Sarah A. Vollam

Dr. Sarah A. Vollam


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 September 2021 in Critical Care
Verified
Journal Article
Open access
PDF file
CACarlos Areia
Carlos Areia
CBChristopher Biggs
Christopher Biggs
MSMauro Santos
Mauro Santos
NTNeal Thurley
Neal Thurley
SGStephen Gerry
Stephen Gerry
SVSarah A. Vollam
Sarah A. Vollam
Background: Timely recognition of the deteriorating inpatient remains challenging. Wearable monitoring systems (WMS) may augment current monitoring practices. However, there are many barriers to implementation in the hospital environment, and evidence describing the clinical impact of WMS on deterioration detection and patient outcome remains unclear.Objective: To assess the impact of vital-sign monitoring on detection of deterioration and related clinical outcomes in hospitalised patients using WMS, in comparison with standard care.Methods: A systematic search was conducted in August 2020 using MEDLINE, Embase, CINAHL, Cochrane Database of Systematic Reviews, CENTRAL, Health Technology Assessment databases and grey literature. Studies comparing the use of WMS against standard care for deterioration detection and related clinical outcomes in hospitalised patients were included. Deterioration related outcomes (primary) included unplanned intensive care admissions, rapid response team or cardiac arrest activation, total and major complications rate. Other clinical outcomes (secondary) included in-hospital mortality and hospital length of stay. Exploratory outcomes included alerting system parameters and clinical trial registry information.Results: Of 8706 citations, 10 studies with different designs met the inclusion criteria, of which 7 were included in the meta-analyses. Overall study quality was moderate. The meta-analysis indicated that the WMS, when compared with standard care, was not associated with significant reductions in intensive care transfers (risk ratio, RR 0.87; 95% confidence interval, CI 0.66–1.15), rapid response or cardiac arrest team activation (RR 0.84; 95% CI 0.69–1.01), total (RR 0.77; 95% CI 0.44–1.32) and major (RR 0.55; 95% CI 0.24–1.30) complications prevalence. There was also no statistically significant association with reduced mortality (RR 0.48; 95% CI 0.18–1.29) and hospital length of stay (mean difference, MD − 0.09; 95% CI − 0.43 to 0.44).Conclusion: This systematic review indicates that there is no current evidence that implementation of WMS impacts early deterioration detection and associated clinical outcomes, as differing design/quality of available studies and diversity of outcome measures make it difficult to reach a definite conclusion. Our narrative findings suggested that alarms should be adjusted to minimise false alarms and promote rapid clinical action in response to deterioration.PROSPERO Registration number:CRD42020188633.

25 June 2018 in Intensive Care Medicine
Verified
Journal Article
Open access
PDF file
SVSarah A. Vollam
Sarah A. Vollam
SDSusan Dutton
Susan Dutton
SLSallie Lamb
Sallie Lamb
TPTatjana Petrinic
Tatjana Petrinic
JYJ. Duncan Young
J. Duncan Young
PWPeter Watkinson
Peter Watkinson
Purpose Discharge from an intensive care unit (ICU) out of hours is common. We undertook a systematic review and meta-analysis to explore the association between time of discharge and mortality/ICU readmission. Methods We searched Medline, Embase, Web of Knowledge, CINAHL, the Cochrane Library and OpenGrey to June 2017. We included studies reporting in-hospital mortality and/or ICU readmission rates by ICU discharge “out-of-hours” and “in-hours”. Inclusion was limited to patients aged ≥ 16 years discharged alive from a non-specialist ICU to a lower level of hospital care. Studies restricted to specific diseases were excluded. We assessed study quality using the Newcastle Ottowa Scale. We extracted published data, summarising using a random-effects meta-analysis. Results Our searches identified 1961 studies. We included unadjusted data from 1,191,178 patients from 18 cohort studies (presenting data from 1994 to 2014). “Out of hours” had multiple definitions, beginning between 16:00 and 22:00 and ending between 05:59 and 09:00. Patients discharged out of hours had higher in-hospital mortality [relative risk (95% CI) 1.39 (1.24, 1.57) p < 0.0001] and readmission rates [1·30 (1.19, 1.42), p < 0.001] than patients discharged in hours. Heterogeneity was high (I2 90.1% for mortality and 90.2% for readmission), resulting from differences in effect size rather than the presence of an effect. Conclusions Out-of-hours discharge from an ICU is strongly associated with both in-hospital death and ICU readmission. These effects persisted across all definitions of “out of hours” and across healthcare systems in different geographical locations. Whether these increases in mortality and readmission result from patient differences, differences in care, or a combination remains unclear.

