Zauresh M. Zhambakina

Zauresh M. Zhambakina

Auto-generated profile, based on publicly available information

Zauresh M. Zhambakina


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 May 2024 in Buildings
Verified
Journal Article
Open access
PDF file
YBYerik Bessimbayev
Yerik Bessimbayev
SNSayat Niyetbay
Sayat Niyetbay
Talal AwwadTalal Awwad
Talal Awwad
EKErzhan Kuldeyev
Erzhan Kuldeyev
SUSaken Uderbayev
Saken Uderbayev
ZZZauresh M. Zhambakina
Zauresh M. Zhambakina
This paper presents the results of a study on the relevance of seismic isolation systems for protecting architectural monuments from seismic and vibration impacts. This work aims to develop a method for protecting architectural monuments from seismic and vibration effects by installing geotechnical seismic isolation systems made of various geomaterials, such as a silicate soil mixture (SSM), a cement–soil mixture (CSM), a bitumen–soil mixture (BSM), and a rubber–soil mixture (RSM). The novelty of the work lies in the results of studying the wave processes in different models of geomaterials to assess their effectiveness in a seismic isolation system in the form of damping barrier screens to ensure the seismic resistance of architectural monuments. By comparing the amplitude–frequency characteristics of various geomaterials, it was found that the rubber–soil mixture (RSM), the cement–soil mixture (CSM), and the bitumen–soil mixture (BSM) have the most effective damping properties. A proposed method for protecting architectural monuments with geotechnical seismic isolation in the form of vertical screen barriers and technology for their installation ensures the integrity and safety of architectural monuments at all stages of construction and operation.

30 June 2022 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
YBYerik Bessimbayev
Yerik Bessimbayev
ZZZauresh Zhambakina
Zauresh Zhambakina
SNSAYAT NIYETBAY
SAYAT NIYETBAY
This paper considers the issue related to the protection of buildings and structures against seismic influences and the prevention, exclusion, or reduction of seismic hazards. The catastrophic destruction of modern «earthquake-resistant» buildings in Turkey and Taiwan has shown that existing methods of strengthening and reinforcing structures are not perfect and require further study. Analysis of existing approaches to ensuring seismic resistance showed that seismic insulation and seismic suppression systems still do not have a scientific and technical justification for the effectiveness of their operation from the point of view of ensuring the stability of structures. The estimation-dynamic models of the «base-seismic insulation-structure» system developed to date do not always make it possible to simulate the joint work of their interaction during an earthquake and account for the transformation of the seismic impact on the structure. An alternative technique has been devised, a geotechnical seismic insulation screen, as a seismic insulation system that reduces the intensity of seismic loads on the structure and ensures its seismic resistance. In a specific example, the effectiveness of this seismic insulation system is confirmed. This seismic insulation technique in the form of damper screens is characterized by reliability and manufacturability in ensuring the seismic resistance of objects under construction. The results of computational and experimental modeling of the interaction of an earthquake-insulated structure with a ground base found that the values of axial forces and bending moments in a building with a seismic insulating screen are less than in a building without seismic insulation by 30‒40 %. The geotechnical seismic insulation screen makes it possible to advance the development of new seismic insulation techniques and determine their effectiveness. This technique will also be effective when strengthening the base and seismic insulation systems of historical monuments, protecting them against seismic and dynamic influences.

4 June 2024 in Buildings
Verified
Journal Article
Open access
PDF file
ITIlia Teshev
Ilia Teshev
ABAliy Bespayev
Aliy Bespayev
ZZZauresh Zhambakina
Zauresh Zhambakina
MTMurat Tamov
Murat Tamov
UAUlan Altigenov
Ulan Altigenov
Aigerim TolegenovaAigerim Tolegenova
Aigerim Tolegenova
This article presents the results of experimental studies of the stress–strain state of volumetric blocks based on the underlying frame structures. The aim of the research is to evaluate the stress–strain state and the nature of damage development as a result of an increase in the load up to a critical level. Based on the analysis of the nature of the damage, recommendations have been developed to strengthen the destruction zone. Data were collected on the redistribution of stresses and deformations, the formation of cracks and joint openings, the magnitude of horizontal displacements, and the failure mode of volumetric blocks and floor frames. Five full-scale volumetric blocks were tested under the loading of hydraulic jacks, differing in concrete type, reinforcement, presence of doors, and dimensions of the stylobate beams. When the volumetric modules were supported by a frame floor the results revealed that the maximum destructive load of 10,462 kN was observed in the first specimen; the horizontal displacements of the walls decreased by 13–18 mm, and there was a decrease in the crack opening width to 0.5 mm. The cracks decreased the strength of the walls, leading to a redistribution of the compressive stresses and their increase in the support zone. The most significant compressive strains in concrete in the corner parts of longitudinal walls were in the range of (600–620) × 10−6, and in the middle part of the walls, 370 × 10−6 were observed. Furthermore, the largest cracks caused significant horizontal displacements (deplanation) of the walls, which decreased the stiffness of the conjunction of longitudinal walls with the floor slab and created an additional eccentricity of the vertical force. Based on the findings, the correlation between the measured parameters of each specimen at all stages of vertical load increase is demonstrated and illustrated in graphs of the measured parameters. The importance of quantity compliance with the initial rigid connection between the longitudinal wall and ceiling plate has been estimated.

