Tatiana Guerrero-David

Dr. Tatiana Guerrero-David

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 April 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
SMShirin Madarshahian
Shirin Madarshahian
MTMichael Trakhtorchuk
Michael Trakhtorchuk
TGTatiana Guerrero-David
Tatiana Guerrero-David
KGKristin Gustafson
Kristin Gustafson
JHJames S Harrop
James S Harrop
MSMijail Serruya
Mijail Serruya
Transcutaneous spinal cord stimulation (tSCS) is a promising non-invasive method to improve motor function in individuals with spinal cord injury (SCI) by enhancing spinal reflex pathways. This study aimed to investigate the effects of different tSCS electrode placement montages and targeted spinal levels on neurophysiological responses such as spinally evoked motor responses (sEMRs), dorsal root reflex activation, and muscle recruitment in individuals with SCI and healthy controls to optimize stimulation strategies for motor recovery. Five participants (three individuals with SCI and two controls) underwent transcutaneous spinal cord stimulation using various electrode montages, target spinal level stimulation, and single- and paired-pulse paradigms. Electromyographic responses were analyzed to determine sEMR threshold, amplitudes, and paired-pulse attenuation. Different spinal levels and spatial configurations of electrode placements influenced the sEMR threshold and incidence of sEMR across all participants. Paired-pulse analysis showed more pronounced second-pulse attenuation in SCI participants (48 ± 36%) than in controls (12 ± 20%, p = 0.0425), with distinct trends observed across montages and muscle groups. These findings suggest that spinal level, electrode configuration, and paired-pulse effects are key factors in personalizing tSCS, informing the development of patient-centered therapeutic strategies. Future studies with larger and more diverse cohorts are needed to validate and expand these findings.

19 May 2026 in Technology and Disability
Verified
Journal Article
Closed access
MTMichael Trakhtorchuk
Michael Trakhtorchuk
SMShirin Madarshahian
Shirin Madarshahian
RNRajkishen Narayanan
Rajkishen Narayanan
AFAli Farooqi
Ali Farooqi
JDJonathan Dalton
Jonathan Dalton
MSMijail Serruya
Mijail Serruya
Study design: Prospective trial. Objective: To evaluate the impact on muscle activation of different anatomical configurations of transcutaneous spinal cord stimulation electrodes amongst SCI and control patients. Summary of background data: Spinal cord stimulation has garnered increased attention as a promising treatment for spinal cord injury (SCI). However, existing studies on transcutaneous spinal cord stimulation consist of highly variable methodologies and lack standard protocols. Methods: Two adult SCI participants (PS01—T12 AIS D, and PS02—T2 AIS B) and two healthy adult controls (PS03, and PS04) were prospectively enrolled after IRB approval. Electromyography was used to record activity in the bilateral tibialis anterior (TA) and biceps femoris (BF). Four electrode configurations were trialed—cathode placement only at T11-T12 (montage T11-T12) versus combined configurations with cathodes at T11-T12 and at L1-L2, L3-L4, or S1-S2; anode placement was always at the bilateral iliac crests. Motor response was defined as EMG change >20 μV, as defined in the literature. Results: SCI participants exhibited overall decreased motor responses compared to controls, other than PS01 at the T11-T12 montage. The majority of motor responses from SCI participants did not meet the 20 µV threshold, and did not show the same consistent cranial to caudal pattern. PS01’s highest response was at T11-T12/L1-L2 (BF: 265.52 µV), whereas PS02 was highest at T11-T12 (TA: 39.73 µV). Overall, the motor response from the motor complete SCI (PS02—T2 AIS B) was substantially less than the motor response from the motor and sensory incomplete SCI. Conclusion: When performing transcutaneous spinal cord stimulation, the magnitude of motor response appears to vary with both the exact anatomical electrode configuration and the presence/severity of SCI. SCI participants demonstrated generally decreased motor responses, and a less predictable topographic pattern. Further work is needed to determine the ideal electrode configurations for different patients and spinal cord injury types.