3 July 2015 in BMJ Open
Verified
Journal Article
Open access
PDF file
DCDavid A Clifton
David A Clifton
LCLei Clifton
Lei Clifton
DSDona-Maria Sandu
Dona-Maria Sandu
GSG B Smith
G B Smith
LTLionel Tarassenko
Lionel Tarassenko
PWPeter J Watkinson
Peter J Watkinson
Objectives To understand factors associated with errors using an established paper-based early warning score (EWS) system. We investigated the types of error, where they are most likely to occur, and whether ‘errors’ can predict subsequent changes in patient vital signs. Methods Retrospective analysis of prospectively collected early warning system database from a single large UK teaching hospital. Results 16 795 observation sets, from 200 postsurgical patients, were collected. Incomplete observation sets were more likely to contain observations which should have led to an alert than complete observation sets (15.1% vs 7.6%, p<0.001), but less likely to have an alerting score correctly calculated (38.8% vs 30.0%, p<0.001). Mis-scoring was much more common when leaving a sequence of three or more consecutive observation sets with aggregate scores of 0 (55.3%) than within the sequence (3.0%, p<0.001). Observation sets that ‘incorrectly’ alerted were more frequently followed by a correctly alerting observation set than error-free non-alerting observation sets (14.7% vs 4.2%, p<0.001). Observation sets that ‘incorrectly’ did not alert were more frequently followed by an observation set that did not alert than error-free alerting observation sets (73.2% vs 45.8%, p<0.001). Conclusions Missed alerts are particularly common in incomplete observation sets and when a patient first becomes unstable. Observation sets that ‘incorrectly’ alert or ‘incorrectly’ do not alert are highly predictive of the next observation set, suggesting that clinical staff detect both deterioration and improvement in advance of the EWS system by using information not currently encoded within it. Work is urgently needed to understand how best to capture this information.

15 October 2021 in Journal of Advanced Nursing
Verified
Journal Article
Open access
PDF file
CACarlos Areia
Carlos Areia
EKElizabeth King
Elizabeth King
JEJody Ede
Jody Ede
LYLouise Young
Louise Young
LTLionel Tarassenko
Lionel Tarassenko
SVSarah A. Vollam
Sarah A. Vollam
Aims: To understand current experiences of vital signs monitoring of patients and clinical staff on a surgical ward, and views on the introduction of wearable ambulatory monitoring into the general ward environment.Design: Qualitative study.Methods: Semi‐structured interviews using topic guides were conducted with 15 patients and 15 nurses on a surgical ward between July 2018 and August 2019. The concept of ambulatory wearable devices for clinical monitoring was introduced at the end of the interview.Results: Three interconnected themes were identified. Vital sign data as evidence for escalation, examined nurses' use of data to support escalation of care and the implications for patients perceived to be deteriorating who have not reached the threshold for escalation. The second theme, Trustworthiness of vital sign data, described nurses’ practice of using manual measurements to recheck or confirm automated vital signs readings when concerned. The final theme, finding a balance between continuous and intermittent monitoring, both patients and nurses agreed that although continuous monitoring may improve safety and reassurance, these needed to be balanced with multiple limitations. Factors to be considered included noise pollution, comfort, and impact on patient mobility and independence. Introduction of the concept of ambulatory wearable devices was viewed positively by both groups as offering solutions to some of the issues identified with traditional monitoring. However, most agreed that this would not be suitable for all patients and should not replace direct nurse/patient contact.Conclusion: Both patients and staff identified the benefits of continuous monitoring to improve patient safety but, due to limitations, use should be carefully considered and patient‐centred.Impact: Feedback from nurses and patients suggests there is scope for ambulatory monitoring systems to be integrated into the hospital environment; however, both groups emphasized these should not add more noise to the ward nor replace direct nursing contact.

