Xinran Wang

Dr. Xinran Wang

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 November 2026 in Physical Review Accelerators and Beams
Verified
Journal Article
Open access
LTLingjun Tu
Lingjun Tu
YLYifan Liang
Yifan Liang
HSHao Sun
Hao Sun
LZLi Zeng
Li Zeng
HYHuaiqian Yi
Huaiqian Yi
XYXueming Yang
Xueming Yang
Broadband tunability is a key pursuit for terahertz (THz) free-electron lasers, yet it is often constrained by the narrow energy acceptance of laser modulators in prebunched schemes. Here, we propose a harmonic modulation scheme to decouple this constraint. Taking the Electron Source Test Facility at Dalian as a specific case study, our simulations demonstrate that by matching the laser field to higher-order harmonic resonances of the undulator, we can obtain efficient energy modulation across a significantly wider electron energy range (40–130 MeV), surpassing the limit of 71–130 MeV imposed by the fundamental resonance. This technique facilitates continuous frequency tuning from 0.5 to 30 THz using a single modulator-radiator chain, establishing a versatile method for ultrabroadband THz generation.

30 May 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
XWXinran Wang
Xinran Wang
GCGuiling Cao
Guiling Cao
WZWenzhi Zhang
Wenzhi Zhang
Particle radiotherapy based on the medical accelerator is emerging as a major treatment for cancer. To enhance the clinical flexibility of particle radiotherapy and further promote the use of medical accelerators, the Shanghai Institute of Applied Physics (SINAP) has presented a new linear accelerator plan for medical application. The new plan utilizes a 200 MHz Radio Frequency Quadrupole (RFQ) as the injector. The RFQ is designed to accelerate ions with charge-to-mass ratios of 1/3 to 1/2 from 8 keV/u to 750 keV/u. For the beam dynamics design, a new design strategy is presented to enhance the suppression of space charge effects and improve beam capture efficiency by optimizing the modulation, synchronous phase, and focusing strength. The simulation results demonstrate that the multi-ion RFQ can operate at a maximum beam current of 3.2 mA while maintaining a transmission efficiency above 95% with a compact length of 2.5 m. Multi-particle simulations confirm the high reliability of the design. Additionally, input and mechanical error analyses evaluate the RFQ’s tolerance and stability. The research results demonstrate the feasibility of a compact, high-efficiency RFQ for multi-ion acceleration in medical applications, contributing to the advancement of particle therapy.