The dynamic error is the dominant factor affecting multi-axis CNC machining accuracy. Predicting and compensating for dynamic errors is vital in high-speed machining. This paper proposes a novel prediction-model-based approach to predict and compensate for the ball screw feed system’s dynamic error. Based on the lumped and distributed mass methods, this method constructs a parameterized dynamic model relying on the moving component’s position for electromechanical coupling modeling. Using Latin Hypercube Sampling and numerical simulation, a sample set containing the input and output of one control cycle is obtained, which is used to train a Cascade-Forward Neural Network to predict dynamic errors. Finally, a feedforward compensation strategy based on the prediction model is proposed to improve tracking performance. The proposed method is applied to a ball screw feed system. Tracking error simulations and experiments are conducted and compared with the transfer function feedforward compensation. Typical trajectories are designed to validate the effectiveness of the electromechanical coupling model, the dynamic error prediction model, and the feedforward compensation strategy. The results show that the prediction model exhibits a maximum prediction deviation of 1.8% for the maximum tracking error and 13% for the average tracking error. The proposed compensation method with friction compensation achieves a maximum reduction rate of 76.7% for the maximum tracking error and 63.7% for the average tracking error.
18 April 2019 in IET Generation, Transmission & Distribution
The randomness of new energy generation and variation in load demands bring uncertainty to large AC/DC grids. Traditional deterministic power flow equations have difficulty coping with the uncertainties of new energy generation and load. Here, an affine arithmetic (AA)‐based uncertainty power flow algorithm for hybrid AC/DC grids incorporating voltage source converters (VSCs) is presented. VSC station and DC grid models are established using AA. Diverse VSC control modes are considered in the power flow iterations. A comparison using the Monte–Carlo method shows that the proposed algorithm is able to obtain a feasible solution. The proposed method can be used by power system operators and planners to monitor and control AC/DC grids under various uncertainties.
In order to disguise and hide themselves better, vessels and submarines are equipped with degaussing windings. But, with the development of warship degaussing technology, more and more degaussing coils are being adopted. Thus, conventional methods to calibrate the degaussing system are increasingly difficult to implement. In order to solve this problem, the improved poly-population particle swarm algorithm is applied to compress the search space, which can improve the probability of searching global optimization solution. This method is applied to adjust some vessel degaussing system. Simulation results show that this algorithm has more advantages than others, in terms of minimizing the degaussing magnetic field characteristic RMS value (min-RM) and peak value (min-PM), and that this method can be used to optimize one or more parameters relating to the vessel or submarine's magnetic field characteristics, so the vessel or submarine degaussing system is calibrated to an optimal state, and the vessel or submarine's magnetic safety is ensured. Furthermore, this optimization has many advantages, such as intuitional algorithm, simple programming, high calculating speed, etc., which makes easy collaborating multi-computer and applying it to real project.
Nowadays, tidal current power generation has become one of the new energy sources that greatly attract researchers, due to its nonpollution and durative. Because the distribution density of tidal current energy is asymmetric everyday, the electrical power produced by the generators is also unstable AC. The keystones to developing tidal current power generation system include: developing energy conversion system with high reliability and efficiency, and generator system with high quality. Regarding an actual design of tidal current power station in Jiangxia, Zhejiang Province, China, as an example, a kind of power energy control method based on AC-DC-AC frequency conversion and electrical power compensation was given, and a grid-connection closed-loop control method based on grid-connected current tracking was discussed. Application results showed that this method could solve the problem that the power of tidal current is unstable, and improve the efficiency and reliability of grid-connection of tidal current power station.
26 February 2022 in Proceedings of the Institution of Mechanical Engineers, Part B: Journal of Engineering Manufacture
Dynamic performance characterized by lower-order natural frequency and lower-order vibration mode is vital for the dynamic positioning accuracy of the ball screw feed system. This paper focuses on the evolution between the lateral vibration mode and the axial vibration mode of the slender ball screw feed system (SBSFS). Firstly, it is proved the first-order vibration mode transformation of the SBSFS is subject to the position of the nut based on an elastodynamic model. This model is established using substructure synthesis method considering the axial, torsional, and lateral deformation of the screw simultaneously through dealing with the screw as Timoshenko Beam elements. By comparing with the experimental results, the validity and accuracy of the established dynamic model are verified. The effects of the stiffness of the kinematic joints on the dynamic performance of SBSFS are then analyzed. The results demonstrate that the dynamic behavior evolution of the SBSFS undergoes the coupling effects from the kinematics joints’ stiffness. Furthermore, a dynamic index ( RSP) is proposed considering the evolution of the first-order vibration mode. On the basis of RSP, three optimization schemes are illustrated. The results show that the RSP can be used to evaluate the dynamic performance of the SBSFS considering the vibration mode.