Kristen E Holmes

Dr. Kristen E Holmes


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 April 2025 in Sensors
Verified
Journal Article
Open access
PDF file
GGGregory Grosicki
Gregory Grosicki
FFFinnbar Fielding
Finnbar Fielding
JKJeongeun Kim
Jeongeun Kim
CCChristopher Chapman
Christopher Chapman
MOMARIA OLARU
MARIA OLARU
KHKristen E Holmes
Kristen E Holmes
Wearable devices are increasingly used for health monitoring, yet the impact of consistent wear on physiological and behavioral outcomes is unclear. Leveraging nearly a million days and nights of longitudinal data from 11,914 subscribers, we examined the associations between the frequency of wearing a wrist-worn wearable device (WHOOP Inc., Boston, MA, USA) and 12-week changes in biometric, sleep, and activity profiles, modeling both between- and within-person effects. Higher average wear frequency and week-to-week increases in wear were associated with a lower resting heart rate (RHR), higher heart rate variability (HRV), longer and more consistent sleep, and greater weekly and daily physical activity duration (Ps < 0.01). A within-person multiple mediation analysis indicated that increased sleep duration partially mediated the association between wear frequency and a standardized (z-scored) RHR (indirect effect = −0.0387 [95% CI: −0.0464, −0.0326]), whereas physical activity minutes did not (indirect effect = 0.0003 [95% CI: −0.0036, 0.0040]). A Granger causality analysis revealed a modest but notable association between prior wear frequency and future RHR in participants averaging ≤5 days of weekly wear (p < 0.05 in 10.92% of tests). While further research is needed, our findings provide real-world evidence that sustained wearable engagement may support healthier habits and improved physiological outcomes over time.

13 March 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
GGGregory Grosicki
Gregory Grosicki
FFFinnbar Fielding
Finnbar Fielding
JKJeongeun Kim
Jeongeun Kim
CCChristopher Chapman
Christopher Chapman
MOMARIA OLARU
MARIA OLARU
KHKristen E Holmes
Kristen E Holmes
Wearable devices are increasingly used for health monitoring, yet the impact of consistent wear on physiological and behavioral outcomes is unclear. Leveraging nearly a million days and nights of longitudinal data from 11,914 subscribers, we examined associations between the frequency of wearing a wrist-worn wearable device (WHOOP Inc., Boston, MA) and 12-week changes in biometric, sleep, and activity profiles, modeling both between and within-person effects. Higher average wear frequency, and week-to-week increases in wear, were associated with lower resting heart rate (RHR), higher heart rate variability (HRV), longer and more consistent sleep, and greater weekly and daily physical activity duration (Ps< 0.01). A within-person multiple mediation analysis indicated that increased sleep duration partially mediated the association between wear frequency and standardized (z-scored) RHR (indirect effect = -0.0387 [95% CI: -0.0464, -0.0326]), whereas physical activity minutes did not (indirect effect = 0.0003 [95% CI: -0.0036, 0.0040]). Granger causality analysis revealed a modest but notable association between prior wear frequency and future RHR in participants averaging ≤5 days of weekly wear (P< 0.05 in 10.92% of tests). While further research is needed, our findings provide real-world evidence that sustained wearable engagement may support healthier habits and improved physiological outcomes over time.

1 April 2025 in medRxiv
Verified
Preprint
Open access
PDF file
GGGregory J. Grosicki
Gregory J. Grosicki
WHWilliam von Hippel
William von Hippel
FFFinnbar Fielding
Finnbar Fielding
JKJeongeun Kim
Jeongeun Kim
CCChristopher Chapman
Christopher Chapman
KHKristen E Holmes
Kristen E Holmes
Purpose: Consistently performing at the highest level in golf requires a complex interplay of physiological and psychological attributes, with success often defined by razor-thin margins. Sleep characteristics and cardiac autonomic function, reflected by resting heart rate (RHR) and heart rate variability (HRV), are key indicators of recovery and readiness to perform. Yet, their relevance to elite golf performance remains largely unexplored. Methods: We analyzed wearable-derived longitudinal data from 389 professional tour-level golfers across 521 competitive events (2017-2025), encompassing 35,140 nights of sleep and biometric monitoring. Key metrics included sleep duration (7.2±0.7hrs), sleep consistency (69.1 ± 6.9%), RHR (55.9 ± 7.9bpm), HRV (64.2±28.1ms), and a composite Recovery score (59.1±9.9%). Golf performance (total score, great shots, poor shots, strokes gained) was extracted from a subscription-based database. Linear mixed-effects models assessed both between-person differences and within-person season-to-season changes, adjusting for age (34.1 ± 9.1yrs), height (1.81 ± 0.07m), and weight (83.2 ± 10.6kg). Results: Golfers with superior sleep and biometric profiles consistently performed better, both between and within individuals (Ps<0.05). Between individuals, each additional hour of sleep was associated with a lower score (b=-0.522), as was a 10-percentage point increase in sleep consistency (b=-0.382), a 1bpm lower RHR (b=-0.038), and a 10-percentage point increase in Recovery (b=-0.476). Within athletes, season-to-season improvements in sleep consistency (b=-0.193 per 10-percentage points), HRV (b=-0.016 per 1ms), and Recovery (b=-0.238 per 10 percentage points) were also associated with lower scores (Ps<0.05). Conclusions: Sleep and measures of cardiac autonomic function are associated with performance in elite golf. Both individual differences and within-athlete improvements were linked to success, highlighting the potential role of sleep, resting heart rate, and heart rate variability in optimizing performance at the highest level of sport.