Carl Frederik Werner

Dr. Carl Frederik Werner

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 July 2009 in The Journal of Physical Chemistry C
Verified
Journal Article
Closed access
JSJr. José R. Siqueira
Jr. José R. Siqueira
CWCarl Frederik Werner
Carl Frederik Werner
MBMatthias Bäcker
Matthias Bäcker
APArshak Poghossian
Arshak Poghossian
Valtencir ZucolottoValtencir Zucolotto
Valtencir Zucolotto
MSMichael Schöning
Michael Schöning

12 June 2017 in Annual Review of Analytical Chemistry
Verified
Journal Article
Closed access
Tatsuo YoshinobuTatsuo Yoshinobu
Tatsuo Yoshinobu
KMKo-Ichiro Miyamoto
Ko-Ichiro Miyamoto
CWCarl Frederik Werner
Carl Frederik Werner
APArshak Poghossian
Arshak Poghossian
TWTorsten Wagner
Torsten Wagner
MSMichael Schöning
Michael Schöning
A light-addressable potentiometric sensor (LAPS) is a semiconductor-based chemical sensor, in which a measurement site on the sensing surface is defined by illumination. This light addressability can be applied to visualize the spatial distribution of pH or the concentration of a specific chemical species, with potential applications in the fields of chemistry, materials science, biology, and medicine. In this review, the features of this chemical imaging sensor technology are compared with those of other technologies. Instrumentation, principles of operation, and various measurement modes of chemical imaging sensor systems are described. The review discusses and summarizes state-of-the-art technologies, especially with regard to the spatial resolution and measurement speed; for example, a high spatial resolution in a submicron range and a readout speed in the range of several tens of thousands of pixels per second have been achieved with the LAPS. The possibility of combining this technology with microfluidic devices and other potential future developments are discussed.

1 July 2012 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
TWTorsten Wagner
Torsten Wagner
CWCarl Frederik Werner
Carl Frederik Werner
KMKo-Ichiro Miyamoto
Ko-Ichiro Miyamoto
MSMichael Schöning
Michael Schöning
Tatsuo YoshinobuTatsuo Yoshinobu
Tatsuo Yoshinobu

6 March 2015 in Nanoscale
Verified
Journal Article
Closed access
PDF file
CWChunsheng Wu
Chunsheng Wu
TBTh Br
Th Br
APArshak Poghossian
Arshak Poghossian
CWCarl Frederik Werner
Carl Frederik Werner
MSMichael Schöning
Michael Schöning
A multi-spot (16 spots) light-addressable potentiometric sensor (MLAPS) consisting of an Al–p-Si–SiO2 structure modified with a weak polyelectrolyte layer of PAH (poly(allylamine hydrochloride)) was applied for the label-free electrical detection of DNA (deoxyribonucleic acid) immobilization and hybridization by the intrinsic molecular charge for the first time. To achieve a preferentially flat orientation of DNA strands and thus, to reduce the distance between the DNA charge and MLAPS surface, the negatively charged probe single-stranded DNAs (ssDNA) were electrostatically adsorbed onto the positively charged PAH layer using a simple layer-by-layer (LbL) technique. In this way, more DNA charge can be positioned within the Debye length, yielding a higher sensor signal. The surface potential changes in each spot induced due to the surface modification steps (PAH adsorption, probe ssDNA immobilization, hybridization with complementary target DNA (cDNA), non-specific adsorption of mismatched ssDNA) were determined from the shifts of photocurrent–voltage curves along the voltage axis. A high sensor signal of 83 mV was registered after immobilization of probe ssDNA onto the PAH layer. The hybridization signal increases from 5 mV to 32 mV with increasing the concentration of cDNA from 0.1 nM to 5 μM. In contrast, a small signal of 5 mV was recorded in the case of non-specific adsorption of fully mismatched ssDNA (5 μM). The obtained results demonstrate the potential of the MLAPS in combination with the simple and rapid LbL immobilization technique as a promising platform for the future development of multi-spot light-addressable label-free DNA chips with direct electrical readout.

30 November 2009 in Analytical Chemistry
Verified
Journal Article
Closed access
JSJr. José R. Siqueira
Jr. José R. Siqueira
RMRafael M. Maki
Rafael M. Maki
Fernando PaulovichFernando Paulovich
Fernando Paulovich
CWCarl Frederik Werner
Carl Frederik Werner
APArshak Poghossian
Arshak Poghossian
MSMichael Schöning
Michael Schöning

1 June 2013 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
UBUlrich Bohrn
Ulrich Bohrn
AMAndreas Mucha
Andreas Mucha
CWCarl Frederik Werner
Carl Frederik Werner
BTBarbara Trattner
Barbara Trattner
MBMatthias Bäcker
Matthias Bäcker
MSMichael Schöning
Michael Schöning