Arda Zaim

Dr. Arda Zaim

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 November 2025 in Processes
Verified
Journal Article
Open access
PDF file
Arda ZaimArda Zaim
Arda Zaim
This study presents an experimental optimization of an industrial-scale compressed air system aimed at improving energy efficiency and operational performance. The evaluation was conducted in accordance with ISO 11011 standards, covering supply, distribution, demand, and air quality aspects. Reference and optimized scenarios were directly compared under equivalent operating conditions. The most significant improvement was the elimination of a 0.54-bar pressure drop, which enabled the compressor’s set pressure to be reduced from 7.0 bar to 6.5 bar and prevented unnecessary load cycles. In addition, the detection and repair of leakage points significantly reduced constant loads during non-production hours. As a result, average power consumption decreased by 32.6%, while idle consumption was reduced by 70%. Improvements in filtration and condensate management lowered moisture and oil carryover, thereby enhancing process reliability. Considering annual operating hours, the optimization was estimated to offer a potential reduction of approximately 63.5 tons of CO2 emissions. The results demonstrate that substantial efficiency and sustainability gains can be achieved through physical adjustments and operational measures without modifying control algorithms.

15 May 2020 in Mühendis ve Makina
Verified
Journal Article
Closed access
PDF file
Arda ZaimArda Zaim
Arda Zaim
HAHaydar Aras
Haydar Aras
Artan nüfus ve gelişen teknolojiyle birlikte enerji tüketimi ve maliyetleri günden güne artış göstermektedir. Ülkemiz fosil enerji kaynakları bakımından sınırlı kaynaklara sahip ve dışa bağımlıdır. Enerji ihtiyacının güvenilir, ekonomik ve yeterli bir biçimde karşılanabilmesi temel amaçtır. Bu bağlamda enerjinin verimli kullanımı üzerinde önemle durulması gereken hususlar arasında yer almaktadır. Enerji verimliliği, harcanan enerji miktarının, üretimdeki kapasite ve kaliteyi azaltmadan, ekonomik kalkınmayı ve sosyal refahı engellemeden en aza indirilmesidir. Bu çalışmada, endüstride en çok kullanılan ikincil enerji kaynağı basınçlı havayla çalışan pnömatik sistemlerdeki enerji verimliliği uygulamaları ele alınmış ve deneysel çalışmalarla desteklenmiştir. Basınçlı hava sistemi tasarımında verimliliği artıran unsurlar belirlenmiş; kompresör, silindir ve vakum ejektörü gibi pnömatik iş elemanlarında işletme basınçlarının düşürülmesiyle elde edilebilecek tasarruf miktarları hesaplanmıştır. Ciddi maliyetler oluşturan hava kaçaklarının tespiti ve maliyeti konusunda fiziki bulgular incelenmiş, enerji tasarruf fonksiyonlu ürünlerin kullanımı için yol gösterilmiştir. Çalışmanın, enerji arzında büyük oranda dışa bağımlı olan ülkemizin sanayi sektöründe enerji yoğunluğunun düşürülmesi ve karbon ayak izinin azaltılması faaliyetlerinde bir rehber niteliği taşıyacağı düşünülmektedir.

8 August 2025 in Case Studies in Thermal Engineering
Verified
Journal Article
Open access
HAHaydar Aras
Haydar Aras
Arda ZaimArda Zaim
Arda Zaim

13 February 2026 in Machines
Verified
Journal Article
Open access
PDF file
Arda ZaimArda Zaim
Arda Zaim
HAHaydar Aras
Haydar Aras
In this study, software-based, measurement-driven automation and control architecture is developed for magnetic refrigeration systems. The proposed structure integrates real-time measurement data obtained from magnetic, hydraulic, and thermal sub-processes within a single decision layer. Control actions are generated based on cycle-level performance feedback. Instead of directly regulating absolute performance values, the control logic relies on performance trends between successive cycles as the primary decision variable. The method is experimentally implemented on a reciprocating magnetic refrigerator prototype. The system is first operated with fixed parameters, after which cycle-level adaptation is activated using measurement-based decisions. Experimental results show that adaptive control drives the system toward a stable and high-performance regime following a short transient phase. The average coefficient of performance (COP) increases from approximately 0.21 under manual operation to about 1.20 in adaptive operation, while cycle-to-cycle fluctuations are significantly reduced. The results indicate that operation based on fixed timing and preset parameters is insufficient for magnetic refrigeration systems. In contrast, software-based control using cyclic feedback shifts the system to a more stable and efficient regime. The proposed architecture provides a high-level control framework with low hardware dependency and can be adapted to different magnetic refrigeration configurations.

30 September 2018 in Academic Platform Journal of Engineering and Smart Systems
Verified
Journal Article
Closed access
AAAgah Aygahoğlu
Agah Aygahoğlu
Arda ZaimArda Zaim
Arda Zaim

28 September 2026 in Dicle Üniversitesi Mühendislik Fakültesi Mühendislik Dergisi
Verified
Journal Article
Closed access
Arda ZaimArda Zaim
Arda Zaim
Compressed air is one of the primary energy carriers used to operate pneumatic equipment and industrial processes. Moisture control is important for achieving the required air quality at the point of use. Refrigerated dryers reduce the moisture content of compressed air by condensing water vapor. Industrial field studies that jointly examine the hydraulic behavior and pressure dew point performance of refrigerated dryer lines under variable production demand remain limited. This study evaluated the hydraulic and pressure dew point performance of an industrial refrigerated dryer line under actual production conditions. Volumetric flow rate, line pressure, line pressure drop, and outlet pressure dew point were measured simultaneously. The flow rate ranged from 8.37 to 23.59 m³ min⁻¹. Line pressure drop ranged from 0.081 to 0.665 bar. The ratio of pressure drop to inlet pressure reached a maximum of 10.48%. The slope of the relationship between flow rate and pressure drop increased at higher flow rates. After initial conditioning, the outlet pressure dew point remained below the +3 °Ctd limit defined for water in ISO 8573-1. Short term changes in flow rate and pressure drop were not reflected in the outlet pressure dew point on the same time scale. This study provides field data at the system level for the simultaneous assessment of pressure dew point performance and hydraulic behavior under variable production demand.