Takeo Nagura

Dr. Takeo Nagura


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 December 2017 in Knee Surgery, Sports Traumatology, Arthroscopy
Verified
Journal Article
Closed access
PDF file
YNYasuo Niki
Yasuo Niki
TNTakeo Nagura
Takeo Nagura
KNKatsuya Nagai
Katsuya Nagai
SKShu Kobayashi
Shu Kobayashi
KHKengo Harato
Kengo Harato

5 April 2018 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
HTHidenori Tanikawa
Hidenori Tanikawa
RORyo Ogawa
Ryo Ogawa
KOKazunari Okuma
Kazunari Okuma
KHKengo Harato
Kengo Harato
YNYasuo Niki
Yasuo Niki
TNTakeo Nagura
Takeo Nagura
Calcium pyrophosphate dihydrate (CPPD) crystals are commonly observed in osteoarthritic joints. The aim of our study was to investigate the efficacy of a dual-energy computed tomography (DECT) for detecting CPPD crystals in knee meniscus. Twenty-six patients undergoing primary total knee arthroplasty were included in the study. Radiographs of knee joint and synovial fluid specimens were analyzed for the presence of CPPD crystals. Meniscus extracted during surgery was scanned using DECT. Sensitivity and specificity of DECT and radiograph for detecting CPPD crystals were calculated against a reference standard (polarizing light microscopy of synovial fluid aspirate). Meniscus in which CPPD crystals were suspected with DECT was further examined to confirm the crystals using a polarized microscopy. CPPD crystals in synovial fluid were observed in 9 (36%) patients. The sensitivity and specificity of DECT in the detection of CPPD crystals, against microscopic identification, were 77.8 and 93.8%, respectively. The sensitivity and specificity of conventional radiography in the detection of CPPD crystals were 44.4 and 100%, respectively. DECT was able to detect the area where CPPD crystals were deposited in the meniscus. DECT provides good diagnostic sensitivity and specificity for detection of CPPD crystals in knee meniscus as well as spatial information about CPPD crystals. DECT is currently a research tool, but we believe that DECT can be a useful instrument to diagnose CPPD deposition disease, especially for the regions where aspiration is difficult to be performed such as pubic symphysis, atlantoaxial joint, interphalangeal joint.

22 January 2019 in European Radiology Experimental
Verified
Journal Article
Open access
PDF file
DNDaisuke Nakashima
Daisuke Nakashima
KIKen Ishii
Ken Ishii
YNYuji Nishiwaki
Yuji Nishiwaki
HKHiromasa Kawana
Hiromasa Kawana
MJMasahiro Jinzaki
Masahiro Jinzaki
TNTakeo Nagura
Takeo Nagura
To predict conventional test forces (peak torque and pull-out force) and a new test force (implant stability quotient [ISQ] value of a spinal pedicle screw) from computed tomography (CT) parameters, including micro-architectural parameters, using high-resolution micro-CT and clinical multislice CT (MSCT) in human cadaveric vertebrae. Micro-CT scans before/after screw insertion (n = 68) and MSCT scans before screw insertion (n = 58) of human cadaveric vertebrae were assessed for conventional test forces and ISQ value. Three-dimensional volume position adjustment between pre-insertion micro-CT and MSCT scans and post-insertion scans (micro-CT) was performed to extract the volume of the cancellous bone surrounding the pedicle screw. The following volume bone mineral density and micro-architectural parameters were calculated: bone volume fraction, bone surface density (bone surface/total volume (BS/TV)), trabecular thickness, trabecular separation, trabecular number, structure model index, and number of nodes (branch points) of the cancellous bone network/total volume (NNd/TV) using Spearman’s rank correlation coefficient with Bonferroni correction. Conventional test forces showed the strongest correlation with BS/TV: peak torque, ρ = 0.811, p = 4.96 × 10−17(micro-CT) and ρ = 0.730, p = 7.87 × 10−11 (MSCT); pull-out force, ρ = 0.730, p = 1.64 × 10−12 (micro-CT) and ρ = 0.693, p = 1.64 × 10−9 (MSCT). ISQ value showed the strongest correlation with NNd/TV: ρ = 0.607, p = 4.01 × 10−8 (micro-CT) and ρ = 0.515, p = 3.52 × 10−5 (MSCT). Test forces, including the ISQ value, can be predicted using micro-CT and MSCT parameters. This is useful for establishing a preoperative fixation strength evaluation system.

