A DBD plasma is used to generate a multitude of by-products from the degradation of n-hexane molecules. The BTrap and other instruments follow n-hexane and organic by-products mixing ratios, allowing us to identify a large amount of molecules.
10 June 2020 in Journal of the American Society for Mass Spectrometry
Membrane Inlet Mass Spectrometry (MIMS) was used to analyze monochloramine solutions (NH2Cl) and ammonia solutions in a compact FTICR. Chemical ionization enables identification and quantification of the products present in the permeate. The responses of protonated monochloramine and ammonium increase linearly with the solution concentration. The enrichments were respectively 1.2 and 5.5. Pervaporation is dependent on pH and only the basic form of ammonia NH3 pervaporates through the membrane. Unexpectedly, the small ammonia molecule permeated very slowly. It could be due to interactions with water molecules inside the membrane that create clusters. Moreover, NH2Cl solutions, in addition to the NH3Cl+ signal, presented a strong NH4+ signal at m/z 18.034. Ammonia presence in the low-pressure zone before ionization is probable as NH4+ was detected with all the precursors used, particularly CF3+ and trimethylbenzene that presents a proton affinity higher than monochloramine. Ammonia may be formed inside the membrane due to the fact that NH2Cl is unstable and may react with the water present in the membrane. Those results highlight the need for caution when dealing with chloramines in MIMS and more generally with unstable molecules.
7 September 2018 in Journal of Physics D: Applied Physics
The proton transfer reaction mass spectrometry (PTR-MS) is used to follow the toluene concentration at the exit of a dielectric barrier discharge, for an inlet gas mixture of dry air with organic molecules at a concentration in the range 10–100 ppm, at atmospheric pressure and room temperature. The precursor ion is H 3 O + , and toluene is detected at mass 93 u, corresponding to the (C 6 H 5 CH 3 )–H + ion. The PTR-MS is used together with optical absorption spectroscopies to follow ozone and carbon dioxide molecules. Two different discharge regimes are studied: without or with significant self-warming effects. The PTR-MS diagnostic appears as a very useful tool for precise monitoring of the concentration of this organic molecule, and to get real-time information about the energy efficiency for the removal of the pollutant during the discharge operation, as function of the discharge regime.
Membrane Inlet Mass Spectrometry (MIMS) was used to analyze monochloramine solutions (NH2Cl) and ammonia solutions in a compact FTICR. Chemical ionization enables identification and quantification of the products present in the permeate. The responses of protonated monochloramine and ammonium increase linearly with the solution concentration. The enrichments were respectively 1.2 and 5.5. Pervaporation is dependent on pH and only the basic form of ammonia NH3 pervaporates through the membrane. Unexpectedly, the small ammonia molecule permeated very slowly. It could be due to interactions with water molecules inside the membrane that create clusters. Moreover, NH2Cl solutions, in addition to the NH3Cl+ signal, presented a strong NH4+ signal at m/z 18.034 . Ammonia presence in the low-pressure zone before ionization is probable as NH4+ was detected with all the precursors used, particularly CF3+ and trimethylbenzene that presents a proton affinity higher than monochloramine. Ammonia may be formed inside the membrane due to the fact that NH2Cl is unstable and may react with the water present in the membrane. Those results highlight the need for caution when dealing with chloramines in MIMS and more generally with unstable molecules.