Jumpei Saito

Dr. Jumpei Saito

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 May 2026 in Journal of Arrhythmia
Verified
Journal Article
Open access
PDF file
KSKoji Sudo
Koji Sudo
KKKenji Kuroki
Kenji Kuroki
TATetsuya Asakawa
Tetsuya Asakawa
KNKazuya Nakagawa
Kazuya Nakagawa
JSJumpei Saito
Jumpei Saito
ASAkira Sato
Akira Sato
Introduction: AutoMark Index (AI) is a novel ablation algorithm integrating contact force (CF), radiofrequency (RF) current, and application duration to provide real‐time lesion formation feedback. Data of AI using a flexible‐tip RF ablation catheter for cavotricuspid isthmus (CTI) ablation remain limited. The objective was to evaluate the efficacy and safety of AI‐guided CTI ablation. Methods: Consecutive 148 patients undergoing CTI ablation with a CF‐sensing flexible‐tip ablation catheter were included. Outcomes using an AI‐guided protocol (50 W, targeting AI of 50; AI‐50 group, 62 patients) were compared with a conventional protocol (40 W for 20 s; 40‐W group, 86 patients). Results: The first‐line success rate showed no difference between the two groups (40‐W group: 72/86 [84.7%] vs. AI‐50 group: 51/62 [82.2%], p = 0.81). The total RF application showed no difference (40‐W group: 12 [9.5–15] vs. AI‐50 group: 12 [9.7–16], p = 0.50); however, significant differences were observed in the total RF duration (40‐W group: 274 [211–372] s vs. AI‐50 group: 180 [138–249] s, p < 0.001), the RF duration for initial block (40‐W group: 225 [163–323] s vs. AI‐50 group: 149 [109–221] s, p < 0.001), and CTI procedural time (40‐W group: 9.2 [6.0–14.6] min vs. AI‐50 group: 6.3 [4.5–9.7] min, p = 0.007). No significant differences were observed in the mean CF, average temperature, and CTI length between the two groups. No major complications were observed in either of the groups. Conclusion: AI‐guided CTI ablation protocol is efficient in shortening RF duration for acute bidirectional CTI block and CTI procedure time compared to the conventional 40 W ablation protocol.

22 October 2024 in Pacing and Clinical Electrophysiology
Verified
Journal Article
Closed access
JSJumpei Saito
Jumpei Saito
KDKato Daiki
Kato Daiki
SHSato Hirotoshi
Sato Hirotoshi
TMToshihiko Matsuda
Toshihiko Matsuda
YKYui Koyanagi
Yui Koyanagi
MOMasahiko Ochiai
Masahiko Ochiai

1 January 2024 in medRxiv
Verified
Preprint
Open access
PDF file
SNShuro Narui
Shuro Narui
MYMyong Hwa Yamamoto
Myong Hwa Yamamoto
HMHiroyoshi Mori
Hiroyoshi Mori
KAKisaki Amemiya
Kisaki Amemiya
TOToshitaka Okabe
Toshitaka Okabe
MOMasahiko Ochiai
Masahiko Ochiai
Background Percutaneous coronary intervention (PCI) for lesions with calcified nodules (CNs) is associated with worse outcomes than PCI for other calcified lesions. We aimed to clarify the relationship between CNs at index PCI, optical coherence tomography (OCT) findings at 8-month follow-up, and clinical outcomes using serial OCT. Methods This retrospective observational study utilized data from a prospective, single-center registry. We conducted consecutive PCI for calcified lesions requiring rotational atherectomy (RA) with OCT guidance. We categorized 51 patients (54 lesions) into those with (16 patients [16 lesions]) and without CNs (35 patients [38 lesions]). Results Post-PCI, stent expansion was comparable between the two groups, and CN-like protrusion was observed in 75% of patients in the CN group. Follow-up OCT at 8 months revealed in-stent CNs in 54% of treated CN lesions with CN-like protrusion, whereas non-CN lesions lacked in-stent CNs. The CN group exhibited greater maximum neointimal tissue (NIT) thickness than the non-CN group (p180°. Conclusions Following RA treatment with acceptable stent expansion, the presence of CNs before PCI correlated with greater neointimal tissue formation with in-stent CNs, resulting in a higher TLR rate, especially in lesions with maximum CN angles exceeding 180°. What is Known Calcified lesions with calcified nodules (CNs) are associated with a higher target lesion revascularization (TLR) rate in percutaneous coronary intervention (PCI) than other types of calcified lesions. In-stent CNs may appear after PCI for CNs and is a major cause of increased TLR rates after PCI for CNs. The relationship between calcified plaque morphology at the index PCI, neointimal tissue characteristics concerning in-stent CN location and frequency during follow-up, and subsequent clinical outcomes has not been explored with serial optical coherence tomography. What the Study Adds Follow-up OCT at 8 months revealed in-stent CNs in 54% of treated CN lesions with CN-like protrusion, whereas non-CN lesions lacked in-stent CNs. PCI for CNs exhibited a higher clinically-driven target lesion revascularization rate than PCI for lesions without CNs, primarily in lesions with maximum CN angles >180°.

