Because of the minimal demand for cooperation by the subject, the forced oscillation technique is increasingly employed in routine lung function testing. However, comprehensive and device-independent values of respiratory impedance at baseline and after bronchodilation have not been established for healthy adults.The aim of this multicentre study was to collect impedance data from 4 to 26 Hz in healthy Caucasian subjects between 18 and 80 years of age. Five different devices were employed to assess baseline values and the bronchodilator response.Altogether, 368 subjects were examined. Despite adjustment for anthropometry, the impedance spectra differed in frequency dependence between the centres, and hence could not be pooled. However, resistance at all frequencies except 20 and 25 Hz, and the low-frequency (≤14 Hz) values of reactance did not exhibit a centre dependence. The regression equations for resistance reflected a greater height dependence in males and a greater weight dependence in both males and females than those published previously. Bronchodilation resulted in a statistically significant decrease (11%) in resistance and a 95th percentile equal to a 32% decrease in resistance at low frequency.We conclude that rigorous calibration procedures should be developed to ensure data compatibility. Furthermore, new reference equations based on different setups are recommended to replace those established with a single device.
BACKGROUND: During the menstrual cycle the endometrium undergoes cyclic proliferative and secretory changes in preparation for implantation. If this preparation is not sufficient, then implantation will fail. The impact of endometrial thickness on the day of embryo transfer on IVF outcome was investigated in the present study. METHODS: A retrospective analysis was conducted of 1228 IVF/ICSI cycles. Stimulation was with clomiphene citrate (CC) + hMG in one‐third of the cycles, and ultrashort GnRH agonist stimulation in two‐thirds. Cycle parameters were compared between pregnant and non‐pregnant patients. A similar comparison was made between ongoing pregnancies and those that resulted in a loss. RESULTS: There were more follicles, oocytes and embryos, the endometrium was thicker and the embryo quality was higher among women who became pregnant when compared with non‐pregnant women after assisted reproduction. The pregnancy rate improved as endometrial thickness increased. No difference in cycle parameters and endometrial thickness was found between ongoing pregnancies and pregnancies that resulted in a first‐trimester loss. CC had no measurable adverse endometrial effect, but the pregnancy rate was lower in CC+hMG cycles. CONCLUSIONS: Increased endometrial thickness is associated with higher pregnancy rates. However, neither attainment of pregnancy nor pregnancy outcome was predicted by endometrial thickness alone.
1 July 2007 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
Background: The laryngeal mask airway (LMA) has been advocated as an alternative technique to tracheal intubation for airway management of children with recent upper respiratory tract infections (URIs). The authors determined the occurrence of adverse respiratory events and identified the associated risk factors to assess the safety of LMA in children. Methods: During a period of 5 months, parents of children scheduled to undergo general anesthesia with an LMA were asked to fill out a questionnaire regarding their child's medical history and potential symptoms of URI. In addition, all episodes of adverse respiratory events in the perioperative period (laryngospasm, bronchospasm, coughing, airway obstruction, and oxygen desaturation) as well as details of anesthesia management were recorded. Results: Among the 831 children included in the study, 27% presented with a history of a recent URI within the last 2 weeks before anesthesia. The presence of a recent URI doubled the incidence of laryngospasm (odds ratio, 2.6; 95% confidence interval, 1.3-5.0), coughing (odds ratio, 2.7; 95% confidence interval, 1.7-4.3), and oxygen desaturation (odds ratio, 1.9; 95% confidence interval, 1.2-2.8). This incidence was even higher in young children; in those undergoing ear, nose, and throat surgery; and when there were multiple attempts to insert the LMA. Conclusion: An LMA used in children with recent URIs was associated with a higher incidence of laryngospasm, cough, and oxygen desaturation compared with healthy children. However, the overall incidence of adverse respiratory events was low, suggesting that if anesthesiologists allow at least a 2-week interval after a URI, they can safely proceed with anesthesia using an LMA.