Background. Chronic lung allograft dysfunction (CLAD), and especially bronchiolitis obliterans syndrome (BOS), remain dominant causes of morbidity and mortality after lung transplantation. Interest is growing in the forced oscillation technique, of which impulse oscillometry (IOS) is a form, as a tool to improve our understanding of these disorders. However, data remain limited and no longitudinal studies have been published, meaning there is no information regarding any capacity IOS may have for the early detection of CLAD. Methods. We conducted a prospective longitudinal study enrolling a consecutive sample of adult bilateral lung transplant recipients with healthy lung allografts or CLAD and performed ongoing paired IOS and spirometry tests on a clinically determined basis. We assessed for correlations between IOS and spirometry and examined any predictive value either modality may hold for the early detection of BOS. Results. We enrolled 91 patients and conducted testing for 43 mo, collecting 558 analyzable paired IOS and spirometry tests, with a median of 9 tests per subject (interquartile range, 5–12) and a median testing interval of 92 d (interquartile range, 62–161). Statistically significant moderate-to-strong correlations were demonstrated between all IOS parameters and spirometry, except resistance at 20 Hz, which is a proximal airway measure. No predictive value for the early detection of BOS was found for IOS or spirometry. Conclusions. This study presents the first longitudinal data from IOS after lung transplantation and adds considerably to the growing literature, showing unequivocal correlations with spirometry but failing to demonstrate a predictive value for BOS. Export
Background: BK virus-associated nephropathy (BKVAN) is a relatively common cause of renal dysfunction in the first six months after renal transplantation. It arises from reactivation of the latent and usually harmless BK virus (BK virus) due to immunosuppression and other factors including some that are unique to renal transplantation such as allograft injury. BKVAN is much rarer in non-renal solid organ transplantation, where data regarding diagnosis and management are extremely limited.Case presentation: We report a case of a 58-year-old man found to have worsening renal dysfunction nine months after bilateral sequential lung transplantation for chronic obstructive pulmonary disease (COPD). He had required methylprednisolone for acute allograft rejection but achieved good graft function. Urine microscopy and culture and renal ultrasound were normal. BK virus PCR was positive at high levels in urine and blood. Renal biopsy subsequently confirmed BKVAN. The patient progressed to end-stage renal failure requiring haemodialysis despite reduction in immunosuppression, including switching mycophenolate for everolimus, and the administration of intravenous immunoglobulin (IVIG).Conclusions: This very rare case highlights the challenges presented by BK virus in the non-renal solid organ transplant population. Diagnosis can be difficult, especially given the heterogeneity with which BKV disease has been reported to present in such patients, and the optimal approach to management is unknown. Balancing reduction in immunosuppression against prevention of allograft rejection is delicate. Improved therapeutic options are clearly required.
Cystic fibrosis (CF) is an inherited multisystem disease characterised by bronchiectasis and chronic respiratory infections which eventually cause end stage lung disease. Lung transplantation (LTx) is a well-established treatment option for patients with CF-associated lung disease, improving survival and quality of life. Navigating recurrent infections in the setting of LTx is often difficult, where immune suppression must be balanced against the constant threat of infection. Sepsis/infections are one of the major contributors to post-LTx mortality and multiresistant organisms (eg, Burkholderia cepacia complex, Mycobacterium abscessus complex, Scedosporium spp. and Lomentospora spp.) pose a significant threat to survival. This review will summarize current and novel therapies to assist with the management of multiresistant bacterial, mycobacterial, viral and fungal infections which threaten the CF LTx cohort.
There are few cases of multiple bronchial stenoses reported in the literature and none of the severity described here. The case is relevant due to its rareness, the pathophysiological insights derived, the successful interventional pulmonology strategies demonstrated, and as an example of a rare indication for high-risk lung transplantation. A 47-year-old man developed multiple recurrent bronchial web-like stenoses five weeks after an episode of severe tracheo-bronchitis presumed secondary to a chemical inhalation injury which initially caused complete bilateral lung collapse necessitating veno-venous extracorporeal membrane oxygenation. The stenoses completely effaced bronchi in many locations causing severe type II respiratory failure requiring mechanical ventilation and bronchoscopic puncture / dilatation then ultimately bilateral lung transplantation. This very rare case highlights the morbid sequelae that can arise after catastrophic tracheobronchitis which now, in the era of extracorporeal membrane oxygenation, may be survivable in the short-term.
Background: Disproportionate bulging of the pars membranosa into the central airway on expiration, now termed ‘excessive dynamic airway collapse’ (EDAC), has poorly characterised significance. Despite physiological arguments supporting an association between obstructive sleep apnoea (OSA) and dynamic intra-thoracic central airway collapse, this is unproven. Methods: An audit was conducted of patients having had both a dynamic CT chest and a diagnostic polysomnogram between 2009 and 2018 and within 2 years of one another. Dynamic airway collapse was quantified by the presence of EDAC (≥75% collapse) at any of five sites plus a composite index of mean cross-sectional area (CSA) change. Linear regression models were used to assess associations between pre-defined variables. Results: A total of 59 patients was included. Median apnoea-hypopnoea index (AHI) was 13 events/hour (IQR: 5–31 events/hour | range 0–153 events/hour). EDAC was not identified. Median composite dynamic airway collapse index was 18% (IQR: 9–30% | range: 0–63%). Unadjusted and adjusted linear regression analyses demonstrated statistically significant associations between degree of dynamic intra-thoracic central airway collapse and multiple OSA indices. In the adjusted model, every 10% worsening in dynamic airway collapse was associated with an increase in apnoea-hypopnoea index (AHI) of 5 events/hour (95% confidence interval: 0.9–10 events/hour | p = 0.019). No association was found between dynamic airway collapse and symptoms or healthcare utilisation. Conclusions: This study supports an association between dynamic intra-thoracic central airway collapse and OSA, despite the failure to identify EDAC, which was likely due to retrospectively audited CT scans not being performed to research standards.