CHIA-MING CHANG

Mr. CHIA-MING CHANG

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 June 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
WLWei-Ti Lin
Wei-Ti Lin
CCCHIA-MING CHANG
CHIA-MING CHANG
YHYen-Chih Huang
Yen-Chih Huang
CWChi-Chen Wu
Chi-Chen Wu
Cheng-Chien KuoCheng-Chien Kuo
Cheng-Chien Kuo
Currently, fault identification in most photovoltaic systems primarily relies on experienced engineers conducting on-site tests or interpreting data. However, due to limited human resources, it is challenging to meet the vast demands of the solar photovoltaic market. Therefore, we propose to identify fault types through the current–voltage curves of solar arrays, obtaining curves for various conditions (normal, aging faults, shading faults, degradation faults due to potential differences, short-circuit faults, hot-spot faults, and crack faults) as training data for the model. We employ a multi-input model architecture that combines convolutional neural networks with deep neural networks, allowing both the imagery and feature values of the current–voltage curves to be used as input data for fault identification. This study demonstrates that by inputting the current–voltage curves, irradiance, and module specifications of solar string arrays into the trained model, faults can be identified quickly using actual field data.

25 December 2024 in IEEE Access
Verified
Journal Article
Open access
CCCHIA-MING CHANG
CHIA-MING CHANG
HCHong-Chan Chang
Hong-Chan Chang
CHChun-Chun Hung
Chun-Chun Hung
Cheng-Chien KuoCheng-Chien Kuo
Cheng-Chien Kuo
The large-scale development of battery energy storage systems (BESS) has enhanced grid flexibility in power systems. From the perspective of power system planners, it is essential to consider the reliability of BESS to ensure stable grid operation amid a high reliance on renewable energy. Therefore, this paper investigates BESS models and dynamic parameters used in planning future grids from the viewpoint of power planners. By measuring output response data from BESS units of three companies, dynamic responses are converted into WECC second generic model parameters using optimization algorithms, allowing their use in power system analysis software. Subsequently, using Taiwan's actual power system as the simulation background, N-1 simulations are conducted to explore the impact and benefits of BESS parameters when implementing frequency regulation strategies under two different BESS capacity specifications: 2 MW and 10 MW. In the 2 MW scenario, a comparison of the parameters from the three BESS units under frequency regulation strategies shows slight differences in the rise times of their output responses. However, for a 2 MW capacity, the frequency nadir in the power system remains consistently at 58.692 Hz. The simulation results based on the parameters defined in this research demonstrate the importance of using accurately measured and solved parameters in simulations. In the 10 MW scenario, the BESS capacity can offset the generator trip capacity, thereby revealing differences in response time between different parameters, with the frequency nadirs for the solved parameters being 59.755 Hz, 59.773 Hz, and 59.762 Hz, respectively.

8 November 2025 in Journal of Materials Research and Technology
Verified
Journal Article
Open access
Tzu-Sen SuTzu-Sen Su
Tzu-Sen Su
WLWei-Jun Lin
Wei-Jun Lin
YHYen-Chin Huang
Yen-Chin Huang
CCCHIA-MING CHANG
CHIA-MING CHANG
TYTse-I Yeh
Tse-I Yeh
YSYin-Li Su
Yin-Li Su

24 April 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CCCHIA-MING CHANG
CHIA-MING CHANG
YHYU-MIN HSIN
YU-MIN HSIN
Cheng-Chien KuoCheng-Chien Kuo
Cheng-Chien Kuo
This paper proposes a continuous inertia estimation framework for transmission-level power systems with high renewable energy penetration, using a battery energy storage system (BESS) as a controllable small-signal power injection source. The proposed framework integrates BESS-based active power injection, a two-stage signal-smoothing scheme, and a rate-of-change-of-frequency (RoCoF)-based estimation mechanism to enable continuous inertia estimation without relying on major disturbance events. With noise-robust processing and moving-window analysis, the framework can reliably track inertia variations under noisy measurement conditions and diverse operating scenarios. The framework is validated on the IEEE 39-bus system under renewable energy source (RES) penetration levels of 0%, 10%, 20%, and 30%. The estimation error remains within ±3.5% across all scenarios, ranging from 1.26% at 0% RES penetration to 3.43% at 30% penetration. In addition, the estimated inertia closely follows the theoretical decrease from 3.20 s to 2.22 s as RES penetration increases. These results demonstrate the accuracy and robustness of the proposed framework for continuous inertia monitoring in low-inertia power systems with high-RES penetration.