Michel Heninger

Dr. Michel Heninger

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 May 2018 in Analytical Chemistry
Verified
Journal Article
Closed access
Michel HeningerMichel Heninger
Michel Heninger
HMHélène Mestdagh
Hélène Mestdagh
ELEssyllt Louarn
Essyllt Louarn
GMGérard Mauclaire
Gérard Mauclaire
PBPierre Boissel
Pierre Boissel
Joël LemaireJoël Lemaire
Joël Lemaire

26 October 2023 in The Analyst
Verified
Journal Article
Open access
PDF file
PTPerla Trad
Perla Trad
NBNicole Blin-Simiand
Nicole Blin-Simiand
PJPascal Jeanney
Pascal Jeanney
SPStéphane Pasquiers
Stéphane Pasquiers
JLJoel Lemaire
Joel Lemaire
Michel HeningerMichel Heninger
Michel Heninger
A DBD plasma is used to generate a multitude of by-products from the degradation of n-hexane molecules. The BTrap and other instruments follow n-hexane and organic by-products mixing ratios, allowing us to identify a large amount of molecules.

10 June 2020 in Journal of the American Society for Mass Spectrometry
Verified
Journal Article
Closed access
STSébastien Thomas
Sébastien Thomas
NBNicole Blin-Simiand
Nicole Blin-Simiand
Michel HeningerMichel Heninger
Michel Heninger
PJPascal Jeanney
Pascal Jeanney
Joël LemaireJoël Lemaire
Joël Lemaire
ELEssyllt Louarn
Essyllt Louarn

3 December 2018 in Sensors
Verified
Journal Article
Open access
PDF file
ELEssyllt Louarn
Essyllt Louarn
AAAbdoul. Monem Asri-Idlibi
Abdoul. Monem Asri-Idlibi
JLJulien Leprovost
Julien Leprovost
Michel HeningerMichel Heninger
Michel Heninger
HMHélène Mestdagh
Hélène Mestdagh
Membrane Inlet Mass Spectrometry (MIMS) was used to analyze monochloramine solutions (NH2Cl) and ammonia solutions in a compact FTICR. Chemical ionization enables identification and quantification of the products present in the permeate. The responses of protonated monochloramine and ammonium increase linearly with the solution concentration. The enrichments were respectively 1.2 and 5.5. Pervaporation is dependent on pH and only the basic form of ammonia NH3 pervaporates through the membrane. Unexpectedly, the small ammonia molecule permeated very slowly. It could be due to interactions with water molecules inside the membrane that create clusters. Moreover, NH2Cl solutions, in addition to the NH3Cl+ signal, presented a strong NH4+ signal at m/z 18.034. Ammonia presence in the low-pressure zone before ionization is probable as NH4+ was detected with all the precursors used, particularly CF3+ and trimethylbenzene that presents a proton affinity higher than monochloramine. Ammonia may be formed inside the membrane due to the fact that NH2Cl is unstable and may react with the water present in the membrane. Those results highlight the need for caution when dealing with chloramines in MIMS and more generally with unstable molecules.

7 September 2018 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
PDF file
SPStéphane Pasquiers
Stéphane Pasquiers
Michel HeningerMichel Heninger
Michel Heninger
NBN Blin-Simiand
N Blin-Simiand
Joël LemaireJoël Lemaire
Joël Lemaire
GBGerard Bauville
Gerard Bauville
HMHélène Mestdagh
Hélène Mestdagh
The proton transfer reaction mass spectrometry (PTR-MS) is used to follow the toluene concentration at the exit of a dielectric barrier discharge, for an inlet gas mixture of dry air with organic molecules at a concentration in the range 10–100 ppm, at atmospheric pressure and room temperature. The precursor ion is H 3 O + , and toluene is detected at mass 93 u, corresponding to the (C 6 H 5 CH 3 )–H + ion. The PTR-MS is used together with optical absorption spectroscopies to follow ozone and carbon dioxide molecules. Two different discharge regimes are studied: without or with significant self-warming effects. The PTR-MS diagnostic appears as a very useful tool for precise monitoring of the concentration of this organic molecule, and to get real-time information about the energy efficiency for the removal of the pollutant during the discharge operation, as function of the discharge regime.

23 October 2018 in Preprints.org
Verified
Preprint
Open access
PDF file
ELEssyllt Louarn
Essyllt Louarn
AAA. Monem Adli-Idlibi
A. Monem Adli-Idlibi
JLJulien Leprovost
Julien Leprovost
Michel HeningerMichel Heninger
Michel Heninger
HMHélène Mestdagh
Hélène Mestdagh
Membrane Inlet Mass Spectrometry (MIMS) was used to analyze monochloramine solutions (NH2Cl) and ammonia solutions in a compact FTICR. Chemical ionization enables identification and quantification of the products present in the permeate. The responses of protonated monochloramine and ammonium increase linearly with the solution concentration. The enrichments were respectively 1.2 and 5.5. Pervaporation is dependent on pH and only the basic form of ammonia NH3 pervaporates through the membrane. Unexpectedly, the small ammonia molecule permeated very slowly. It could be due to interactions with water molecules inside the membrane that create clusters. Moreover, NH2Cl solutions, in addition to the NH3Cl+ signal, presented a strong NH4+ signal at m/z 18.034 . Ammonia presence in the low-pressure zone before ionization is probable as NH4+ was detected with all the precursors used, particularly CF3+ and trimethylbenzene that presents a proton affinity higher than monochloramine. Ammonia may be formed inside the membrane due to the fact that NH2Cl is unstable and may react with the water present in the membrane. Those results highlight the need for caution when dealing with chloramines in MIMS and more generally with unstable molecules.