Hao Liu

Dr. Hao Liu

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 May 2018 in Energies
Verified
Journal Article
Open access
PDF file
HLHao Liu
Hao Liu
NMNadali Mahmoudi
Nadali Mahmoudi
KCKui Chen
Kui Chen
Microgrids are widely spreading in electricity markets worldwide. Besides the security and reliability concerns for these microgrids, their operators need to address consumers’ pricing. Considering the growth of smart grids and smart meter facilities, it is expected that microgrids will have some level of flexibility to determine real-time pricing for at least some consumers. As such, the key challenge is finding an optimal pricing model for consumers. This paper, accordingly, proposes a new pricing scheme in which microgrids are able to deploy clustering techniques in order to understand their consumers’ load profiles and then assign real-time prices based on their load profile patterns. An improved weighted fuzzy average k-means is proposed to cluster load curve of consumers in an optimal number of clusters, through which the load profile of each cluster is determined. Having obtained the load profile of each cluster, real-time prices are given to each cluster, which is the best price given to all consumers in that cluster.

1 May 2016 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
TYTang Yi
Tang Yi
HJHou Jie
Hou Jie
HLHao Liu
Hao Liu
WLWen Lei
Wen Lei
Locating the voltage sag source is to determine on which side of a monitoring device the voltage sag originates. By analysing power network faults, observing from fault points to monitoring devices, power network at both sides of the device can be equivalent to two single‐port networks. Based on the polarity of real part of internal impedance in these two single‐port networks, the voltage sag source location can be identified accurately. If the real part of internal impedance is positive, the voltage sag source location is consistent with the reference direction, i.e. downstream. If the real part of internal impedance is negative, the voltage sag source location is opposite to the reference direction, i.e. upstream. The calculation of the real part of internal impedance is presented. The method proposed in this study has a solid theoretical basis. Simulation results show the method can locate voltage sag source with an accuracy of 100%, in power networks with various topologies (e.g. radial power system fed from one‐source or multiple‐source, interconnected power system, ring type network etc.), and the network adopted neutral grounded effectively or ineffectively. It is a practical method with high reliability for voltage sag source location.