Martin Maerz

Prof. Dr. Martin Maerz

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 July 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Open access
SEStefan Ehrlich
Stefan Ehrlich
HRHans Rossmanith
Hans Rossmanith
MSMarco Sauer
Marco Sauer
CJChristopher Joffe
Christopher Joffe
MMMartin Maerz
Martin Maerz
This paper presents a fast numerical calculation method of realistic power losses for high frequency litz wires. Explicitly, the imperfect structure of litz wires is considered when calculating losses due to an excitation current (skin losses) and external magnetic fields (proximity losses). Calculations of litz wires with more than 1000 strands were performed on a personal computer and have been validated by measurements up to 10 MHz. In the calculation, the impact of the bundle structure on skin and proximity losses is examined. The method allows to select a suitable litz wire for a specific application or to design a litz wire considering realistic twisting structures.

17 February 2022 in Ultramicroscopy
Verified
Journal Article
Open access
BFBirk Fritsch
Birk Fritsch
MWMingjian Wu
Mingjian Wu
AHAndreas Hutzler
Andreas Hutzler
DZDan Zhou
Dan Zhou
RSRonald Spruit
Ronald Spruit
ESErdmann Spiecker
Erdmann Spiecker
In situ TEM utilizing windowed gas cells is a promising technique for studying catalytic processes, wherein temperature is one of the most important parameters to be controlled. Current gas cells are only capable of temperature measurement on a global (mm) scale, although the local temperature at the spot of observation (µm to nm scale) may significantly differ. Thus, local temperature fluctuations caused by gas flow and heat dissipation dynamics remain undetected when solely relying on the global device feedback. In this study, we overcome this limitation by measuring the specimen temperature in situ utilizing parallel-beam electron diffraction at gold nanoparticles. By combining this technique with an advanced data processing algorithm, we achieve sub-Kelvin precision in both, vacuum as well as gaseous environments. Mitigating charging effects is furthermore shown to minimize systematic errors. By utilizing this method, we characterize the local thermal stability of a state-of-the-art gas cell equipped with heating capability in vacuum and under various gas-flow conditions. Our findings provide crucial reference for in situ investigations into catalysis.

3 May 2025 in Drones
Verified
Journal Article
Open access
PDF file
LSLeon Seidel
Leon Seidel
SGSimon Gehringer
Simon Gehringer
TRTobias Raczok
Tobias Raczok
SISven-Nicolas Ivens
Sven-Nicolas Ivens
BEBernd Eckardt
Bernd Eckardt
MMMartin Maerz
Martin Maerz
Early wildfire detection is critical for effective suppression efforts, necessitating rapid alerts and precise localization. While computer vision techniques offer reliable fire detection, they often lack contextual understanding. This paper addresses this limitation by utilizing Vision Language Models (VLMs) to generate structured scene descriptions from Unmanned Aerial Vehicle (UAV) imagery. UAV-based remote sensing provides diverse perspectives for potential wildfires, and state-of-the-art VLMs enable rapid and detailed scene characterization. We evaluated both cloud-based (OpenAI, Google DeepMind) and open-weight, locally deployed VLMs on a novel evaluation dataset specifically curated for understanding forest fire scenes. Our results demonstrate that relatively compact, fine-tuned VLMs can provide rich contextual information, including forest type, fire state, and fire type. Specifically, our best-performing model, ForestFireVLM-7B (fine-tuned from Qwen2-5-VL-7B), achieved a 76.6% average accuracy across all categories, surpassing the strongest closed-weight baseline (Gemini 2.0 Pro at 65.5%). Furthermore, zero-shot evaluation on the publicly available FIgLib dataset demonstrated state-of-the-art smoke detection accuracy using VLMs. Our findings highlight the potential of fine-tuned, open-weight VLMs for enhanced wildfire situational awareness via detailed scene interpretation.

16 October 2023 in IEEE Transactions on Power Electronics
Verified
Journal Article
Open access
TLThomas Lehmeier
Thomas Lehmeier
AAAdrian Amler
Adrian Amler
YZYan Zhou
Yan Zhou
MMMartin Maerz
Martin Maerz
Soft-switching in power inverters for drive and grid applications can both enhance the efficiency by reducing switching losses and improve electromagnetic interference (EMI) due to lower switching speeds with their associated $\mathrm{d}v/\mathrm{d}t$ . An advantageous topology is the well-known auxiliary resonant commutated pole (ARCP) inverter. The development of such power electronic inverters often focuses on reducing weight, volume, and cost. Considering a three-phase ARCP system, this article presents a novel single shared inductor $(\mathrm{S}^{2}\mathrm{I})$ -ARCP approach to reduce the passive component count in the auxiliary circuit from three to one. The simultaneous use of the shared inductor by more than one phase must be detected and avoided by the control algorithm. A frequency analysis of such occurrences is performed, and a method for avoiding them by shifting the switching edges is presented. The proposed $\mathrm{S}^{2}\mathrm{I}$ -ARCP topology together with an appropriate control algorithm is implemented and validated at 10 kW with an 800 V dc-link. Efficiency measurement results indicated a significant loss reduction under soft-switching operation by more than 38% compared with hard-switching, with a peak efficiency value of 99.58%. It is demonstrated that a mere adjustment in the control signal generation can save two resonant inductors without significant disadvantages.

15 February 2024 in International Journal of Mechanical Sciences
Verified
Journal Article
Open access
DZDawei Zhao
Dawei Zhao
SLSebastian Letz
Sebastian Letz
MJMichael Jank
Michael Jank
MMMartin Maerz
Martin Maerz

13 March 2023 in Aerospace
Verified
Journal Article
Open access
PDF file
Markus MeindlMarkus Meindl
Markus Meindl
CRCor de Ruiter
Cor de Ruiter
VMValerio Marciello
Valerio Marciello
MSMario Di Stasio
Mario Di Stasio
FHFlorian Hilpert
Florian Hilpert
MMMartin Maerz
Martin Maerz
Sustainability and, especially, emission reductions are significant challenges for airports currently being addressed. The Clean Sky 2 project GENESIS addresses the environmental sustainability of hybrid-electric 50-passenger aircraft systems in a life cycle perspective to support the development of a technology roadmap for the transition to sustainable and competitive electric aircraft systems. This article originates from the GENESIS research and describes various options for ground power supply at a regional airport. Potential solutions for airport infrastructure with a short (2030), medium (2040) and long (2050) time horizon are proposed. This analysis includes estimating the future energy demand per day, month and year. In addition, the current flight plan based on conventional aircraft is adapted to the needs of a 50-PAX regional aircraft. Thus, this article provides an overview of the energy demand of a regional airport, divided into individual time horizons.