1 January 2017 in Journal of Foot and Ankle Research
Verified
Journal Article
Open access
PDF file
TOTomohiko Ota
Tomohiko Ota
TNTakeo Nagura
Takeo Nagura
TKTetsuro Kokubo
Tetsuro Kokubo
MKMasateru Kitashiro
Masateru Kitashiro
NONaomichi Ogihara
Naomichi Ogihara
MNMasaya Nakamura
Masaya Nakamura
Background: It has been reported that hallux valgus (HV) is associated with axial rotation of the first metatarsal (1MT). However, the association between HV and torsion of the 1MT head with respect to the base has not been previously investigated. The present study examined whether there was a significant difference in 1MT torsion between HV and control groups.Methods: Three‐dimensional (3D) computed tomography (CT) scans of 39 ft were obtained, and 3D surface models of the 1MT were generated to quantify the torsion of the head with respect to the base. The HV group consisted of 27 ft from 27 women (69.5 ± 7.5 years old). Only the feet of HV patients with an HV angle >20° on weight‐bearing radiography were selected for analysis. The control group consisted of 12 ft from 12 women (67.7 ± 7.2 years old). In a virtual 3D space, two unit vectors, which describe the orientation of the 1MT head and base, were calculated. The angle formed by these two unit vectors representing 1MT torsion was compared between the control and hallux valgus groups.Results: The mean (± standard deviation) of the torsional angle of the 1MT was 17.6 (± 7.7)° and 4.7 (± 4.0)° in the HV and control groups, respectively, and the difference was significant (p < 0.01).Conclusions: This is the first study, to the best of our knowledge, to investigate 1MT torsion in HV patients using CT‐based 3D analysis. The 1MT showed significant eversion in hallux valgus patients compared to control group patients.

16 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
TSTomonori Sawada
Tomonori Sawada
HOHiroki Okawara
Hiroki Okawara
DNDaisuke Nakashima
Daisuke Nakashima
SIShuhei Iwabuchi
Shuhei Iwabuchi
MMMorio Matsumoto
Morio Matsumoto
TNTakeo Nagura
Takeo Nagura
Prolonged computer work and smartphone use can cause stiffness of the neck and shoulder muscles, including the trapezius muscle. Hence, muscle hardness quantification is clinically beneficial. The present study aimed to examine the reliability of trapezius muscle hardness measurement using a portable muscle hardness meter and ultrasound strain elastography. Overall, 20 healthy young men participated in this study. Prior to measurement, the participant’s subjective symptoms, particularly shoulder muscle stiffness, were rated using an 11-point verbal scale. Furthermore, hardness of the right and left upper trapezius muscles was assessed. In the strain elastography assessment, muscle hardness was evaluated using strain ratio. Results showed that, in quantifying upper trapezius muscle hardness, both portable muscle hardness meter and strain elastography had an excellent intra-tester reliability (>0.9). However, the correlation coefficients between muscle hardness values assessed using a muscle hardness meter and those evaluated with strain elastography did not significantly differ, and the scores for subjective shoulder stiffness did not correspond to muscle hardness values. Therefore, the hardness of the trapezius muscle does not directly reflect the subjective shoulder stiffness. Future studies should thoroughly examine the location of the shoulder stiffness, and check whether it is accompanied by local pain or tenderness.

18 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Yu IwamaYu Iwama
Yu Iwama
KHKengo Harato
Kengo Harato
SKShu Kobayashi
Shu Kobayashi
YNYasuo Niki
Yasuo Niki
NONaomichi Ogihara
Naomichi Ogihara
TNTakeo Nagura
Takeo Nagura
Although the external knee adduction moment (KAM) during gait was shown to be a quantitative parameter of medial knee osteoarthritis (OA), it requires expensive equipment and a dedicated large space to measure. Therefore, it becomes a major reason to limit KAM measurement in a clinical environment. The purpose of this study was to estimate KAM using a single inertial measurement unit (IMU) during gait in patients with knee OA. A total of 22 medial knee OA patients (44 knee joints) performed conventional gait analysis using three-dimensional (3D) motion capture system. At the same time, we attached commercial IMUs to six body segments (sternum, pelvis, both thighs, and both shanks), and IMU signals during gait were recorded synchronized with the motion capture system. The peak-to-peak difference of acceleration in the lateral/medial axis immediately after heel contact was defined as the thrust acceleration (TA). We hypothesized that TA would represent the lateral thrust of the knee during the stance phase and correlate with the first peak of KAM. The relationship between the peak KAM and TA of pelvis (R = 0.52, p < 0.001), shanks (R = 0.57, p < 0.001) and thighs (R = 0.49, p = 0.001) showed a significant correlation. The root mean square error (RMSE) of linear regression models of pelvis, shanks, and thighs to estimate KAM were 0.082, 0.079, and 0.084 Nm/(kg·m), respectively. Our newly established parameter TA showed a moderate correlation with conventional KAM. The current study confirmed our hypothesis that a single IMU would predict conventional KAM during gait. Since KAM is known as an indicator for prognosis and severity of knee OA, this new parameter has the potential to become an accessible predictor for medial knee OA instead of KAM.