Yen-Chih Huang

Mr. Yen-Chih Huang

National Taiwan University of Science and Technology, Department of Electrical Engineering
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 May 2021 in Electronics
Verified
Journal Article
Open access
PDF file
KFKuo-Hao Fanchiang
Kuo-Hao Fanchiang
YHYen-Chih Huang
Yen-Chih Huang
Cheng-Chien KuoCheng-Chien Kuo
Cheng-Chien Kuo
The safety of electric power networks depends on the health of the transformer. However, once a variety of transformer failure occurs, it will not only reduce the reliability of the power system but also cause major accidents and huge economic losses. Until now, many diagnosis methods have been proposed to monitor the operation of the transformer. Most of these methods cannot be detected and diagnosed online and are prone to noise interference and high maintenance cost that will cause obstacles to the real-time monitoring system of the transformer. This paper presents a full-time online fault monitoring system for cast-resin transformer and proposes an overheating fault diagnosis method based on infrared thermography (IRT) images. First, the normal and fault IRT images of the cast-resin transformer are collected by the proposed thermal camera monitoring system. Next is the model training for the Wasserstein Autoencoder Reconstruction (WAR) model and the Differential Image Classification (DIC) model. The differential image can be acquired by the calculation of pixel-wise absolute difference between real images and regenerated images. Finally, in the test phase, the well-trained WAR and DIC models are connected in series to form a module for fault diagnosis. Compared with the existing deep learning algorithms, the experimental results demonstrate the great advantages of the proposed model, which can obtain the comprehensive performance with lightweight, small storage size, rapid inference time and adequate diagnostic accuracy.

17 November 2020 in Energies
Verified
Journal Article
Open access
PDF file
Teketay Mulu BezaTeketay Mulu Beza
Teketay Mulu Beza
YHYen-Chih Huang
Yen-Chih Huang
Cheng-Chien KuoCheng-Chien Kuo
Cheng-Chien Kuo
The electrical distribution system has experienced a number of important changes due to the integration of distributed and renewable energy resources. Optimal integration of distributed generators (DGs) and distribution network reconfiguration (DNR) of the radial network have significant impacts on the power system. The main aim of this study is to optimize the power loss reduction and DG penetration level increment while keeping the voltage profile improvements with in the permissible limit. To do so, a hybrid of analytical approach and particle swarm optimization (PSO) are proposed. The proposed approach was tested on 33-bus and 69-bus distribution networks, and significant improvements in power loss reduction, DG penetration increment, and voltage profile were achieved. Compared with the base case scenario, power loss was reduced by 89.76% and the DG penetration level was increased by 81.59% in the 69-bus test system. Similarly, a power loss reduction of 82.13% and DG penetration level increment of 80.55% was attained for the 33-bus test system. The simulation results obtained are compared with other methods published in the literature.

21 June 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
WLWei-Ti Lin
Wei-Ti Lin
CCCHIA-MING CHANG
CHIA-MING CHANG
YHYen-Chih Huang
Yen-Chih Huang
CWChi-Chen Wu
Chi-Chen Wu
Cheng-Chien KuoCheng-Chien Kuo
Cheng-Chien Kuo
Currently, fault identification in most photovoltaic systems primarily relies on experienced engineers conducting on-site tests or interpreting data. However, due to limited human resources, it is challenging to meet the vast demands of the solar photovoltaic market. Therefore, we propose to identify fault types through the current–voltage curves of solar arrays, obtaining curves for various conditions (normal, aging faults, shading faults, degradation faults due to potential differences, short-circuit faults, hot-spot faults, and crack faults) as training data for the model. We employ a multi-input model architecture that combines convolutional neural networks with deep neural networks, allowing both the imagery and feature values of the current–voltage curves to be used as input data for fault identification. This study demonstrates that by inputting the current–voltage curves, irradiance, and module specifications of solar string arrays into the trained model, faults can be identified quickly using actual field data.

