Purpose A case of subacute combined degeneration (SCD) of the spinal cord manifesting as severe ataxia and urinary retention in a patient with a history of heavy nitrous oxide abuse and self-supplementation with cyanocobalamin is reported. Summary A 27-year-old woman was treated in the emergency department for complaints of abdominal pain and inability to urinate for about 12 hours. The patient also complained of worsening lower-extremity weakness for 10 days and a “pins and needles” sensation in the lower extremities for approximately 1 year. She reported nitrous oxide abuse over 3 years (an average of 100–200 “whippit” cartridges daily on 3 or 4 days per week), as well as long-term self-medication with oral and i.m. cyanocobalamin for the purpose of preventing nitrous oxide–induced neurologic symptoms. Results of magnetic resonance imaging (MRI) were highly suggestive of SCD, which is typically seen in primary vitamin B12 deficiency but has been reported in the context of chronic nitrous oxide exposure. Treatment was initiated with cyanocobalamin 1000 μg i.m. daily, to be continued for 5 days and followed by a four-week regimen of 1000 μg i.m. weekly. The patient was discharged after 3 days, despite continued symptoms, with instructions to obtain ongoing care but was lost to follow-up. Conclusion A patient who abused nitrous oxide chronically developed ataxia, paresthesia, and urinary retention while self-medicating with cyanocobalamin. A diagnosis of SCD was supported by MRI findings, symptoms, and the known relationship between nitrous oxide exposure and vitamin B12 deficiency.
Anterior shoulder dislocations are the most common, large joint dislocations that present to the emergency department (ED). Numerous studies support the use of intraarticular local anesthetic injections for the safe, effective, and time-saving reduction of these dislocations. Simulation training is an alternative and effective method for training compared to bedside learning. There are no commercially available ultrasound-compatible shoulder dislocation models. We utilized a three-dimensional (3D) printer to print a model that allows the visualization of the ultrasound anatomy (sonoanatomy) of an anterior shoulder dislocation. We utilized an open-source file of a shoulder, available from embodi3D® (Bellevue, WA, US). After approximating the relative orientation of the humerus to the glenoid fossa in an anterior dislocation, the humerus and scapula model was printed with an Ultimaker-2 Extended+ 3D® (Ultimaker, Cambridge, MA, US) printer using polylactic acid filaments. A 3D model of the external shoulder anatomy of a live human model was then created using Structure Sensor®(Occipital, San Francisco, CA, US), a 3D scanner. We aligned the printed dislocation model of the humerus and scapula within the resultant external shoulder mold. A pourable ballistics gel solution was used to create the final shoulder phantom. The use of simulation in medicine is widespread and growing, given the restrictions on work hours and a renewed focus on patient safety. The adage of “see one, do one, teach one” is being replaced by deliberate practice. Simulation allows such training to occur in a safe teaching environment. The ballistic gel and polylactic acid structure effectively reproduced the sonoanatomy of an anterior shoulder dislocation. The 3D printed model was effective for practicing an in-plane ultrasound-guided intraarticular joint injection. 3D printing is effective in producing a low-cost, ultrasound-capable model simulating an anterior shoulder dislocation. Future research will determine whether provider confidence and the use of intraarticular anesthesia for the management of shoulder dislocations will improve after utilizing this model.
Born from the world of product and service innovation, design thinking is gaining popularity as a method for introducing creative problem solving into the education of health professionals. Mindsets developed through practicing design thinking can help learners and educators address complex healthcare issues in a whole new way. This article aims to introduce the concepts of design thinking to the pharmacy educator, give examples of its use in pharmacy education, and discuss the value of including it in pharmacy education from both an educator and a student’s perspective. Topic: Commentary
6 August 2024 in Journal of the American College of Radiology
Background/Objectives: Accurate patient-specific dosimetry is essential for optimizing radiopharmaceutical therapy (RPT), but current tools lack validation in clinically realistic conditions. This work aimed to develop a workflow for designing and fabricating patient-derived, organ-realistic RPT phantoms and evaluate their feasibility for commissioning patient-specific RPT radioactivity quantification. Methods: We used computed tomographic (CT) and magnetic resonance (MR) imaging of representative patients, computer-aided design, and in-house 3D printing technology to design and fabricate anthropomorphic kidney and parotid phantoms with realistic organ spacing, anatomically correct orientation, and surrounding tissue heterogeneities. We evaluated the fabrication process via geometric verification (i.e., volume comparisons) and leak testing (i.e., dye penetration tests). Clinical feasibility testing involved injecting known radioactivities of 177Lu-PSMA-617 into the parotid and kidney cortex phantom chambers and acquiring SPECT/CT images. MIM SurePlan MRT SPECTRA Quant software (v7.1.2) reconstructed the acquired SPECT projections into a quantitative SPECT image and we evaluated the accuracy by region-based comparison to the known injected radioactivities and determined recovery coefficients for each organ phantom. Results: Phantom fabrication costs totaled < USD 250 and required <84 h. Geometric verification showed a slight systematic expansion (<10%) from the representative patient anatomy and leak testing confirmed watertightness of fillable chambers. Quantitative SPECT imaging systematically underestimated the injected radioactivity (mean error: −17.0 MBq; −13.2%) with recovery coefficients ranging from 0.82 to 0.93 that were negatively correlated with the surface-area-to-volume ratio. Conclusions: Patient-derived, 3D-printed fillable phantoms are a feasible, cost-effective tool to support commissioning and quality assurance for patient-specific RPT dosimetry. The results of this work will support other centers and clinics implementing patient-specific RPT dosimetry by providing the tools needed to comprehensively evaluate accuracy in clinically relevant geometries. Looking forward, widespread accurate patient-specific RPT dosimetry will improve our understanding of RPT dose response and enable personalized RPT dosing to optimize patient outcomes.