Damion Corrigan

Dr. Damion Corrigan

University of Strathclyde
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2019 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
CRChristopher Russell
Christopher Russell
AWAndrew C. Ward
Andrew C. Ward
VVVincent Vezza
Vincent Vezza
PHPaul Hoskisson
Paul Hoskisson
DADavid Alcorn
David Alcorn
Damion CorriganDamion Corrigan
Damion Corrigan
This paper outlines a simple label-free sensor system for the sensitive, real time measurement of an important protein biomarker of sepsis, using a novel microelectrode integrated onto a needle shaped substrate. Sepsis is a life threatening condition with a high mortality rate, which is characterised by dysregulation of the immune response following infection, leading to organ failure and cardiovascular collapse if untreated. Currently, sepsis testing is typically carried out by taking blood samples which are sent to a central laboratory for processing. Analysis times can be between 12 and 72 h making it notoriously difficult to diagnose and treat patients in a timely manner. The pathobiology of sepsis is becoming increasingly well understood and clinically relevant biomarkers are emerging, which could be used in conjunction with a biosensor to support real time diagnosis of sepsis. In this context, microelectrodes have the analytical advantages of reduced iR drop, enhanced signal to noise ratio, simplified quantification and the ability to measure in hydrodynamic situations, such as the bloodstream. In this study, arrays of eight (r = 25 µm) microelectrodes were fabricated onto needle shaped silicon substrates and electrochemically characterised in order to confirm successful sensor production and to verify whether the observed behaviour agreed with established theory. After this, the electrodes were functionalised with an antibody for interleukin-6 (IL-6) which is a protein involved in the immune response to infection and whose levels in the blood increase during progression of sepsis. The results show that IL-6 is detectable at physiologically relevant levels (pg/mL) with incubation times as short as 2.5 min. Electrochemical impedance spectroscopy (EIS) and differential pulse voltammetry (DPV) measurements were taken and DPV was concluded to be the more suitable form of measurement. In contrast to the accepted view for macro electrodes that the impedance increases upon antigen bind, we report herein a decrease in the micro electrode impedance upon binding. The small size of the fabricated devices and their needle shape make them ideal for either point of care testing or insertion into blood vessels for continuous sepsis monitoring.

1 June 2019 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
EBEwen Blair
Ewen Blair
Damion CorriganDamion Corrigan
Damion Corrigan

1 January 2012 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
ICIlenia Ciani
Ilenia Ciani
Holger SchulzeHolger Schulze
Holger Schulze
Damion CorriganDamion Corrigan
Damion Corrigan
GHGrace Henihan
Grace Henihan
GGGerard Giraud
Gerard Giraud
AMAndrew R. Mount
Andrew R. Mount

13 March 2023 in ACS Sensors
Verified
Journal Article
Open access
PWPaul Williamson
Paul Williamson
PPPetteri Piskunen
Petteri Piskunen
HIHeini Ijäs
Heini Ijäs
ABAdrian Butterworth
Adrian Butterworth
Veikko LinkoVeikko Linko
Veikko Linko
Damion CorriganDamion Corrigan
Damion Corrigan

1 September 2021 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
MKM.S. Kumar
M.S. Kumar
RNRuchira Nandeshwar
Ruchira Nandeshwar
SLShailesh B. Lad
Shailesh B. Lad
KMKirti Megha
Kirti Megha
MMMaheshwar Mangat
Maheshwar Mangat
STSiddharth Tallur
Siddharth Tallur

7 February 2019 in Biosensors
Verified
Journal Article
Open access
PDF file
ABAdrian Butterworth
Adrian Butterworth
EBElizabeth Blues
Elizabeth Blues
PWPaul Williamson
Paul Williamson
MCMilovan Cardona
Milovan Cardona
LGLouise Gray
Louise Gray
Damion CorriganDamion Corrigan
Damion Corrigan
Antibiotic resistance is a growing concern in the treatment of infectious disease worldwide. Point-of-care (PoC) assays which rapidly identify antibiotic resistance in a sample will allow for immediate targeted therapy which improves patient outcomes and helps maintain the effectiveness of current antibiotic stockpiles. Electrochemical assays offer many benefits, but translation from a benchtop measurement system to low-cost portable electrodes can be challenging. Using electrochemical and physical techniques, this study examines how different electrode surfaces and bio-recognition elements, i.e. the self-assembled monolayer (SAM), affect the performance of a biosensor measuring the hybridisation of a probe for antibiotic resistance to a target gene sequence in solution. We evaluate several commercially available electrodes which could be suitable for PoC testing with different SAM layers and show that electrode selection also plays an important role in overall biosensor performance.