30 December 2022 in Electronics
Verified
Journal Article
Open access
PDF file
YHYen-Chih Huang
Yen-Chih Huang
WWWei-Bin Wu
Wei-Bin Wu
Cheng-Chien KuoCheng-Chien Kuo
Cheng-Chien Kuo
Inter-turn short-circuit (ITSC) faults do not necessarily produce high temperatures but have special heat distribution and characteristics. Therefore, a new recognition solution for diagnosing faults is proposed, based on the fault overlay method, and the convolutional neural network (CNN) is trained to achieve the automatic identification of infrared images. In this method, through the coverage of layers, the proposed image augmentation method is carried out and simulates the fault data of increasing training. We produce 43 fault traces through the fault overlay method on the three-phase winding of a transformer and use 90 infrared images of transformers in normal operation combined with them to enhance the amount of image data. The fault recognition ability is realized based on CNN model training, including analysis of experimental results of grayscale and color images, and Gaussian noise. In the test of the practical case, a short-circuit test of the 11.4 kV dry-type transformer is carried out, and the ITSC fault is identified when the load is about 15%. The fault characteristic block on this thermal image is 36.3 degrees, which verifies the identification available by this method, and has a certain reference value for the development of infrared image diagnosis technology for power equipment.

2 February 2021 in Electronics
Verified
Journal Article
Open access
PDF file
YHYen-Chih Huang
Yen-Chih Huang
WCWen-Ching Chang
Wen-Ching Chang
HHHsuan Hsu
Hsuan Hsu
Cheng-Chien KuoCheng-Chien Kuo
Cheng-Chien Kuo
The high penetration of distributed generation in distributed energy systems causes the variation of power loss and makes the power grid become more complicated, so this paper takes various types of optimal algorithms into account and simulates the feeder reconfiguration on the IEEE-33 system as well as the Taiwan power system. The simulation verifies linear population size reduction of successful history-based adaptive differential evolution (L-SHADE) and particle swarm optimization (PSO) fitness in different systems and provides the recommended location of distributed energy. The proposed method keeps the voltage bound of 0.95 to 1.03 p.u. of Taiwan regulation. In the IEEE-33 system, we achieved a 52.57% power loss reduction after feeder reconfiguration, and a 70.55% power loss reduction after the distributed generator was implemented and feeder reconfiguration. Under the variation of load demand and power generation of the Taiwan power system, we establish the system models by forecasting one-day load demand. Then, we propose a one-day feeder switch operation strategy by considering the switches’ operation frequency with the reduction of 83.3% manual operation and recommend feeder automation to achieve feeder power loss reduction, voltage profile improvement and get regional power grid resilient configuration.

9 October 2020 in Energies
Verified
Journal Article
Open access
PDF file
EOErica Mendoza Ocampo
Erica Mendoza Ocampo
YHYen-Chih Huang
Yen-Chih Huang
Cheng-Chien KuoCheng-Chien Kuo
Cheng-Chien Kuo
This paper investigates the feasible reserve of diesel generators in day-ahead unit commitment (DAUC) in order to handle the uncertainties of renewable energy sources. Unlike other studies that deal with the ramping of generators, this paper extends the ramp rate consideration further, using dynamic limits for the scheduling of available reserves (feasible reserve) to deal with hidden infeasible reserve issues found in the literature. The unit commitment (UC) problem is solved as a two-stage day-ahead robust scenario-based unit commitment using a metaheuristic new variant of particle swarm optimization (PSO) called partitioned step PSO (PSPSO) that can deal with the dynamic system. The PSPSO was pre-optimized and was able to find the solution for the base-case UC problem in a short time. The evaluation of the optimized UC schedules for different degrees of reserve consideration was analyzed. The results reveal that there is a significant advantage in using the feasible reserve formulation, especially for the deterministic approach, over the conventional computation in dealing with uncertainties in on-the-day operations even with the increase in the reserve schedule.