Michael Oelze

Dr. Michael Oelze

orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 January 2016 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
MOMichael Oelze
Michael Oelze
JMJonathan Mamou
Jonathan Mamou
Conventional medical imaging technologies, including ultrasound, have continued to improve over the years. For example, in oncology, medical imaging is characterized by high sensitivity, i.e., the ability to detect anomalous tissue features, but the ability to classify these tissue features from images often lacks specificity. As a result, a large number of biopsies of tissues with suspicious image findings are performed each year with a vast majority of these biopsies resulting in a negative finding. To improve specificity of cancer imaging, quantitative imaging techniques can play an important role. Conventional ultrasound B-mode imaging is mainly qualitative in nature. However, quantitative ultrasound (QUS) imaging can provide specific numbers related to tissue features that can increase the specificity of image findings leading to improvements in diagnostic ultrasound. QUS imaging can encompass a wide variety of techniques including spectral-based parameterization, elastography, shear wave imaging, flow estimation, and envelope statistics. Currently, spectral-based parameterization and envelope statistics are not available on most conventional clinical ultrasound machines. However, in recent years, QUS techniques involving spectral-based parameterization and envelope statistics have demonstrated success in many applications, providing additional diagnostic capabilities. Spectral-based techniques include the estimation of the backscatter coefficient (BSC), estimation of attenuation, and estimation of scatterer properties such as the correlation length associated with an effective scatterer diameter (ESD) and the effective acoustic concentration (EAC) of scatterers. Envelope statistics include the estimation of the number density of scatterers and quantification of coherent to incoherent signals produced from the tissue. Challenges for clinical application include correctly accounting for attenuation effects and transmission losses and implementation of QUS on clinical devices. Successful clinical and preclinical applications demonstrating the ability of QUS to improve medical diagnostics include characterization of the myocardium during the cardiac cycle, cancer detection, classification of solid tumors and lymph nodes, detection and quantification of fatty liver disease, and monitoring and assessment of therapy.

1 December 2012 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
GGGoutam Ghoshal
Goutam Ghoshal
RLRoberto J. Lavarello
Roberto J. Lavarello
JKJeremy P. Kemmerer
Jeremy P. Kemmerer
RMRita J. Miller
Rita J. Miller
MOMichael Oelze
Michael Oelze

10 May 2019 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
Gun KimGun Kim
Gun Kim
VLVivian Lau
Vivian Lau
AHAbigail J. Halmes
Abigail J. Halmes
MOMichael Oelze
Michael Oelze
JMJeffrey S. Moore
Jeffrey S. Moore
KLKing C. Li
King C. Li
While study in the field of polymer mechanochemistry has yielded mechanophores that perform various chemical reactions in response to mechanical stimuli, there is not yet a triggering method compatible with biological systems. Applications such as using mechanoluminescence to generate localized photon flux in vivo for optogenetics would greatly benefit from such an approach. Here we introduce a method of triggering mechanophores by using high-intensity focused ultrasound (HIFU) as a remote energy source to drive the spatially and temporally resolved mechanical-to-chemical transduction of mechanoresponsive polymers. A HIFU setup capable of controlling the excitation pressure, spatial location, and duration of exposure is employed to activate mechanochemical reactions in a cross-linked elastomeric polymer in a noninvasive fashion. One reaction is the chromogenic isomerization of a naphthopyran mechanophore embedded in a polydimethylsiloxane (PDMS) network. Under HIFU irradiation evidence of the mechanochemical transduction is the observation of a reversible color change as expected for the isomerization. The elastomer exhibits this distinguishable color change at the focal spot, depending on ultrasonic exposure conditions. A second reaction is the demonstration that HIFU irradiation successfully triggers a luminescent dioxetane, resulting in localized generation of visible blue light at the focal spot. In contrast to conventional stimuli such as UV light, heat, and uniaxial compression/tension testing, HIFU irradiation provides spatiotemporal control of the mechanochemical activation through targeted but noninvasive ultrasonic energy deposition. Targeted, remote light generation is potentially useful in biomedical applications such as optogenetics where a light source is used to trigger a cellular response.

