlessandro Mengarelli
Alessandro Mengarelli
ASAnnachiara Strazza
Annachiara Strazza
Valentina AgostiniValentina Agostini
Valentina Agostini
MKMarco KNAFLITZ
Marco KNAFLITZ
Sandro FiorettiSandro Fioretti
Sandro Fioretti

28 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Francesco Di NardoFrancesco Di Nardo
Francesco Di Nardo
Martina MoranoMartina Morano
Martina Morano
ASAnnachiara Strazza
Annachiara Strazza
Sandro FiorettiSandro Fioretti
Sandro Fioretti
Background: Muscle co-contraction plays a significant role in motion control. Available detection methods typically only provide information in the time domain. The current investigation proposed a novel approach for muscle co-contraction detection in the time–frequency domain, based on continuous wavelet transform (CWT). Methods: In the current study, the CWT-based cross-energy localization of two surface electromyographic (sEMG) signals in the time–frequency domain, i.e., the CWT coscalogram, was adopted for the first time to characterize muscular co-contraction activity. A CWT-based denoising procedure was applied for removing noise from the sEMG signals. Algorithm performances were checked on synthetic and real sEMG signals, stratified for signal-to-noise ratio (SNR), and then validated against an approach based on the acknowledged double-threshold statistical algorithm (DT). Results: The CWT approach provided an accurate prediction of co-contraction timing in simulated and real datasets, minimally affected by SNR variability. The novel contribution consisted of providing the frequency values of each muscle co-contraction detected in the time domain, allowing us to reveal a wide variability in the frequency content between subjects and within stride. Conclusions: The CWT approach represents a relevant improvement over state-of-the-art approaches that provide only a numerical co-contraction index or, at best, dynamic information in the time domain. The robustness of the methodology and the physiological reliability of the experimental results support the suitability of this approach for clinical applications.