Chitrlada Thongbai

Dr. Chitrlada Thongbai


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 February 2025 in Nuclear Science and Techniques
Verified
Journal Article
Closed access
PDF file
MJMonchai Jitvisate
Monchai Jitvisate
PAPittaya Apiwattanakul
Pittaya Apiwattanakul
NKNoppadol Kangrang
Noppadol Kangrang
JSJatuporn Saisut
Jatuporn Saisut
CTChitrlada Thongbai
Chitrlada Thongbai
SRSakhorn Rimjaem
Sakhorn Rimjaem

2 June 2025 in Nuclear Science and Techniques
Verified
Journal Article
Closed access
PDF file
SPSiriwan Pakluea
Siriwan Pakluea
KKKanlayaporn Kongmali
Kanlayaporn Kongmali
MJMonchai Jitvisate
Monchai Jitvisate
JSJatuporn Saisut
Jatuporn Saisut
CTChitrlada Thongbai
Chitrlada Thongbai
SRSakhorn Rimjaem
Sakhorn Rimjaem

23 March 2023 in Physica Status Solidi (a)
Verified
Journal Article
Closed access
CTChitrlada Thongbai
Chitrlada Thongbai
NKNoppadon Khangrang
Noppadon Khangrang
WJWatchara Jaikla
Watchara Jaikla
PKPitchayapak Kitisri
Pitchayapak Kitisri
KKKalayaporn Kongmali
Kalayaporn Kongmali
SSSikharin Suphakul
Sikharin Suphakul

25 June 2025 in Particles
Verified
Journal Article
Open access
PDF file
EKEkkachai Kongmon
Ekkachai Kongmon
KDKantaphon Damminsek
Kantaphon Damminsek
NKNopadon Khangrang
Nopadon Khangrang
SRSakhorn Rimjaem
Sakhorn Rimjaem
CTChitrlada Thongbai
Chitrlada Thongbai
This study presents the design and development of electromagnetic dipole magnets for use as beam dumps and spectrometers in the MIR and THz free-electron laser (FEL) beamlines at the PBP-CMU Electron Linac Laboratory (PCELL). The magnets were optimized to achieve a 60-degree bending angle for electron beams with energies up to 30 MeV, without requiring water cooling. Using CST EM Studio for 3D magnetic field simulations and ASTRA for particle tracking, the THz dipole (with 414 turns) and MIR dipole (with 600 turns) generated magnetic fields of 0.1739 T and 0.2588 T, respectively, while both operating at currents below 10 A. Performance analysis confirmed effective beam deflection, with the THz dipole showing that it was capable of handling beam energies up to 20 MeV and the MIR dipole could handle up to 30 MeV. The energy measurement at the spectrometer screen position was simulated, taking into account transverse beam size, fringe fields, and space charge effects, using ASTRA. The energy resolution, defined as the ratio of energy uncertainty to the mean energy, was evaluated for selected cases. For beam energies of 16 MeV and 25 MeV, resolutions of 0.2% and 0.5% were achieved with transverse beam sizes of 1 mm and 4 mm, respectively. All evaluated cases maintained energy resolutions below 1%, confirming the spectrometer’s suitability for high-precision beam diagnostics. Furthermore, the relationship between the initial and measured energy spread errors, taking into account a camera resolution of 0.1 mm/pixel, was evaluated. Simulations across various beam energies (10–16 MeV for the THz dipole and 20–25 MeV for the MIR dipole) confirmed that the measurement error in energy spread decreases with smaller RMS transverse beam sizes. This trend was consistent across all tested energies and magnet configurations. To ensure accurate energy spread measurements, a small initial beam size is recommended. Specifically, for beams with a narrow initial energy spread, a transverse beam size below 1 mm is essential.