20 April 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JDJulie Lorraine Darbyshire
Julie Lorraine Darbyshire
PGPaul R. Greig
Paul R. Greig
SVSarah A. Vollam
Sarah A. Vollam
JYJ. Duncan Young
J. Duncan Young
LHLisa Hinton
Lisa Hinton
Patients who develop intensive care unit (ICU) acquired delirium stay longer in the ICU, and hospital, and are at risk of long-term mental and physical health problems. Despite guidelines for patient assessment, risk limitation, and treatment in the ICU population, delirium and associated delusions remain a relatively common occurrence on the ICU. There is considerable information in the literature describing the incidence, suspected causes of, and discussion of the benefits and side-effects of the various treatments for delirium in the ICU. But peer-reviewed patient-focused research is almost non-existent. There is therefore a very limited understanding of the reality of delusions in the intensive care unit from the patient’s point of view. A secondary analysis of the original interviews conducted by the University of Oxford Health Experiences Research Group was undertaken to explore themes relating specifically to sleep and delirium. Patients describe a liminal existence on the ICU. On the threshold of consciousness their reality is uncertain and their sense of self is exposed. Lack of autonomy in an unfamiliar environment prompts patients to develop explanations and understandings for themselves with no foothold in fact. Patients on the ICU are perhaps more disoriented than they appear and early psychological intervention in the form of repeated orientation whilst in the ICU might improve the patient experience and defend against development of side-effects.

12 December 2019 in Nursing in Critical Care
Verified
Journal Article
Open access
PDF file
JEJody Ede
Jody Ede
EJEmma Jeffs
Emma Jeffs
SVSarah A. Vollam
Sarah A. Vollam
PWPeter Watkinson
Peter Watkinson
Background: “Failure to Rescue” includes failing to prevent avoidable patient deterioration and death. Despite its use, delays in care escalation still affect patient outcomes.Aims and Objective: The aim of this qualitative service evaluation was to map the barriers and facilitators to the escalation of care in the acute ward setting and identify those that are modifiable.Design: A total of 55 hours of qualitative observations were completed to capture care escalation events. These were conducted at two hospital sites in one National Health Service trust.Methods: Observations were iterative, with research team meetings being used to discuss the data and future methods. Field notes were analysed thematically by two researchers, extracting data on barriers and facilitators to escalation of care.Results: Clinical nursing staff challenged the sensitivity and specificity of Early Warning Scores, describing tool failings in certain clinical scenarios. Staff did not escalate based on the alerting Early Warning Scores alone but used other clinical factors, such as bleeding, which are not necessarily captured in the scoring systems. Staff frequently did not re‐escalate low‐level scores. Patient and non‐patient factors identified as posing barriers to escalation were complex care needs, patient outlier status, and involvement of multiple care teams. Factors negatively affecting the chain of communication during escalation were team tension, staffing levels, and inadequate handover.Conclusion: This service evaluation identified barriers and facilitators to the escalation of care in the acute ward setting. Unlike other studies, we found that re‐escalation or tracking of deterioration was problematic. Patients identified as being at a higher risk of escalation failure included complex patients, outliers, and patients with multiple care teams.Relevance to clinical practice: This service evaluation demonstrates continuing health care communication barriers. Patient groups (complex patients and outliers) risk process failures during escalation. This can be applied in clinical practice by staff anticipating problems in these patients, documenting clear escalation pathways.