Objective: The goal of this study was to use highly accurate nonrigid algorithms to locate the position of cochlear implant (CI) electrodes and correlate this with audiological performance. Patients: After obtaining institutional review board approval, adult patients who had bilateral CIs were identified, and those with preoperative temporal bone computed tomographic scans were asked to return for a postintervention computed tomography. Sixteen adult patients agreed. Demographics, cause of deafness, length of auditory deprivation, and audiological performance were recorded. Intervention: Using a nonrigid model of the shape variations of intracochlear anatomy, the location of the basilar membrane was specified in relationship to the electrode array. The number of electrodes within each compartment of the cochlea was correlated with hearing in noise and consonant-noun-consonant scores for the known confounding variable: length of deafness. Main Outcomes: Mann-Whitney U tests of differences were used to compare the hearing performance resulting from implants completely in the scala tympani (ST) versus those not completely in the ST. Results: Of all implants, 62.5% were fully inserted in the ST; 34.4% were partially inserted into the ST and 3.1% was fully inserted in the scala vestibuli. Controlling for the known contributing variable of length of auditory deprivation, our results show that the location of electrodes in relationship to the scala is not predictive of audiological performance. Conclusion: We have assessed electrode placement and correlated it with audiological outcome. The presence of the electrodes solely in the ST was not predictive of outcome. We estimate that it would take analyzing data of thousands of CI patients before any valid correlations can be made.
Introduction The Maternal Infant Health Outreach Worker (MIHOW) program is a home visiting program, utilizing peer mentors to improve maternal/child health outcomes in underserved communities. Findings are presented from a randomized clinical trial (RCT) testing the efficacy of the MIHOW model in a sample of Hispanic women in Tennessee. We hypothesized maternal and infant outcomes would be better in women assigned to MIHOW than women assigned to the minimal education intervention (MEI) group (receipt of educational materials). Methods Women entered the study during pregnancy (< 26 weeks gestation) and were followed through 6 months postpartum. A total of 188 women were enrolled and randomly assigned (MEI = 94; MIHOW = 94), with 178 women completing the study (MEI = 87; MIHOW = 91). Results Positive and statistically significant (p < 0.01) effects of MIHOW were observed on breastfeeding self-efficacy and exclusivity, levels of depressive symptoms and parenting stress, safe sleep practices, and infant stimulation in the home. No statistically significant differences were noted in number of prenatal visits. Discussion Results expand limited empiric evidence and provide strong support of the effectiveness of MIHOW on improving health outcomes in this sample of Hispanic mothers and their infants. MIHOW is a viable option for providing culturally sensitive services to immigrant and underserved families.
Reducing dietary energy density has proven to be an effective strategy to reduce energy intakes and promote weight control. This effect appears most robust when a low energy dense preload is consumed before meals. Yet, much discussion continues regarding the optimal form of a preload. The purpose of the present study was to compare effects of a solid (grapefruit), liquid (grapefruit juice) and water preload consumed prior to breakfast, lunch and dinner in the context of caloric restriction.
Objective: Robotic cochlear implant electrode array insertion offers substantial potential advantages, namely repeatability and minimization of insertion forces, leading to decreased intracochlear trauma. Using such a robotic insertion tool, we sought to analyze force profiles during deployment of stylet-containing electrode arrays using either traditional insertion, in which the stylet is withdrawn after complete insertion of the electrode, or Advance Off-Stylet (AOS) insertion, in which the stylet is withdrawn simultaneous with electrode array insertion. Study Design: Prospective. Setting: Tertiary referral center. Interventions: A robotic cochlear implant insertion tool coupled with a force-sensing carriage was used to perform electrode array insertions into an anatomically correct, three-dimensional scala tympani model during either straight insertion (n = 4) or AOS insertion (n = 4). Main Outcome Measures: Both insertion techniques begin with a 7-mm straight insertion during which forces were similar averaging approximately 0.006 N. For insertion from 7 to 17 mm, traditional insertion forces averaged 0.046 ± 0.027 N, with a peak of 0.093 N, and AOS insertion forces averaged 0.008 ± 0.006 N, with a peak of 0.034 N. Beyond 9.74 mm, the difference between traditional and AOS insertion forces was highly significant. Conclusion: With the use of a robotic insertion tool, which minimizes operator variability and maximizes repeatability, we have shown that cochlear implant electrode insertion via AOS is associated with lower average and maximum insertion forces compared with traditional insertion. These findings support the use of AOS over traditional, straight insertion.
Neuroimaging studies in younger adults have demonstrated sex differences in brain processing of painful experimental stimuli. Such differences may contribute to findings that women suffer disproportionately from pain. It is not known whether sex-related differences in pain processing extend to older adults. This cross-sectional study investigated sex differences in pain reports and brain response to pain in 12 cognitively healthy older female adults and 12 cognitively healthy age-matched older male adults (age range 65–81, median = 67). Participants underwent psychophysical assessments of thermal pain responses, functional MRI, and psychosocial assessment. When compared to older males, older females reported experiencing mild and moderate pain at lower stimulus intensities (i.e., exhibited greater pain sensitivity; Cohen’s d = 0.92 and 0.99, respectively, p < 0.01) yet did not report greater pain-associated unpleasantness. Imaging results indicated that, despite the lower stimulus intensities required to elicit mild pain detection in females, they exhibited less deactivations than males in regions associated with the default mode network (DMN) and in regions associated with pain affect (bilateral dorsolateral prefrontal cortex, somatomotor area, rostral anterior cingulate cortex (rACC), and dorsal ACC). Conversely, at moderate pain detection levels, males exhibited greater activation than females in several ipsilateral regions typically associated with pain sensation (e.g., primary (SI) and secondary somatosensory cortices (SII) and posterior insula). Sex differences were found in the association of brain activation in the left rACC with pain unpleasantness. In the combined sample of males and females, brain activation in the right secondary somatosensory cortex was associated with pain unpleasantness. Cognitively healthy older adults in the sixth and seventh decades of life exhibit similar sex differences in pain sensitivity compared to those reported in younger individuals. However, older females did not find pain to be more unpleasant. Notably, increased sensitivity to mild pain in older females was reflected via less brain deactivation in regions associated with both the DMN and in pain affect. Current findings elevate the rACC as a key region associated with sex differences in reports of pain unpleasantness and brain deactivation in older adults. Also, pain affect may be encoded in SII in both older males and females.