Nick Houston

Nick Houston

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 March 2021 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
ABAagaman Bhusal
Aagaman Bhusal
NHNick Houston
Nick Houston
TLTianjun Li
Tianjun Li
We explore a novel detection possibility for solar axions, which relies only on their couplings to nucleons, via the axion-induced dissociation of deuterons into their constituent neutrons and protons. An opportune target for this process is the now-concluded Sudbury Neutrino Observatory (SNO) experiment, which relied upon large quantities of heavy water to resolve the solar neutrino problem. From the full SNO dataset we exclude in a model-independent fashion isovector axion-nucleon couplings |gaN3|≡12|gan−gap|>2×10−5  GeV−1 at 95% C.L. for sub-MeV axion masses, covering previously unexplored regions of the axion parameter space. In the absence of a precise cancellation between gan and gap this result also exceeds comparable constraints from other laboratory experiments, and excludes regions of the parameter space for which astrophysical constraints from SN1987A and neutron star cooling are inapplicable due to axion trapping.

27 October 2023 in Physical Review D
Verified
Journal Article
Open access
PDF file
XZXin Zhang
Xin Zhang
NHNick Houston
Nick Houston
Tianjun LiTianjun Li
Tianjun Li
A number of nuclear decay anomalies have been reported in the literature, which purport to show periodic variations in the decay rates of certain radioisotopes. If these reports reflect reality, they would necessitate a seismic shift in our understanding of fundamental physics. We provide the first mechanism to explain these findings, via the misalignment mechanism of QCD axion dark matter, wherein oscillations of the effective θ angle induce periodic variation in nuclear binding energies and hence decay rates. As we expect this effect to be most pronounced in low-Q systems, we analyze 12 years of tritium decay data (Q≃18.6  keV) taken at the European Commission’s Joint Research Centre. Finding no statistically significant excess, we exclude axion decay constants below 9.4×1012–1.8×1010  GeV (95% confidence level) for masses in the 1.7×10−23–8.7×10−21  eV range.

22 March 2021 in International Journal of Modern Physics D
Verified
Journal Article
Closed access
PDF file
CLChuang Li
Chuang Li
NHNick Houston
Nick Houston
TLTianjun Li
Tianjun Li
QYQiaoli Yang
Qiaoli Yang
XZXin Zhang
Xin Zhang

16 July 2024 in Physical Review D
Verified
Journal Article
Open access
PDF file
DHDong He
Dong He
JFJie Fan
Jie Fan
XGXin Gao
Xin Gao
YGYu Gao
Yu Gao
NHNick Houston
Nick Houston
ACAPEX Collaboration
APEX Collaboration
The dark photon is a promising candidate for the dark matter which comprises most of the matter in our visible Universe. Via kinetic mixing with the Standard Model it can also be resonantly converted to photons in an electromagnetic cavity, offering novel experimental possibilities for the discovery and study of dark matter. We report the results of a pathfinder dark photon dark matter cavity search experiment performed at Hunan Normal University and the Institute of Physics, Chinese Academy of Sciences, representing the first stage of the Axion and dark Photon EXperiment program. Finding no statistically significant excess, we place an upper limit on the kinetic mixing parameter |χ|<3.7×10−13 around mA≃29.5  μeV at 90% confidence level. This result exceeds other constraints on dark photon dark matter in this frequency range by roughly an order of magnitude.

16 June 2025 in Research in Astronomy and Astrophysics
Verified
Journal Article
Closed access
MEMengtian梦甜Li李
Mengtian梦甜Li李
HAHao昊Chen陈
Hao昊Chen陈
WGWen-Qing Guo
Wen-Qing Guo
YCYogesh Chandola
Yogesh Chandola
BDBohao Duan
Bohao Duan
NHNick Houston
Nick Houston
The axion, a leading dark matter (DM) candidate, can convert to photons in neutron star (NS) magnetospheres via the Primakoff effect, producing narrow-band radio emission that may be detected with high-sensitivity radio telescopes. Previous studies searched for axion DM-induced signals from the isolated NS J0806.4-4123 using observations of the MeerKAT UHF band (544–1088 MHz), but excluded the 1051–1088 MHz subband to mitigate potential sideband contamination. To probe this unexplored parameter space, we reprocessed the 1000–1088 MHz subband data using optimized radio frequency interference (RFI) flagging and meticulous sideband calibration. The flux stability of the calibrators and the consistency with MeerKAT’s system equivalent flux density confirmed the reliability of the data within the 1000–1080 MHz range, while the 1080–1088 MHz subband was omitted due to flux anomalies. No significant signals exceeding 5σ significance were detected within the axion mass range of 4.136–4.467 μeV (1000–1080 MHz), including the previously unprobed range 4.347–4.467 μeV (1051–1080 MHz). Our null detection sets new stringent constraints with MeerKAT NS data, excluding axion-photon couplings ∣g aγγ ∣ ≳ 8.2 × 10−12 GeV−1 at the 95% confidence level for DM masses between 4.347 and 4.467 μeV.

27 March 2026 in Physical Review Research
Verified
Journal Article
Open access
YLYu-Ang Liu
Yu-Ang Liu
BABilal Ahmad
Bilal Ahmad
NHNick Houston
Nick Houston
The axion is a particularly well-motivated candidate for the dark matter comprising most of the mass of our visible Universe, leading to worldwide experimental and observational efforts toward its discovery. As is well known, resonant cavities are a primary tool in this search, where they are used to enhance the conversion rate of axions into photons in a background electromagnetic field. What is perhaps less well appreciated is that resonant cavities can also enhance the rate at which axions decay to two photons, a manifestation of the Purcell effect. We examine this possibility and show that it offers a previously unexplored method to search the axion parameter space in a way that is competitive and complementary to other approaches, with the capability to probe a well-motivated region for QCD axion dark matter. Furthermore, we establish that this method can be implemented via preexisting axion heterodyne detection schemes, enabling such experiments to perform these searches with minimal modification.