This paper illustrates the aero-elastic optimal design, the realization and the verification of the wind tunnel scale model blades for the DTU 10 MW wind turbine model, within LIFES50+ project. The aerodynamic design was focused on the minimization of the difference, in terms of thrust coefficient, with respect to the full scale reference. From the Selig low Reynolds database airfoils, the SD7032 was chosen for this purpose and a proper constant section wing was tested at DTU red wind tunnel, providing force and distributed pressure coefficients for the design, in the Reynolds range 30-250 E3 and for different angles of attack. The aero-elastic design algorithm was set to define the optimal spanwise thickness over chord ratio (t/c), the chord length and the twist to match the first flapwise scaled natural frequency. An aluminium mould for the carbon fibre was CNC manufactured based on B-Splines CAD definition of the external geometry. Then the wind tunnel tests at Politecnico di Milano confirmed successful design and manufacturing approaches.
30 March 2017 in Journal of Energy Resources Technology
Flow characteristics of an S826 airfoil at different Reynolds numbers, ranging from 40,000–400,000 (based on airfoil chord length) and angles of attack from −10–25 degrees are thoroughly investigated in a low-speed wind tunnel. The airfoil’s lift and drag polars are first measured, and with a focus on pitching the airfoil in upstroke and downstroke orders, static stall hysteresis is identified in selected experiments at Reynolds numbers below 100,000 near the stall angle and subsequently investigated. Experiments using wire-generated free stream turbulence are conducted, and the hysteresis effects are shown to disappear when introducing a free stream turbulence of less than 2.5%. Further, spanwise flow is detected by comparing lift and drag values measured using both surface pressure integration at one cross section as well as integral force gauge measurement, and the surface oil flow visualization technique is subsequently used to study the 3D flow topologies formed on the airfoil. The formation of distinct stall cells on the suction side of the airfoil is observed at Reynolds numbers above 100,000 near the stall angle. By repeating the experiments, stall cells are proven to be reproduceable, although the identical geometries are necessarily not retained in abscence of surface impurities such as tapes. The effect of disturbances on the stall cells is investigated by utilizing roughness elements on the airfoil surface, and it is found that while such disturbances tend to change the shape of the stall cells, they do not contribute to the creation, nor destruction of the cells. Polar and visualisation measurements are also used to study flow separation, and it is observed that the separation location, as well as the laminar separation bubble, moves towards the leading edge when increasing the angle of attack.
1 May 2026 in Journal of Physics: Conference Series
A new 5×5 m 2 wind generator (WG) comprising 25 individually controlled 1 m 2 blower units has been designed, built and tested as part of the Danish FloatLab project for combined wind-wave laboratory testing of floating wind turbines (FWT). The WG targets a maximum wind speed of 5 m/s with a small-scale turbulence intensity of TI ≃ 2–3%, and is scaled at 1:70 to support the testing of a model turbine representing the IEA Wind 22 MW Reference Wind Turbine in a 20×30 m 2 wave basin. Individual servo control of all 25 fan units enables the generation of large-scale synthetic atmospheric turbulence equivalent to a 70×70 m 2 footprint at full scale, including wind shear and spatially varying turbulent fluctuations. The WG was validated through a three-stage test campaign: single-unit characterization, 2×2 array testing with harmonic loading and wind shear, and full 5×5 array testing against the targeted wind regimes NSS1–5. Hot-wire measurements at 1D and 1.5D downstream of the WG outlet confirm that the generated turbulence closely matches the theoretical Mann spectrum up to 0.1 Hz, with increased spectral decay at higher frequencies attributed to amplitude dissipation at shorter wavelengths. Compensation strategies for this dissipation are identified as a priority for future work.