Paola Grazia Pittoni

Dr. Paola Grazia Pittoni

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2013 in Colloids and Surfaces A: Physicochemical and Engineering Aspects
Verified
Journal Article
Closed access
PPPaola Grazia Pittoni
Paola Grazia Pittoni
CCChiang-Ching Chang
Chiang-Ching Chang
TYTeng-Shiang Yu
Teng-Shiang Yu
SLShi-Yow Lin
Shi-Yow Lin

29 July 2014 in Langmuir
Verified
Journal Article
Closed access
PPPaola Grazia Pittoni
Paola Grazia Pittoni
CLChia-Hui Lin
Chia-Hui Lin
TYTeng-Shiang Yu
Teng-Shiang Yu
SLShi-Yow Lin
Shi-Yow Lin


1 April 2015 in Experimental Thermal and Fluid Science
Verified
Journal Article
Closed access
PPPaola Grazia Pittoni
Paola Grazia Pittoni
YLYa-Chi Lin
Ya-Chi Lin
RWRen-Jing Wang
Ren-Jing Wang
TYTeng-Shiang Yu
Teng-Shiang Yu
SLShi-Yow Lin
Shi-Yow Lin

1 November 2012 in Journal of the Taiwan Institute of Chemical Engineers
Verified
Journal Article
Closed access
PPPaola Grazia Pittoni
Paola Grazia Pittoni
YCYao-Yuan Chang
Yao-Yuan Chang
SLShi-Yow Lin
Shi-Yow Lin

18 November 2021 in Fluids
Verified
Journal Article
Open access
PDF file
ALAndrea Lucchini
Andrea Lucchini
ICIgor Matteo Carraretto
Igor Matteo Carraretto
TPThanh N. Phan
Thanh N. Phan
PPPaola Grazia Pittoni
Paola Grazia Pittoni
LCLuigi Pietro Maria Colombo
Luigi Pietro Maria Colombo
Environmental concerns are forcing the replacement of commonly used refrigerants, and finding new fluids is a top priority. Soon the R134a will be banned, and the hydro-fluoro-olefin (HFO) R1234ze(E) has been indicated as an alternative due to its smaller global warming potential (GWP) and shorter atmospheric lifetime. Nevertheless, for an optimal replacement, its thermo-fluid-dynamic characteristics have to be assessed. Flow boiling experiments (saturation temperature Tsat = 5 °C, mass flux G = 65 ÷ 222 kg·m−2·s−1, mean quality xm = 0.15 ÷ 0.95, quality changes ∆x = 0.06 ÷ 0.6) inside a microfin tube were performed to compare the pressure drop per unit length and the heat transfer coefficient provided by the two fluids. The results were benchmarked for some correlations. In commonly adopted operating conditions, the two fluids show a very similar behavior, while benchmark showed that some correlations are available to properly predict the pressure drop for both fluids. However, only one is satisfactory for the heat transfer coefficient. In conclusion, R1234ze(E) proved to be a suitable drop-in replacement for the R134a, whereas further efforts are recommended to refine and adapt the available predictive models.