19 January 2022 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
PDF file
Gun KimGun Kim
Gun Kim
QWQiong Wu
Qiong Wu
JCJames L. Chu
James L. Chu
ESEmily J. Smith
Emily J. Smith
MOMichael Oelze
Michael Oelze
KLKing C. Li
King C. Li
Mechanophores are molecular motifs that respond to mechanical perturbance with targeted chemical reactions toward desirable changes in material properties. A large variety of mechanophores have been investigated, with applications focusing on functional materials, such as strain/stress sensors, nanolithography, and self-healing polymers, among others. The responses of engineered mechanophores, such as light emittance, change in fluorescence, and generation of free radicals (FRs), have potential for bioimaging and therapy. However, the biomedical applications of mechanophores are not well explored. Herein, we report an in vitro demonstration of an FR-generating mechanophore embedded in biocompatible hydrogels for noninvasive cancer therapy. Controlled by high-intensity focused ultrasound (HIFU), a clinically proven therapeutic technique, mechanophores were activated with spatiotemporal precision to generate FRs that converted to reactive oxygen species (ROS) to effectively kill tumor cells. The mechanophore hydrogels exhibited no cytotoxicity under physiological conditions. Upon activation with HIFU sonication, the therapeutic efficacies in killing in vitro murine melanoma and breast cancer tumor cells were comparable with lethal doses of H2O2. This process demonstrated the potential for mechanophore-integrated HIFU combination as a noninvasive cancer treatment platform, named “mechanochemical dynamic therapy” (MDT). MDT has two distinct advantages over other noninvasive cancer treatments, such as photodynamic therapy (PDT) and sonodynamic therapy (SDT). 1) MDT is ultrasound based, with larger penetration depth than PDT. 2) MDT does not rely on sonosensitizers or the acoustic cavitation effect, both of which are necessary for SDT. Taking advantage of the strengths of mechanophores and HIFU, MDT can provide noninvasive treatments for diverse cancer types. Significance Biomedical application of mechanophores is the next frontier in polymer mechanochemistry. We report the concept, mechanochemical dynamic therapy (MDT), that utilizes remote, ultrasound-triggered mechanophore activation to enable anticancer activities. We selected an azo-based mechanophore to generate reactive free radicals (FRs) under the control of high-intensity focused ultrasound (HIFU), which subsequently produced ROS. We investigated two sets of in vitro mouse cancer models: 1) melanoma (B16F10) and 2) breast cancer (E0771). Inhibition of growth and decreases in viabilities of both B16F10 and E0771 were observed in correlation to the release of ROS by mechanophore activation. By circumventing the known issues in photodynamic therapy and sonodynamic therapy, we anticipate MDT to be a powerful anticancer tool complementary to other existing cancer treatments.

1 April 2024 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
ZKZhengchang Kou
Zhengchang Kou
MLMatthew R. Lowerison
Matthew R. Lowerison
QYQi You
Qi You
YWYike Wang
Yike Wang
PSPengfei Song
Pengfei Song
MOMichael Oelze
Michael Oelze
To improve the spatial resolution of power Doppler (PD) imaging, we explored null subtraction imaging (NSI) as an alternative beamforming technique to delay-and-sum (DAS). NSI is a nonlinear beamforming approach that uses three different apodizations on receive and incoherently sums the beamformed envelopes. NSI uses a null in the beam pattern to improve the lateral resolution, which we apply here for improving PD spatial resolution both with and without contrast microbubbles. In this study, we used NSI with three types of singular value decomposition (SVD)-based clutter filters and noise equalization to generate high-resolution PD images. An element sensitivity correction scheme was also proposed as a crucial component of NSI-based PD imaging. First, a microbubble trace experiment was performed to evaluate the resolution improvement of NSI-based PD over traditional DAS-based PD. Then, both contrast-enhanced and contrast free ultrasound PD images were generated from the scan of a rat brain. The cross-sectional profile of the microbubble traces and microvessels were plotted. FWHM was also estimated to provide a quantitative metric. Furthermore, iso-frequency curves were calculated to provide a resolution evaluation metric over the global field of view. Up to six-fold resolution improvement was demonstrated by the FWHM estimate and four-fold resolution improvement was demonstrated by the iso-frequency curve from the NSI-based PD microvessel images compared to microvessel images generated by traditional DAS-based beamforming. A resolvability of $39~\mu \text{m}$ was measured from the NSI-based PD microvessel image. The computational cost of NSI-based PD was only increased by 40 percent over the DAS-based PD.

16 October 2018 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
AAAnil Agarwal
Anil Agarwal
JRJonathan Reeg
Jonathan Reeg
APAnthony S. Podkowa
Anthony S. Podkowa
MOMichael Oelze
Michael Oelze
In ultrasonic imaging, reduction of lateral sidelobes can result in an improved image with less distortion and fewer artifacts. In general, apodization is used to lower sidelobes in exchange for increasing the width of the mainlobe and thus decreasing lateral resolution. Null subtraction imaging (NSI) is a nonlinear image processing technique that uses different receive apodizations on copies of the same RF data to maintain low sidelobe levels while simultaneously improving lateral resolution. The images created with three different apodization functions are combined to form an image with low sidelobe levels and apparent improvements in lateral resolution compared to conventional rectangular apodization. To evaluate the performance of this technique for different imaging tasks, experiments were performed on an ATS539 phantom containing wire targets to assess lateral resolution and cylindrical anechoic and hyperechoic targets to assess contrast. NSI images were compared against rectangular apodized images and minimum variance (MV) beamformed images. In experiments, the apparent lateral resolution was observed to improve by a factor of more than 35 times when compared to rectangular apodization. Image quality was assessed by estimation of lateral resolution (-6-dB receive beamwidth), mainlobe to sidelobe ratio (MSR) and contrast-to-noise ratio (CNR). Imaging with NSI using a focal number of 2 (f/2), the -6- dB beamwidth on receive as measured from a small wire target in the ATS phantom was 0.03λ compared to 2.79λ for rectangular apodization. Sidelobes were observed to decrease by 32.9 dB with NSI compared to rectangular apodization. However, the ability to observe the contrast of anechoic and hyperechoic targets reduced when utilizing the NSI scheme, i.e., the CNR decreased from -3.05 to -1.01 for anechoic targets and 1.65 to 0.45 for the hyperechoic targets.