29 December 2024 in medRxiv
Verified
Preprint
Open access
PDF file
JSJumpei Saito
Jumpei Saito
KDKato Daiki
Kato Daiki
SHSato Hirotoshi
Sato Hirotoshi
TMToshihiko Matsuda
Toshihiko Matsuda
YKYui Koyanagi
Yui Koyanagi
MOMasahiko Ochiai
Masahiko Ochiai
Background In adult patients with systolic heart failure, the presence of adjacent, nonoverlapping E and A waves on Doppler echocardiography is associated with optimal cardiac output and favorable clinical outcomes. However, the clinical significance of echocardiographic overlap in patients with atrial fibrillation (AF) remains uncertain. This study aimed to explore the relationship between E-wave and A-wave overlap, assessed the day after catheter ablation, and the recurrence of atrial arrhythmias (AR) following AF ablation. Methods Patients with AF who underwent first-time arrhythmia ablation were included in this study. Transthoracic echocardiography was performed on the day following catheter ablation to evaluate the presence of E- and A-wave overlap. The relationship between overlap length and recurrence of AR after AF ablation was analyzed. Results The study included 175 patients (124 males; mean age: 68 years [range 52–79]; mean CHA2DS2-Vasc score: 2 [range 0–4]; and 93 with paroxysmal AF) who underwent AF ablation. There were no significant differences between the two groups in terms of heart failure history or echocardiographic parameters prior to catheter ablation. However, the absolute overlap length was significantly prolonged in the AR group (59 ms [range 9–160] vs. 120 ms [range 28.6–226]; P < .001). Furthermore, the rate of AR was significantly lower in the group without prolonged overlap length (HR, 0.15 [95% CI, 0.07–0.30]; P < .001). These findings were consistent across all AF types. Conclusions The length of E-wave and A-wave overlap appears to be a significant predictor of AR following AF ablation.

18 September 2026 in Heart Rhythm O2
Verified
Journal Article
Open access
JSJumpei Saito
Jumpei Saito
KKKenji Kuroki
Kenji Kuroki
TGTakeaki Goto
Takeaki Goto
CAChisa Asahina
Chisa Asahina
KSKoji Sudo
Koji Sudo
ASAkira Sato
Akira Sato

4 March 2025 in medRxiv
Verified
Preprint
Open access
PDF file
JSJumpei Saito
Jumpei Saito
KDKato Daiki
Kato Daiki
SHSato Hirotoshi
Sato Hirotoshi
TMToshihiko Matsuda
Toshihiko Matsuda
YKYui Koyanagi
Yui Koyanagi
MOMasahiko Ochiai
Masahiko Ochiai
Background: Multielectrode mapping catheters, such as the OCTARAY and OPTRELL, are essential in creating myocardial electroanatomical mapping in arrhythmias. The OCTARAY is a multi-spline mapping catheter with 48 closely spaced multielectrodes that enables high-resolution electroanatomical mapping, while the OPTRELL is a multi-electrode catheter with 36 electrodes arranged on eight radiating splines. However, only a few studies have compared their performance. In this study, we aimed to compare the OCTARAY and OPTRELL catheters in two areas: left atrial (LA) mapping during atrial fibrillation (AF) ablation; and premature ventricular contraction (PVC) mapping. Methods: Twenty patients (Ten patients for LA mapping and ten for PVC mapping) were enrolled. LA voltage mapping was performed twice, alternating between catheters post-AF ablation. Parameters compared included mapping time, mapping points, catheter-induced premature atrial contraction (PACs), tissue proximity indication, low voltage area, and fluoroscopy time. For PVC mapping, comparisons included mapping time, catheter-induced PVCs, earliest activation time measured from the onset of PVC QRS, earliest activation point, and fluoroscopy time. Results: Compared with THE OCTARAY, mean voltage using the OPTRELL was higher (0.192 mV[0.072, 0.48] vs. 0.126 mV[0.042, 0.378]; P = .001) and the percentage of tissue proximity indication positive was also higher (14.97% vs. 11.45%; P < .001). However, there were no significant differences in low voltage area between the two groups (39.5 m 2 [16.5, 66.8] vs. 40[23.6, 61]; P = .861), and in other LA parameters. In PVC mapping, catheter-induced PVCs using OPTRELL were significantly fewer than the OCTARAY (100 [32, 337] vs. 247 [110, 745], P = .039), with fewer catheter induced PVCs per minute (15 [6, 23] vs. 35 [20, 71], P = .039). However, no significant differences were observed in other PVCs mapping parameters. Conclusion: The OPTRELL catheter demonstrated higher voltage recordings in LA mapping and fewer catheter-induced PVCs compared with the OCTARAY catheter. However, no significant difference was observed in other mapping parameters.