15 April 2020 in SERIES CHEMISTRY AND TECHNOLOGY
Verified
Journal Article
Closed access
TKT.к. Kuatbayeva
T.к. Kuatbayeva
ZNZh. Т. Nashiraliyev
Zh. Т. Nashiraliyev
ZZZ. М. Zhambakina
Z. М. Zhambakina
МBМ. G. Bruyako
М. G. Bruyako
АOА. Т. Orynova
А. Т. Orynova
The article considers the issues of technology of silicate materials of dense and cellular structure with usage of oil bituminous rocks and waste from their processing, in particular: the optimization of the ratios of the raw components of a silicate materials mixture, the development of optimal technological parameters for the production of silicate materials, and the technological aspects of the production of the above materials. The optimal compositions of binders with use of waste products from OBR are studied in this work as an activating component of lime or cement. The stability of the samples was studied in various media with a low and high content of basic calcium hydrosilicate. If they contain insoluble silicates and aluminosilicates containing silica, they are acid resistant. Alkali-resistant rocks containing oxides corresponding to strong bases are combined with oxides corresponding to weak acids, for example, calcium and magnesium carbonates. As a result of the experimental work, technological processes for the manufacture of silicate materials (of dense and cellular structure) based on the OBR and waste from their processing are substantiated and developed. The paper reveals the chemical-mineralogical and the structural features of oil bituminous rocks and waste from their processing. The optimal ratio of the waste mixture of oil and bituminous rocks with lime and the technological parameters that ensure the grade of lime-sand binder from 400 to 500 are established. Silicate materials based on this mixture have high physical and mechanical properties and comply with the requirements of the ST standards of the Republic of Kazakhstan for silicate brick and GOST state standard for aerated concrete. Thus, the compositions and conditions for the preparation of these binders with high resistance in large temperature, pressure and aggressive environments are proposed in this work. Key words: oil bituminous rocks and waste from their processing, structure, mechanochemical activation, silicate materials, binder, cellular concrete, durability.

15 June 2020 in Series of Geology and Technical Sciences
Verified
Journal Article
Closed access
ZZZ. M. Zhambakina
Z. M. Zhambakina
NKN. V. Kozyukova
N. V. Kozyukova
JNJ. T. Nashiraliev
J. T. Nashiraliev
TKT. K. Kuatbaeva
T. K. Kuatbaeva
MBM. G. Bruyako
M. G. Bruyako

10 April 2025 in Buildings
Verified
Journal Article
Open access
PDF file
ITIlia Teshev
Ilia Teshev
ABAliy Bespayev
Aliy Bespayev
MTMurat Tamov
Murat Tamov
ZZZauresh Zhambakina
Zauresh Zhambakina
UAUlan Altigenov
Ulan Altigenov
Aigerim TolegenovaAigerim Tolegenova
Aigerim Tolegenova
Modular construction is a modern and efficient type of construction that has gained wide recognition in the construction industry. Limited research has been conducted on how large door openings affect the stress state of modular blocks. The present study aims to investigate the features of the stressed state of modular blocks with large door openings and the effect of size and place of the doors on the openings on the overall structural behavior of the building. Four full-scale (room-sized) modular blocks of the “lying cup” type were tested to failure under vertical loading with eccentricity simulating wind effects. The varied parameters of the specimens included concrete strength and the size of the window openings. Experimental results revealed that crack opening characteristics, main load-bearing wall deformations, horizontal deflections, and failure patterns under vertical loads are directly influenced by the small thickness and increased flexibility of the blocks. The effects of size and the placement of openings on the overall structural behavior of the building were analyzed. Tests revealed the distribution of compressive stresses in the main load-bearing walls of the “lying cup” blocks with an embedded reinforced concrete panel, considering vertical load eccentricity. Maximum compressive stresses in the longitudinal walls reached 70–80% of concrete strength, while in end walls and panel walls, they were 50–60%. Additionally, non-uniform deformations were observed in the supports of main load-bearing walls near the conjunction with the end walls and the edges of door openings. Average compressive strains in these walls were in the range of 470–500 × 10−6, which corresponds to 22–29% of the cylindrical compressive strength of concrete. Partial factors accounting for loading conditions were introduced, allowing for further processing and the evaluation of the experimental data along with developing methods of analysis of buildings constructed with modular blocks.