Michel Yves Haller

Dr. Michel Yves Haller

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2009 in Solar Energy
Verified
Journal Article
Closed access
MHMichel Yves Haller
Michel Yves Haller
CCCynthia A. Cruickshank
Cynthia A. Cruickshank
WSWolfgang Streicher
Wolfgang Streicher
SHStephen J. Harrison
Stephen J. Harrison
EAElsa Andersen
Elsa Andersen
SFSimon Furbo
Simon Furbo

1 June 2010 in Solar Energy
Verified
Journal Article
Closed access
MHMichel Yves Haller
Michel Yves Haller
EYEshagh Yazdanshenas
Eshagh Yazdanshenas
EAElsa Andersen
Elsa Andersen
CBChris Bales
Chris Bales
WSWolfgang Streicher
Wolfgang Streicher
SFSimon Furbo
Simon Furbo

1 January 2014 in Energy Procedia
Verified
Journal Article
Open access
DCDaniel Carbonell
Daniel Carbonell
MHMichel Yves Haller
Michel Yves Haller
DPDaniel Philippen
Daniel Philippen
EFElimar Frank
Elimar Frank
The system combination of solar thermal collectors and heat pumps is a very attractive option for increasing the renewable energy usage at worldwide level for heating and domestic hot water preparation. In this work parallel and series combined solar and heat pump systems are analyzed within the IEA SHC Task44/HPP Annex38 reference conditions for different buildings and a typical Central European climate. Three combined systems have been studied in detail: solar and air source heat pump, solar and ground source heat pump, and exclusively solar source heat pump in combination with an ice storage. Numerical calculations have been performed using two simulation platforms: TRNSYS-17 and Polysun-6®. Comparisons between the two simulation environments have been also provided. Moreover, a reference case without solar has been used to determine the potential efficiency benefits of using solar collectors compared to a system with a heat pump alone in the specified climate and for covering the specified heat load. Simulations presented in this work show that differences in system performance up to 4% can be expected between TRNSYS-17 and Polysun-6® for air source based systems, and higher discrepancies, up to 14% are obtained for ground source based systems. Comparisons between combined solar thermal and heat pump systems with their respective “heat pump only” reference solutions show that the absolute electricity savings of air source are usually higher compared to ground source based systems. Systems using large ice storages are able to reach seasonal performance factors in the range of 5, which is of the order of performance of combined solar and ground source heat pump systems

1 January 2016 in Applied Energy
Verified
Journal Article
Closed access
SPStefano Poppi
Stefano Poppi
CBChris Bales
Chris Bales
MHMichel Yves Haller
Michel Yves Haller
AHAndreas Heinz
Andreas Heinz

1 November 2013 in Energy and Buildings
Verified
Journal Article
Closed access
MHMichel Yves Haller
Michel Yves Haller
RHR. Haberl
R. Haberl
TPT. Persson
T. Persson
CBC. Bales
C. Bales
PKP. Kovacs
P. Kovacs
PPP. Papillon
P. Papillon

1 January 2014 in Energy Procedia
Verified
Journal Article
Open access
DCD. Carbonell
D. Carbonell
MHMichel Yves Haller
Michel Yves Haller
EFE. Frank
E. Frank
In this work, the combination of solar thermal systems with heat pumps has been numerically analyzed. Potential benefits have been studied by comparing systems that use only a heat pump with combined systems. All simulations were carried out with Polysun-6® for several climates around Europe. The simulated systems are designed to provide space heat and domestic hot water for single family houses.Results presented in this work show that the seasonal performance factor of the overall heating system increases when a solar thermal system is added for both air source and ground source heat pumps. The performance of the ground source heat pump alone also tends to increases when it is combined with a solar thermal system. On the other hand, the performance of the air source heat pump alone decreases when it is combined with a solar thermal system. For this reason, in terms of fractional electricity savings, the potential benefit of ground source based systems is higher than that of an air source heat pump. Obviously the energetic benefit also increases with collector area and solar radiation.In terms of absolute electricity savings, the benefit of adding solar thermal to a heat pump system increases with the electric energy consumption of the reference system without the solar thermal part. Therefore air source systems have usually higher potential compared to ground source based systems despite of the lower fractional electricity savings. For the same reason, systems with high energy demand, e.g. systems in colder climates or with lower building insulation standard; will also benefit more than those of low energy demand. The optimum climate in terms of absolute electricity savings is found in a typical alpine location with cold climate but at the same time high irradiation in winter