Emmanouil Liodakis

Prof. Dr. Emmanouil Liodakis

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2012 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Closed access
PDF file
MPM. Petri
M. Petri
Emmanouil LiodakisEmmanouil Liodakis
Emmanouil Liodakis
MHM. Hofmeister
M. Hofmeister
FDF. J. Despang
F. J. Despang
MMM. Maier
M. Maier
MJM. Jagodzinski
M. Jagodzinski

11 May 2011 in Skeletal Radiology
Verified
Journal Article
Closed access
PDF file
Emmanouil LiodakisEmmanouil Liodakis
Emmanouil Liodakis
IDIosifina Doxastaki
Iosifina Doxastaki
KCKongfai Chu
Kongfai Chu
CKChristian Krettek
Christian Krettek
RGRalph Gaulke
Ralph Gaulke
MKMohamed Kenawey
Mohamed Kenawey

1 November 2015 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
Emmanouil LiodakisEmmanouil Liodakis
Emmanouil Liodakis
SBStephane G. Bergeron
Stephane G. Bergeron
DZDavid J. Zukor
David J. Zukor
OHOlga L. Huk
Olga L. Huk
LELaura M. Epure
Laura M. Epure
JAJohn Antoniou
John Antoniou

1 September 2016 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
Emmanouil LiodakisEmmanouil Liodakis
Emmanouil Liodakis
JAJohn Antoniou
John Antoniou
DZDavid J. Zukor
David J. Zukor
OHOlga L. Huk
Olga L. Huk
LELaura M. Epure
Laura M. Epure
SBStephane G. Bergeron
Stephane G. Bergeron

4 October 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JHJulius Husarek
Julius Husarek
SHSilvan Hess
Silvan Hess
SRSam Razaeian
Sam Razaeian
TRThomas D. Ruder
Thomas D. Ruder
SSStephan Sehmisch
Stephan Sehmisch
Emmanouil LiodakisEmmanouil Liodakis
Emmanouil Liodakis
Conventional radiography (CR) is primarily utilized for fracture diagnosis. Artificial intelligence (AI) for CR is a rapidly growing field aimed at enhancing efficiency and increasing diagnostic accuracy. However, the diagnostic performance of commercially available AI fracture detection solutions (CAAI-FDS) for CR in various anatomical regions, their synergy with human assessment, as well as the influence of industry funding on reported accuracy are unknown. Peer-reviewed diagnostic test accuracy (DTA) studies were identified through a systematic review on Pubmed and Embase. Diagnostic performance measures were extracted especially for different subgroups such as product, type of rater (stand-alone AI, human unaided, human aided), funding, and anatomical region. Pooled measures were obtained with a bivariate random effects model. The impact of rater was evaluated with comparative meta-analysis. Seventeen DTA studies of seven CAAI-FDS analyzing 38,978 x-rays with 8,150 fractures were included. Stand-alone AI studies (n = 15) evaluated five CAAI-FDS; four with good sensitivities (> 90%) and moderate specificities (80–90%) and one with very poor sensitivity (< 60%) and excellent specificity (> 95%). Pooled sensitivities were good to excellent, and specificities were moderate to good in all anatomical regions (n = 7) apart from ribs (n = 4; poor sensitivity / moderate specificity) and spine (n = 4; excellent sensitivity / poor specificity). Funded studies (n = 4) had higher sensitivity (+ 5%) and lower specificity (-4%) than non-funded studies (n = 11). Sensitivity did not differ significantly between stand-alone AI and human AI aided ratings (p = 0.316) but specificity was significantly higher the latter group (p < 0.001). Sensitivity was significant lower in human unaided compared to human AI aided respectively stand-alone AI ratings (both p ≤ 0.001); specificity was higher in human unaided ratings compared to stand-alone AI (p < 0.001) and showed no significant differences AI aided ratings (p = 0.316). The study demonstrates good diagnostic accuracy across most CAAI-FDS and anatomical regions, with the highest performance achieved when used in conjunction with human assessment. Diagnostic accuracy appears lower for spine and rib fractures. The impact of industry funding on reported performance is small.

1 January 2011 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
MKMohamed Kenawey
Mohamed Kenawey
CKChristian Krettek
Christian Krettek
Emmanouil LiodakisEmmanouil Liodakis
Emmanouil Liodakis
RMRupert Meller
Rupert Meller
SHStefan Hankemeier
Stefan Hankemeier
Ctors for and radiologic types of insufficient bone regenerate during ISKD lengthening? Patients and Methods We analyzed 37 consecutive ISKD femoral lengthening procedures in 35 patients with a mean age 33 ± 11 years and minimum followup of 12 months (average, 27 ± 9 months; range, 12-55 months). The average length gain was 42.8 ± 12.9 mm. Results Eight patients had problems during distraction: seven had “runaway nails” and one had a nondistracting nail. Insufficient bone regenerate developed in eight patients. Important risk factors were a distraction rate greater than 1.5 mm/day (9.1 times higher risk), age 30 years or older, smoking, and lengthening greater than 4 cm. Less important risk factors identified were creation of the osteotomy at the site of previous trauma or surgery and acute correction of associated deformities. We proposed a radiologic classification for failure of bone regeneration: partial regenerate failure (Type I) or complete failure resulting in a segmental defect subdivided according to a length of 3 cm or less (Type IIa) or greater than 3 cm (Type IIb). Conclusions Distraction problems with the ISKD were related mostly to internal malfunction of the lengthening mechanism. A distraction rate greater than 1.5 mm/day should be avoided in femoral intramedullary lengthening. Smoking should be a contraindication for femoral lengthening. Level of Evidence Level II, prognostic study. See Guidelines for Authors for a complete description of levels of evidence....